Battery Operated Carbon Monoxide Alarm Part Number 9CO5 Model KN-COB-B Architectural and Engineering Specifications The carbon monoxide alarm shall be...
How can I shut off my Kidde carbon monoxide detector when beeping..carbon monoxide alaram is keep biping Check your user manual for issues dealing
Manual P/N 21008094 Rev C 8 /12 2529-7209-01 ... Carbon Monoxide Alarm User’s Guide Models: ... This carbon monoxide alarm is not a substitute for installing and
Manual P/N 820-1388 Rev. C 07-12 ... This carbon monoxide alarm is designed to detect carbon monoxide from ... This carbon monoxide alarm requires a
Carbon Monoxide Alarm User’s Manual ... Carbon monoxide is a colorless, ... This carbon monoxide alarm is designed to detector carbon monoxide gas from ANY source
USER’S MANUAL Smoke & Carbon Monoxide Alarm AC Powered Smoke & ... keep carbon monoxide or smoke from reaching the Alarm. Installing Smoke/CO Alarms in Mobile Homes
Welcome Note: Many times throughout this User Guide, we will refer to Carbon Monoxide as “CO”. This Kidde carbon monoxide (CO) alarm is an important part of your
Carbon Monoxide Alarm User’s Guide Model: KN-COPP-3 ... Carbon monoxide is a colorless, ... Periodically review this alarm manual and discuss your CO alarm emer-
Carbon Monoxide Alarm User’s Guide Models: ... Carbon monoxide is a colorless, ... Periodically review this alarm manual and discuss your CO alarm emer-
Carbon Monoxide and Explosive Gas Alarm User’s Guide ... RESIDENTIAL GAS DETECTOR 2509-7214-01 ... Periodically review this alarm manual and discuss your CO alarm emer-
Satellite monitoring for carbon monoxide and particulate matter during forest fire ... 10-Mar 49 178 244 1.3 1.7 episode, ... 14-Mar 107 165 228 1.3 1.4 episode,
INSTRUCTOR GUIDE TOPIC: FIRE DEPARTMENT RESPONSE TO CARBON MONOXIDE INCIDENTS TIME REQUIRED: 2 TO 3 HOURS MATERIALS: Baltimore County Fire Department SOP for Carbon
SimpliSafe CO Detector Owners Manual (Revision SSCO1-A) 1 / 4 December 2012 Carbon Monoxide Detector Manual (SSCO1) Introduction The SSCO1 wireless carbon monoxide
CO1224 Carbon Monoxide Detector ... NOTICE: This manual shall be left with the owner/user of ... be replaced with a new System Sensor carbon monoxide detector
Carbon Monoxide Detector Manual (SSCO1) ... Periodically review this alarm manual and discuss your CO ... This carbon monoxide alarm is not a substitute for installing
Specifications subject to change without notice. | USA 140924 | Page 1 of 6 1200 Stowe ie Suite 100 Powa, A 92064 | Ph 5 5. . TEC | eeantsoutions.cointeccontos
vol-ii(ts) e8-battery & battery charger page 2 of 22 table of contents of battery & battery charger no description
BATTERY BUSINESS How to make ... Anyway, after you have your batteries take them home and recondition them using the ... can recondition various batteries and name
Sep 7, 2016 ... It makes use of the BionX BBI E-Bike Test System (a valid license from BionX is required). Now, BionX batteries can be tested by connecting the BBI-2 interface and running the software to keep the battery active. Then the test can by
Datasheet Solenoid valves 2/2-way servo operated type EV220B 15 50 ... FKM or NBR. IC.PD.200.D6.02 / 520B4537 4 Solenoid valves,
Sep 20, 2013 ... Control operates to a +/- 1°F accuracy. •. Powered from the chiller 24 volt control circuit. No high voltage interference. •. 1 or 2 compressor control capability. •. Operates and displays in °F and °C. •. Controls chiller on inlet o
Fire Alarm, Water Flow Alarm, & Signaling Systems: D-03 January 1, 2017 2 6. Completeness of Shop Drawings: Provide a scaled floor plan showing the location of all
02/17 Mass: 18 Kg Mass: 39,5 Kg DPH-4 ISO 4401: 2005 Mounting surface: 4401-08-08-0-05 Fastening bolts: 6 socket head screws M12x60 class 12.9 Tightening torque = 125 Nm
1.0 Introduction The Duo-Chek® Engine Coolant/Battery Tester (refractometer) from Reichert offers a fast and easy-to-use method for testing engine coolant freeze
Battery Operated Carbon Monoxide Alarm Part Number 9CO5
Model KN-COB-B
Battery Operated (3AA’s included) Provides protection during power outage. Red Alarm LED Green Power LED Test/Reset Tests CO alarm circuit operation and allows you to immediately silence the alarm.
