HHD-BM FUSES
Selection Guide HHD-BM & HHD-BMR, DIN Style Current-Limiting, Back-Up, Motor Protection Current ratings [A]; 50, 63, 80, 100, 125, 160, 200, 250, 315, 355, 400, 450 E=192mm
Page
E=292mm
Page
3020153.50 - 100 3020253.125 - 160 3020054.200 - 315 3020554.355 - 450
64 64 64 64
E=367mm 3 / 3.6kV
Page
E=442mm
Page
3010853.50 - 100 3010953.125 - 160 3011054.200 - 315 3011154.355 - 450
66 66 66 66
3010153.50 - 63 3010253.80 - 125 3010353.160 3010354.200
68 68 68 68
E=537mm
Page
3/ 7.2kV
6 / 12kV
HHD-BMR, DIN Style Current-Limiting, Back-Up, R - Rated Current ratings [A]; 2R(70A), 3R(100A), 4R(130A), 5R(150A), 6R(170A), 9R(200A), 12R(230A), 18R(390A), 24R(450A), 36R(650A), 48R[700A] 2.4 /7.3kV 3010855.2R - 3R 3010955.4R - 6R 3011055.9R - 48R
Phone 1-973-575-7422 Fax 1-973-575-5858
SIBA LLC 29 Fairfield Place West Caldwell, New Jersey 07006
70 70 70
e-mail:
[email protected] www.siba-fuses.us
63
HHD-BM FUSES HHD-BM
High Voltage Current-Limiting Fuses
3/3.6kV - Rated Voltage
[A]
Article Number
DIN 43 625 IEC 60282-1 IEC 606644 VDE 0670 - 4
Class Back-Up
Size E=292mm Rated Current In
Standard(s)
Motor Applications
Diameter D
Weight
[in/mm]
[kg/1]
Rated Breaking Current I1
Minimum Breaking Current I3
Pre-arcing
[kA]
[A]
[A s]
Total
Power Loss
Cold Resistance
[A s]
2
[W]
[m]
ņ ņ ņ ņ ņ ņ
11 000 17 000 20 000 44 000 78 000 199 000
27 38 44 47 51 53
13 10 8.5 5.6 4.3 2.7
ņ ņ ņ ņ
376 000 448 000 952 000 1 500 000
58 61 64 75
1.9 1.7 1.2 0.84
ņ ņ ņ
2 360 000 3 290 000 3 800 000
82 87 92
0.75 0.69 0.59
2
2
I t 2
I t@ 0.87Un(Max) 2
[A s]
Single Barrel - With 80N Striker and Thermal Sensor 50 63 80 100 125 160
3020153.50 3020153.63 3020153.80 3020153.100 3020253.125 3020253.160
2.09 / 53 2.09 / 53 2.09 / 53 2.09 / 53 2.64 / 67 2.64 / 67
1.7 1.7 1.7 1.7 2.6 2.6
200 224 250 315
3020054.200 3020054.224 3020054.250 3020054.315
3.35 / 85 3.35 / 85 3.35 / 85 3.35 / 85
3.9 3.9 3.9 3.9
355 400 450
3020554.355 3020554.400 3020554.450
3.35 / 85 3.35 / 85 3.35 / 85
8.4 8.4 8.4
50 50 50 50 50 50
140 165 200 285 375 490
3 400 5 400 6 110 14 000 25 000 64 000
Single Barrel - With 120N 50 50 50 50
690 790 1 050 1 260
121 000 144 000 307 000 615 000
Double Barrel - With 120N Striker 50 50 50
2 130 2 400 2 700
760 000 1 060 000 1 230 000
Accessories Article Description Fuse Base, Indoor Fuse Base, Outdoor Clips Clips w/Connecting Bar Microswitch fittings
ч 200A 3100302 3100401 3100302.20 3400201 250mm - 3100116,
>200A 3100306 3100406 3400101.20 3400102 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117
Dimensions [mm]
64
Phone 1-973-575-7422 Fax 1-973-575-5858
SIBA LLC 29 Fairfield Place West Caldwell, New Jersey 07006
e-mail:
[email protected] www.siba-fuses.us
Page(s) 98 99 100 100 97
HHD-BM FUSES
HHD-BM
Time-Current Characteristics - Minimum Melting and Total Clearing Cut-Off Current Diagram Current-Limiting, Back-Up, 3/3.6kV, E = 292mm (50A - 450A) 3020153.50 - 100, 3020253.125 - 160, 3020054.200 - 315, 3020354.355 - 450
Minimum Melting
Total Clearing 10 4
10 4
