For and ,Please Con˜gure Online. Air Sheathed Heaters Air

2 -1519 2 -1520 Air Sheathed Heaters Standard / Configurable QStandard M Material : Element : 304 Stainless Steel Bushing : 304 Stainless Steel...

2 downloads 271 Views 2MB Size
For Pricing and Days to Ship,Please Configure Online.

Air Sheathed Heaters

Air Sheathed Plug Heaters / Small Hot Air Generators

Standard / Configurable EBe sure to refer to "Precautions for Use" in the Heaters for Air Heating Overview on P.1517

Ø32

Heater Element Ø12

Terminal M5

150

50

30 L

25 23

72

M20x3

L

25 23

0 -10

Part Number Type

M Material : Element : 304 Stainless Steel Bushing : 304 Stainless Steel A Accessories: Gasket : Non Asbestos (only for U and M Types) Flat Washer : 304 Stainless Steel 11 2Nut Nut : 304 Stainless Steel 1 Bushing for S Type: Insulator (only for S type) 2 pcs. 2 Nut for S Type: Insulator (only for S type) 2 pcs. Ø34.5

Ø12.5

Ø30 Ø32

40±5 25

L±10

10 15 25

1Bushing

EMaximum Operating Temperature: 160°C

MAHP

Part Number

Unit Price

MAHZA MAHZB MAHZC

(Ø21)

Ø13

Ø24

Ø28

3

Part Number 1mm Increment Type No. L A

L610~700

V W (Electric Power) (Voltage) 10W Increment

60~100 Unit Price L810~900

L710~800

2

200

440

Ø2.3

100 200

150~1750

L910~1000

Electrical Power Density (W/cm2)

Unit Price L200~300 L301~400 L401~500 L501~600

0.3≤W/cm2≤4.0 EW/cm2=W/3.77{(2L+0.57A-84)/10}

L1010~1100

L1110~1200

L1210~1300

L1310~1400

-

L

-

350

Part Number

-

L

MAHSS12

-

400

-

A

-

V

-

W

- A100 - V200 - W600 -

V

-

W

- V200 - W150

QMounting Method for MAHSS · S lit has been added to aluminum rings. Please expand rings by hand. · Use mounting plate with thickness 3mm or less.

Compressor, Tank etc.

Configure Online Configure Online

Stabilizing Power Supply

Dryer (Natural Convection Type) equipped with a rack on the top

Aluminum Ring

Voltage Regulator Volt Slider etc.

MAHUS

MAHMS

Ø13

4

3

2

Load Limit

1

Voltage Controller (Variac)

MAHZC Compressed Air Supply (Connected to air tubes, etc)

Configure Online

Flow Rate Controller (P.1304) Tube

Small Hot Air Generator Heating Object

Q Calculation of Hot Air Temperature Use the following formula to estimate hot air temperature. Hot Air Temperature [°C]≈

50x Power Consumption [W] Flow Rate of Compressed Air [l/min]

Power consumption should be made smaller than W (electric power) of each type. The above formula is for reference. If hot air temperature is high while flow rate is small, heat efficiency may decrease. Hot air temperature must be set lower than 800°C.

Heating Object Radiation-proof Heat Insulation Plate °C Thermometer

· Flow Rate / Supply Voltage / Hot Air Temperature Characteristics 900 800 700 600 500 400 300 200 100

Flow Rate l/min 10

100V-350W

30

60

20

40

V Voltmeter

QApplicable / Not Applicable Gases The list below is for reference only and not a product guarantee. Gas Applicable or Not Cautions / Others Air / Oxygen Avoid large amounts of oil mist or water. p All inert gases are applicable, but they will decrease the life span of the product. Nitrogen / Argon g Igniting occurs if the gas is exposed in the air at temperature 600°C or more. Hydrogen r Water Vapor r~n Letting the heat generator get wet will cause breakage. Town Gas / LPG After thermal decomposition, carbon adheres to the heat generator. n

Heater Element

Flanged Insulator

Flow Rate Controller

5

Connecting Socket PT1/8

Small Hot Air Generator

Flow Meter

Unit Price MAHZB

Configure Online

Pressure Regulator

L1410~1500

MAHZA

Quartz Glass

800°C

QUsage Procedure 1 Introduce compressed air before turning on small hot air generator. 2 Confirm the compressed air is flowing and apply a voltage to it. 3 Put the nozzle toward the object, and start heating. * Temperature Adjusters (P.1555) and Temperature Controllers (P.1560) cannot be used.

Compressed Air Source

Part Number

2(0.2)

Q Usage · Spot Drying after Workpiece Cleaning · Welding of Resin Products · Soldering of Electronic Parts such as IC chips · Cap Seal Shrinkage (Shrink Packaging) · Cutting (heat cutting) of Resin Film etc. · Shrinkage of Pipe Wrapping Tubes

12

MAHUS12

60

18

(0.5)

QFeature MISUMI's small hot air generators employ quartz glass which excels in heatresistance on the body and ceramic processed special elements on the heat generator. Compact, safe, and clean hot air can be obtained.