NEW FEATURE:
Snap Open Cover Gives access to batteries. Alertsimmediate user to replace CO alarm after 7 years
Alerts user to replace CO alarm NEW FEATURE: after 7 years of operation
Description
Features and Benefits
The Kidde 9CO5 battery operated carbon monoxide alarm utilizes sophisticated electronic components to protect you and your family from the dangers of carbon monoxide. This alarm includes a snap-on cover that gives immediate access to the batteries and a safety feature that makes it difficult to close the cover without the batteries being installed. This easy-to-install alarm is suitable for all living areas and has a 7-year life and a 5-year limited warranty.
• Battery Operated (3AA’s included) – Provides protection during power outage.
Consumer Benefits
• Low Battery Signal – Alerts user when the battery needs to be replaced.
The Kidde 9CO5 provides you and your family with a loud warning signal against the dangers of elevated carbon monoxide levels in your home. The battery operated CO alarm provides continuous monitoring of CO levels, even during power outages when AConly units are not providing protection.
• Green LED – Flashes every 30 seconds to indicate the unit is operating properly. The green LED will also flash before a CO reading is taken and when any button is pressed.
• Battery Lockout System – Deters covering battery compartment without installation of batteries. • Snap Open Cover – Gives immediate access to batteries. • Test/Reset Button – Tests the unit for proper operation – Resets the Carbon Monoxide Alarm
• Red LED – When a dangerous level of carbon monoxide is detected the red LED will pulse and a loud alarm pattern will sound. The carbon monoxide alarm pattern is 4 short beeps, followed by 5 seconds of silence, followed by 4 short beeps with a corresponding red LED flash. This cycle will continue for 4 minutes and then change to 1 cycle every minute until the device is reset or the CO is eliminated. SIGNALING
UL LISTED
Battery Operated Carbon Monoxide Alarm
Part Number 9CO5 Model KN-COB-B
Architectural and Engineering Specifications
Technical Specifications Part Number:
9CO5
The carbon monoxide alarm shall be Kidde Unit Number KN-COB-B (part number 9CO5) or approved equal. It shall be powered by three (3) AA batteries (included). The unit shall have a snap open cover that allows immediate access to batteries. The temperature operating range shall be between 40˚F and 100˚F (4˚C and 38˚C) and the humidity operating range shall be 5% - 95% relative humidity. The CO sensor shall be of a fuel cell design and shall meet the sensitivity requirements of Underwriters Laboratories UL2034 Single and Multiple Station Carbon Monoxide Alarms. The alarm can be installed on the surface of any wall or ceiling following the UL/NFPA/Manufacturer’s recommended placement guidelines. The alarm shall include a battery lockout system that deters closure of battery door without using three batteries. The alarm shall include a test button that will electronically simulate the presence of CO and cause the unit to go into alarm. This sequence tests the unit’s electronics to ensure proper operation. Per UL 2034 requirements, the CO sensor will not alarm to levels of CO below 30 ppm and will alarm in the following time range when exposed to the corresponding levels of CO.
Model:
KN-COB-B
Power Source:
3 AA Batteries
Sensor:
Electrochemical
Audio Alarm:
85dB at 10ft
70 ppm CO Concentration 150 ppm CO Concentration 400 ppm CO Concentration
Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C) Humidity Range:
5%-95% relative humidity (RH)
Size:
5.25” diameter x 1.0625” depth
Weight:
.5lb
Wiring:
None
Interconnects:
No
Warranty:
5 year limited 5.25"
1.0625"
60 – 240 minutes 10 – 50 minutes 4 – 15 minutes
The unit shall incorporate 2 LED’s. A green LED will flash once every 30 seconds to indicate the alarm is operating properly when power is present. A red LED will pulse to to indicate carbon monoxide has been detected until the device is reset or CO is eliminated. The alarm shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. When the unit detects carbon monoxide, the alarm pattern will be four (4) short beeps – followed by five (5) seconds of silence – followed by four (4) short beeps with a corresponding red LED flash. It shall also include a 5-year manufacturer’s limited warranty.
Ordering Information Clamshell UPC: 0-25417-69129-0 Bulk UPC: 0-47571-05292-9 Part Number