H20153-302_0
H20153-301_0
10 3
s
10 2
8 10 3
2
3
4
5 6
8 10 4
A
2
3
4
5 6
10 1
8 10 5
A 450 A 400 A 355 A 315
5 6
A 250
4
A
10 -2
3
A 224 A 200
2
10 -2
2
A
3
2
8 10 2
A
3
2
3
4
5 6
8 10 2
2
3
8 10 3
2
3
4
5 6
8 10 4
A
2
3
4
5 6
8 10 5
R.M.S. Prospective Current [A] Cut-Off Current
10 3 H20153-40_1
kA
Cut-Off Current - Peak [kA]
5 6
125
8
4
160
10 -1 6 5 4
3
5 6
10 0
8
2
4
10 1
6 5 4
10 1
100
10 -1
50 A
10 0
10 2 80 A
A
A 450 A 400 A 355 A 315
160
A
A
A 250
125
A 224 A 200
100
50 A
80 A
63 A
10 1
s
63 A
Virtual Pre-arcing time - [s]
10 3
10 2
450 A 400 A 355 A 315 A 250 A 200 A 224 A 160 A 125 A
10 1
100 A
80 A 63 A 50 A
10 0 8 6
4 3
2
10 -1
2
3
4
6
8
10 0
10 1
10 2
kA
10 3
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Phone 1-973-575-7422 Fax 1-973-575-5858
SIBA LLC 29 Fairfield Place West Caldwell, New Jersey 07006
e-mail:
[email protected] www.siba-fuses.us
65
HHD-BM FUSES HHD-BM
High Voltage Current-Limiting Fuses
Article Number
DIN 43 625 IEC 60282-1 IEC 606644 VDE 0670 - 4
Class Back-Up
Size E=442mm Rated Current In [A]
Standard(s)
Motor Applications
3/7.2kV - Rated Voltage
Diameter D
Weight
[in/mm]
[kg/1]
Rated Breaking Current I1 [kA]
Minimum Breaking Current I3 [A]
Pre-arcing
Total
Power Loss
Cold Resistance
[A s]
[W]
[m]
ņ ņ ņ ņ ņ ņ
16 000 25 000 29 000 65 000 115 000 295 000
23 49 72 74 81 91
ņ ņ ņ ņ
559 000 694 000 1 480 000 3 000 000
89 103 98 120
1.9 1.7 1.2 0.84
ņ ņ ņ
3 700 000 4 400 000 5 950 000
131 150 163
0.75 0.69 0.59
I2 t [A2s]
2
I t@ 0.87Un(Max) 2
2
[A s]
Single Barrel - With 80N Striker and Thermal Sensor 50 63 80 100 125 160
3010853.50 3010853.63 3010853.80 3010853.100 3010953.125 3010953.160
2.09 / 53 2.09 / 53 2.09 / 53 2.09 / 53 2.64 / 67 2.64 / 67
2.5 2.5 2.5 2.5 3.7 3.7
200 224 250 315
3011054.200 3011054.224 3011054.250 3011054.315
3.35 / 85 3.35 / 85 3.35 / 85 3.35 / 85
5.7 5.7 5.7 5.7
355 400 450
3011154.355 3011154.400 3011154.450
3.35 / 85 3.35 / 85 3.35 / 85
11.4 11.4
50 50 50 50 50 50
140 165 200 280 375 490
3 400 5 400 6 110 14 000 25 000 64 000
13 10 8.5 5.6 4.3 2.7
Single Barrel - With 120N 50 50 50 50
690 790 1 050 1 260
121 000 144 000 307 000 627 000
Double Barrel - With 120N Striker
11.4
50 50 50
2 130 2 400 2 700
759 000 903 000 1 230 000
Accessories Article Description Fuse Base, Indoor Fuse Base, Outdoor Clips Clips w/Connecting Bar Microswitch fittings
ч 200A 3110102 ņ 3100302.20 3400201 250mm - 3100116,
>200A 3110106 ņ 3400101.20 3400102 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117
Dimensions [mm]
66
Phone 1-973-575-7422 Fax 1-973-575-5858
SIBA LLC 29 Fairfield Place West Caldwell, New Jersey 07006
e-mail:
[email protected] www.siba-fuses.us
Page(s) 98 99 100 100 97
HHD-BM FUSES HHD-BM
Time-Current Characteristics - Minimum Melting and Total Clearing Cut-Off Current Diagram Current-Limiting, Back-Up, 3/7.2kV, E = 442mm (50A - 450A) 3010853.50 - 100, 3010953.125 - 160, 305 4.200 - 315, 3011154.355 - 450
Minimum Melting
Total Clearing
10 4
10 4 H10853-301_0
H10853-302_0
10 3
s
10 2
A 450 A 400 A 355 A 315
