NZS 1170.2:2002 Structural Design Actions - Wind

AS/NZS 1170.2:2002 Structural Design Actions - Wind Actions View on Information Provider website {{ linkText }} Abbreviation ... PDF Cited By This res...

6 downloads 730 Views 60KB Size
Menu Home About this portal Latest updates

Print Save Email Resource detail Citations

AS/NZS 1170.2:2002 Structural Design Actions - Wind Actions View on Information Provider website {{ linkText }} Abbreviation AS/NZS 1170.2:2002 Amendment AS/NZS 1170.2:2002 A1 . - incorporated. Published 03/04/2005. Valid from 03/06/2002 Information provider Standards New Zealand Author Standards New Zealand, Standards Australia Information type New Zealand Standard Format PDF Cited By This resource is cited by 16 documents (show Citations) Cites This resource cites 1 document (show Citations)

Description

This Standard is Part 2 of the AS/NZS 1170 series Structural design actions. The objective of this Standard is to provide designers of structures with wind actions for use in the design of structures subject to wind action. It provides a detailed procedure for the determination of wind actions on structures, varying from those less sensitive to wind action to those for which

dynamic response must be taken into consideration. Wind speeds and direction factors are provided for a range of probabilities of exceedance. Other factors cover the environment around the structure, the geometry of the structure and the dynamic interaction of the structure with the wind. It is intended to be used in conjunction with AS/NZS 1170.0, which gives the procedure for structural design. The Commentary to this Standard is AS/NZS 1170.2 Supp 1, Structural design actions— Wind actions—Commentary (Supplement to AS/NZS 1170.2:2002).

Scope

This Standard sets out procedures for determining wind speeds and resulting wind actions to be used in the structural design of structures subjected to wind actions other than those caused by tornadoes. The Standard covers structures within the following criteria: (a) Buildings less than 200 m high; (b) Structures with roof spans less than 100 m; and (c) Structures other than offshore structures, bridges and transmission towers. Notes: 1. This Standard is a stand-alone document for structures within the above criteria. It may be used, in general, for all structures but other information may be necessary. Guidance on wind tunnel testing, reliable references and alternative data is given in AS/NZS 1170.2 Supp 1, Structural design actions—Wind actions—Commentary (Supplement to AS/NZS 1170.2:2002). 2. Where structures have natural frequencies less than 1 Hz, Section 6 requires dynamic analysis to be carried out. For assistance with locating previous versions, please contact the information provider.

View on Information Provider website {{ linkText }} For assistance with locating previous versions, please contact the information provider.

This resource is cited by:

AS/NZS 1170.2:2002 Structural Design Actions - Wind Actions This document is CITED BY:

AS 2050-2002

AS/NZS 1170.2:2002 is cited by AS 2050-2002 Installation of roof tiles AS/NZS 1170.0:2002 AS/NZS 1170.2:2002 is cited by AS/NZS 1170.0:2002 Structural Design Actions - General principles AS/NZS 1170.1:2002 AS/NZS 1170.2:2002 is cited by AS/NZS 1170.1:2002 Structural Design Actions - Permanent, imposed and other actions AS/NZS 1170.3:2003 AS/NZS 1170.2:2002 is cited by AS/NZS 1170.3:2003 Structural Design Actions - Snow and ice actions AS/NZS 4284:2008 AS/NZS 1170.2:2002 is cited by AS/NZS 4284:2008 Testing of building facades CP01:2014 AS/NZS 1170.2:2002 is cited by Code of Practice for Weathertight Concrete and Concrete Masonry Construction NASH Part 1 2010 Design criteria AS/NZS 1170.2:2002 is cited by NASH Standard - Residential and Low-Rise Steel Framing Part 1 2010 Design Criteria NZS 3101.1&2:2006 AS/NZS 1170.2:2002 is cited by NZS 3101.1&2:2006 Concrete structures standard The design of concrete structures NZS 3404 Parts 1 and 2:1997 AS/NZS 1170.2:2002 is cited by NZS 3404 Parts 1 and 2:1997 Steel structures standard NZS 3604:2011 AS/NZS 1170.2:2002 is cited by NZS 3604:2011 Timber-framed buildings NZS 4211:2008 AS/NZS 1170.2:2002 is cited by NZS 4211:2008 Specification for performance of windows NZS 4223.1:2008 AS/NZS 1170.2:2002 is cited by NZS 4223.1:2008 Code of practice for glazing in buildings Glass selection and glazing

NZS 4223.4:2008 AS/NZS 1170.2:2002 is cited by NZS 4223.4:2008 Code of practice for glazing in buildings Wind, dead, snow, and live actions NZS 4230:2004 AS/NZS 1170.2:2002 is cited by NZS 4230:2004 Design of reinforced concrete masonry structures NZS 4251.1:2007 AS/NZS 1170.2:2002 is cited by NZS 4251.1:2007 Solid plastering - Cement plaster for walls, ceilings and soffits NZS 4541:2007 AS/NZS 1170.2:2002 is cited by NZS 4541:2007 Automatic fire sprinkler systems Back

AS/NZS 1170.2:2002 Structural Design Actions - Wind Actions Show what documents this resource is CITED BY Show what documents this resource CITES Description

This Standard is Part 2 of the AS/NZS 1170 series Structural design actions. The objective of this Standard is to provide designers of structures with wind actions for use in the design of structures subject to wind action. It provides a detailed procedure for the determination of wind actions on structures, varying from those less sensitive to wind action to those for which dynamic response must be taken into consideration. Wind speeds and direction factors are provided for a range of probabilities of exceedance. Other factors cover the environment around the structure, the geometry of the structure and the dynamic interaction of the structure with the wind. It is intended to be used in conjunction with AS/NZS 1170.0, which gives the procedure for structural design. The Commentary to this Standard is AS/NZS 1170.2 Supp 1, Structural design actions— Wind actions—Commentary (Supplement to AS/NZS 1170.2:2002).

View on Information Provider website AS/NZS 1170.2:2002 Structural Design Actions - Wind Actions Description

This Standard is Part 2 of the AS/NZS 1170 series Structural design actions. The objective of this Standard is to provide designers of structures with wind actions for use in the design of structures subject to wind action. It provides a detailed procedure for the determination of wind actions on structures, varying from those less sensitive to wind action to those for which dynamic response must be taken into consideration. Wind speeds and direction factors are provided for a range of probabilities of exceedance. Other factors cover the environment around the structure, the geometry of the structure and the dynamic interaction of the structure with the wind. It is intended to be used in conjunction with AS/NZS 1170.0, which gives the procedure for structural design. The Commentary to this Standard is AS/NZS 1170.2 Supp 1, Structural design actions— Wind actions—Commentary (Supplement to AS/NZS 1170.2:2002).

View on Information Provider website This resource cites:

AS/NZS 1170.2:2002 Structural Design Actions - Wind Actions This document CITES: New Zealand Standards

AS/NZS 1170.2 Supplement 1:2002 AS/NZS 1170.2:2002 cites AS/NZS 1170.2 Supplement 1:2002 Structural design actions Part 2: Wind actions - Commentary (Supplement to AS/NZS 1170.2:2002) Back Close Table of Contents

Print Save Email

Feedback

Contact us Privacy policy Disclaimer Copyright