QU-shaped Configurable

L510~600

350

Temperature Monitoring Hole

4UBOE

22

Heater Element Ø12

12 200~600

100

MAHZA1

Ring Groove MAHSS M Material: Element: 321 Stainless Steel A Accessories: Flanged Insulator, Aluminum Ring (2 pcs. each)

MAHUS

1

Quartz Glass As heat generation increase, temperature monitoring holes will turn red in order of 5 to 1. The load reaches the limit when the 5th to 2nd lights turn red and the 1st light remains black. Keep the color of the 5th hole black during using. Blast Orifice

W Operating Part Number V Max. Flow Operating Gas Pressure Maximum Temperature (Electric kgf/cm2(MPa) Type No. (Voltage) Power) (l/min) Temperature

Part Number

30±5

EMaximum Operating Temperature: 160°C

2 -1519

Maximum Operating E Temperature: 800°C

7 8

L±10

18

60

80

100

Supply Voltage [V]

120

Hot Air Temperature [°C]

0

L -10

: 321 Stainless Steel :304 Stainless Steel(M16x1.5) : (2 pcs. each) : Non Asbestos : 304 Stainless Steel : 304 Stainless Steel (M16x1.5) Thickness : 6, Opposite : 24, Opposite Side : 27.7 Angle

M Material: Generator: Quartz Glass / Case: Stainless Steel

(2.5)

(Flat Tip)

(Ø24)

A(±2)

Ø24 Heater Element Ø12

5

30±5

L410~500

Ø5 14 5 11

102

(Point Tapered)

MAHUS M Material Element Bushing A Accessories Gasket Flat Washer Nut

30

Terminal M5

L310~400

R(PT)1/8

Case

(Standard)

MAHZB

MAHSS (S Type) (100V, 116V, 200V / Single-phase)

L200~300

2-M4Crimp Terminal

2-Lead Wire Length=(160)

MAHZC

22 20 5

MAHSS

MAHP

MAHZA

Configure Online

Terminal M5

Part Number L V W (Electric Power) Electrical Power Density (W/cm2) Type No. 10mm Increment (Voltage) 10W Increment 100 0.7≤W/cm2≤4.0 116 200~1500 150~2250 MAHSS 12 EW/cm2=W/3.77(L/10) 200

Air IN

Temperature Monitoring Hole

Welded in Argon Shield (Circumference)

QS-shaped Configurable

Partition Plate Air OUT

Unit Price

Configure Online

(Ø8.5)

2.0 3.0 4.0 4.5 3.9 4.1 4.2 4.3

Bushing M16

22

W V Electrical Power Density (Electric Power) (Voltage) (W/cm2) 1000 2000 3000 200 2.5 4000 5000

5.5

24

Part Number Type No.

Small Hot Air Q Generators

MAHUS (U Type) (100V, 200V / Single-phase)

QConfigurable

14

Configure Online

MAHP3

Configure Online

MAHU4

230 400 580 760 890

M Material: Element : 316L Stainless Steel Plug : CF-8M Stainless Steel Cast Cap : CF-8 Stainless Steel Cast A Accessories: Gasket: Non Asbestos

0 -10

(Ø2)

200 270 400 510 200 250 280 330 330 420 500 590

Electrical Power Density (W/cm2) 4.0

Heater Element Ø12

L

(26)

W V (Electric Power) (Voltage) 500 100 1000 200 1500 2000 500 100 1000 200 1500 2000 500 667 200 833 1000

L

L

No. 1 2 3 4 5

Part Number

QU / M / S Type Heaters Part Number Type No. 1 2 MAHU 3 4 1 2 MAHM 3 4 1 2 MAHS 3 4

75

EMaximum Operating Temperature: 160°C

30

Plug G(PF)2

20

Cap

Bushing M16

Heater Element Ø12

25 40±5

3

(Air Sheathed, 200V / Three-phase)

0 -10

MAHS (S Type) (200V / Single-phase) Terminal M5

MAHP

Hot Air Temperature [°C]

Terminal M5

Heater Element Ø12

83

Bushing M16

Air Sheathed Plug Q Heaters

MAHM (M Type) (100V, 200V / Single-phase)

Ø62

MAHU (U Type) (100V, 200V / Single-phase)

Ø32

QStandard

14

EBe sure to refer to "Precautions for Use" in the Heaters for Air Heating Overview on P.1517

900 800 700 600 500 400 300 200 100

Flow Rate l/min 10

200V-440W

30 60

40

80

120

160

200

240

Supply Voltage [V]

[IMPORTANT] Cautions ECheck the air flow supply before applying a voltage. Never use without air flow. After turning off the small hot air generator, please keep the compressed airflow for 3 min or more. Then stop E air flow supply when the temperature of the hot air is lower than 50°C. EQuartz glass is used on the body. Do not apply an impact. EThe body and case get very hot during the operation. Do not touch them.It will cause burn injury. EVoltage and electric power should be set lower than the rated values. EDo not exceed max. operating temperature (800°C).

2 -1520