A
A 250
A
A
5 6
A 224 A 200
125
4
10 1
10 0
10 -1 8
6 5 4
6 5 4
3
3
2
2
10 -2
10 -2
2
3
4
5 6
8 10 2
2
3
4
5 6
8 10 3
2
3
4
5 6
8 10 4
A
2
3
4
5 6
10 1
8 10 5
2
3
4
5 6
8 10 2
2
3
8 10 3
2
3
4
5 6
8 10 4
A
2
3
4
5 6
8 10 5
R.M.S. Prospective Current [A] Cut-Off Current
10 H10853-40_2
kA
Cut-Off Current - Peak [kA]
10 1
160
8
100
10 -1
50 A
10 0
10 2 80 A
A 450 A 400 A 355 A 315
A
A 250
160
A
A
A 224 A 200
125
80 A
100
50 A
63 A
10 1
s
63 A
Virtual Pre-arcing time - [s]
10 3
10 2
450 A A 355 A 400 315 A 250 A 200 A 224 A 160 A
125 A
10 1
80 A 50 A
100 A 63 A
10 0 8 6
4 3
2
10 -1
2
3
4
6
8
10 0
10 1
10 2
kA
10 3
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Phone 1-973-575-7422 Fax 1-973-575-5858
SIBA LLC 29 Fairfield Place West Caldwell, New Jersey 07006
e-mail:
[email protected] www.siba-fuses.us
67
HHD-BM FUSES HHD-BM
High Voltage Current-Limiting Fuses
6/12kV - Rated Voltage
[A]
Article Number
DIN 43 625 IEC 60282-1 IEC 606644 VDE 0670 - 4
Class Back-Up
Size E=442mm Rated Current In
Standard(s)
Motor Applications
Diameter D
Weight
[in/mm]
[kg/1]
Rated Breaking Current I1
Minimum Breaking Current I3
Pre-arcing
[kA]
[A]
[A s]
Total
I2 t 2
Power Loss
Cold Resistance
[A s]
[W]
[m]
2
I t@ 0.87Un(Max) 2
[A s]
2
Single Barrel - With 80N Striker and Thermal Sensor 50 63 80 100 125
3010153.50 3010153.63 3010253.80 3010253.100 3010253.125
2.09 / 53 2.09 / 53 2.64 / 67 2.64 / 67 2.64 / 67
2.6 2.6 3.7 3.7 3.7
50 50 50 50 50
140 165 200 280 375
3 400 5 400 6 200 14 000 25 000
ņ ņ ņ ņ ņ
16 000 25 000 29 000 65 000 115 000
60 69 73 95 131
18 15 13 8.5 6.3
160
3010353.160
3.35 / 85
5.7
50
490
64 000
ņ
295 000
149
4
121 000
ņ
559 000
174
3
With 120N Striker 200
3010354.200
3.35 / 85
5.7
50
690
Accessories Article Description Fuse Base, Indoor Fuse Base, Outdoor Clips Clips w/Connecting Bar Microswitch fittings
ч 200A 3110102 ņ 3100302.20 3400201 250mm - 3100116,
>200A 3110106 ņ 3400101.20 3400102 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117
Dimensions [mm]
68
Phone 1-973-575-7422 Fax 1-973-575-5858
SIBA LLC 29 Fairfield Place West Caldwell, New Jersey 07006
e-mail:
[email protected] www.siba-fuses.us
Page(s) 98 99 100 100 97
HHD-BM FUSES
HHD-BM
Time-Current Characteristics - Minimum Melting and Total Clearing Cut-Off Current Diagram Current-Limiting, Back-Up, 6/12kV, E = 442mm (50A - 200A) 3010153.50 - 63, 3010253.80 - 125, 3010353.160, 3010354.200
Minimum Melting
Total Clearing 10 4
10 4
H10153-302_0
H10153-301_0
10 3
s
10 2
5 6
8 10 3
2
3
4
5 6
8 10 4
A
2
3
4
5 6
10 1
8 10 5
A
4
A
10 -2
3
200
2
10 -2
2
A
3
2
8 10 2
A
3
2
3
4
5 6
8 10 2
2
3
8 10 3
2
3
4
5 6
8 10 4
A
2
3
4
5 6
8 10 5
R.M.S. Prospective Current [A] Cut-Off Current
10 3 H10153-40_1
kA
Cut-Off Current - Peak [kA]
5 6
125
8
4
160
10 -1 6 5 4
3
5 6
10 0
8
2
4
10 1
6 5 4
10 1
100
10 -1
50 A
A
A
10 0
10 2 80 A
200
A
A
160
125
80 A
100
50 A
63 A
10 1
s
63 A
Virtual Pre-arcing time - [s]
10 3
10 2
200 A 125 A
10
1
160 A 100 A
80 A 63 A 50 A
10 0 8 6
4 3
2
10 -1
2
3
4
6
8
10 0
10 1
