CPW Municipal Water Booster Pump Station DESIGN ASSISTANCE

Carolina Pumpworks Municipal Water Booster ... An approximate footprint size of the pump ... A completed Carolina Pumpworks TDH calculator...

4 downloads 584 Views 186KB Size
Submit by Email

Print Form

Carolina Pumpworks Municipal Water Booster Pumping Station  Design Assistance Form    Project Name:       Project Location:   Engineering Firm:     1. What stage of design process is this project in now?      Unknown       Feasibility      Preliminary      Detailed      Final      2. What information is needed now?    NOTE: Check only what is appropriate to the stage of design above.    A budget price.  An approximate footprint size of the pump system.  Number of pumps and motor sizes only.  An example drawing of a similar pump system.  An example specification of a similar pump system.  A detailed specification specific to this project.  A detailed drawing specific to this project.      3. If detailed specs and plans are required, provide the following:      A completed Carolina Pumpworks TDH calculator spreadsheet.  The project engineers’ contact information:    Name:     Phone Number:    E‐Mail Address:      4. What are the basic design conditions?      See the Carolina Pumpworks TDH calculator spreadsheet.    See below:          GPM (without any redundancy included)  Design flow rate =     Design discharge pressure =       PSIG (exiting the pump system)  Minimum suction pressure =      PSIG (at the design flow rate)  Maximum suction pressure =      PSIG (highest static at the inlet)  -1-

5. What type of pump system is required?    A grid booster system – pumps domestic and fire flow into a water system.  A tank fill system – fills a remote water storage tank or reservoir.  A plant water system – in a water treatment plant.  A seal water system – in a water treatment plant.  An irrigation system – pumps to a turf sprinkler system.  An effluent distribution system – pumps to a reuse water system.  Other or unknown – provide a description and/or a diagram.      6. What is the source of supply water?    A pressurized water main.  A flooded suction pipe.  An adjacent storage tank.    A wet pit, below grade tank, or pond (water level below the pumps)      7. What will the power supply be?    3 – Phase, 60 Hertz,             Volts.  Single Phase, 60 Hertz,     Volts.  Other:       8. What other major components are required? Check all that apply:    A prefabricated pump house  A generator and transfer switch  A back flow preventer  A bypass check valve  A turbine water meter  A magnetic flow meter  Other:  Other:          listed elsewhere.      9. Are there any special brands or models of equipment required?    No      See below:    Pump mfg / model: PLC brand / model:  Other products: 

-2-