10 2
kA
10 3
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Phone 1-973-575-7422 Fax 1-973-575-5858
SIBA LLC 29 Fairfield Place West Caldwell, New Jersey 07006
e-mail:
[email protected] www.siba-fuses.us
69
HHD-BMR FUSES HHD-BMR
High Voltage Current-Limiting Fuses
2.4/7.2kV - Rated Voltage
Motor Applications
[A]
Article Number
DIN 43 625 IEC 60282-1 IEC 606644 VDE 0670 - 4
Class Back-Up
Size E=442mm Rated Current In
Standard(s)
Diameter D
Weight
[in/mm]
[kg/1]
Rated Breaking Current I1
Minimum Breaking Current I3
Pre-arcing
[kA]
[A]
[A s]
Total
Power Loss
Cold Resistance
[A s]
[W]
[m]
ņ ņ ņ ņ ņ
24 400 41 400 91 500 169 400 280 100
63 106 112 119 125
10 7 5 3.7 2.8
ņ ņ
462 000 764 000
123 118
2.1 1.6
ņ ņ
1 850 000 3 053 000
246 236
1.1 0.8
ņ ņ
6 869 000 12 447 000
354 476
0.55 0.45
I2 t 2
2
I t@ 0.87Un(Max) 2
[A s]
2
Single Barrel - With 80N Striker 70 100 130 150 170
3010855.2R 3010855.3R 3010955.4R 3010955.5R 3010955.6R
2.09 / 53 2.09 / 53 2.64 / 67 2.64 / 67 2.64 / 67
2.5 2.5 3.7 3.7 3.7
200 230
3011055.9R 3011055.12R
3.35 / 85 3.35 / 85
5.7 5.7
390 450
3011055.18R 3011055.24R
3.35 / 85 3.35 / 85
11.4 11.4
650 700
3011055.36R 3011055.48R* * 2.4kV - 4.8kV
3.35 / 85 3.35 / 85
17.1 17.1
50 50 50 50 50
160 220 320 400 480
5 400 9 000 20 400 37 600 62 200
Single Barrel - With 120N Striker 50 50
690 900
100 400 170 000
Double Barrel - With 120N Striker 50 50
1 400 1 800
402 000 678 000
Triple Barrel - With 120N Striker 50 50
2 600 3 000
1 527 000 2 766 000
Accessories Article Description Fuse Base, Indoor Fuse Base, Outdoor Clips Clips w/Connecting Bar Microswitch fittings
ч 200A 3110102 ņ 3100302.20 3400201 250mm - 3100116,
>200A 3110106 Single Barrel Application Only ņ 3400101.20 3400102 660mm - 3100110, 900mm - 3100114, 1200mm - 3100117
Dimensions [mm]
70
Phone 1-973-575-7422 Fax 1-973-575-5858
SIBA LLC 29 Fairfield Place West Caldwell, New Jersey 07006
e-mail:
[email protected] www.siba-fuses.us
Page(s) 98 99 100 100 97
HHD-BMR FUSES
HHD-BMR
Time-Current Characteristics - Minimum Melting and Total Clearing Cut-Off Current Diagram Current-Limiting, Back-Up, 2.4/7.2kV, E = 442mm (2R - 48R) 3010855.2R - 3R, 3010955.4R - 6R, 3011055.9R - 48R
Minimum Melting
Total Clearing
04
10 4 H10855-301_0
H10855-302_0
03
s
02
48
R
R
24 R
36
5 6
18 R
4
9R
3
R 12
2
10 1
10 0
10 -1 8
8
6 5 4
6 5 4
3
3
2
2
10 -2
0 -2
2
3
4
5 6
8 10 2
2
3
4
5 6
8 10 3
2
3
4
8 10 4
5 6
A
2
3
4
5 6
10 1
8 10 5
2
3
4
5 6
8 10 2
8 10 3
2
3
4
5 6
8 10 4
A
2
3
4
5 6
8 10 5
R.M.S. Prospective Current [A] Cut-Off Current
10 3 H10855-40_1
kA
Cut-Off Current - Peak [kA]
10 1
6R 5R
0 -1
3R
R
R
00
10 2
4R
48
24 R
36
18 R
9R
R 12
6R 5R
3R
4R
2R
01
s
2R
Virtual Pre-arcing time - [s]
10 3
10 2 48 R 24 R 12 A 6R
10
4R
1
2R
36 R 18 R 9R 5R 3R
10 0 8 6
4 3
2
10 -1
2
3
4
6
8
10 0
10 1
10 2
kA
10 3
Prospective Short Circuit Current [kA] - (Symmetrical r.m.s.)
Phone 1-973-575-7422 Fax 1-973-575-5858
SIBA LLC 29 Fairfield Place West Caldwell, New Jersey 07006
e-mail:
[email protected] www.siba-fuses.us
71