The Commonwealth of Massachusetts Department of Fire Services 527 CMR 1.00 Section 1.12.8.2.1 Form 1 FP Application for Permit, Permit, and Certificat...
Lieutenant Governor September 12, 2017 To: Massachusetts Nursing and Professional Healthcare Organizations From: Laurie Talarico, MS, RN, CNP Nursing Practice
Application for Initial Licensure for Food Processing and/or Distribution at Wholesale In Accordance with M.G.L. C.94, § 305C and/or 105 CMR 500.000
The Commonwealth of Massachusetts . Executive Office of Health and Human Services . Department of Public Health . 250 Washington Street, Boston, MA 02108-4619
The Commonwealth of Massachusetts Executive Office of Labor and Workforce Development Department of Unemployment Assistance www.mass.gov/dua Form P2594 Rev. 10-02-17
Commonwealth of Massachusetts Executive Office of Health and Human Services Office of Medicaid www.mass.gov/masshealth MassHealth Transmittal Letter ALL-205
Commonwealth of Massachusetts Executive Office of Health and Human Services Office of Medicaid www.mass.gov/masshealth MassHealth . Transmittal Letter AOH-40
3 Massachusetts Department of Correction Mission Statement The Massachusetts Department of Correction's mission is to promote public safety by managing offenders
Department of Defense . Fire and Emergency Services Certification Program Procedural Guide. January 2017 . Air Force Civil Engineer Center . Fire Emergency Services
e commonwealth of massachusetts office of the attorney general western massachusetts division 1350 main street springfield, massachusetts 01103-1629
Salary Administration Rules for Managers, Confidential and Unclassified Employees September 2016 (Formerly the "Gray Book" Rules & Regulations Governing the
Commonwealth of Massachusetts MassHealth Provider Manual Series Subchapter Number and Title Appendix C. Third-Party-Liability Codes Page C-1 All Provider Manuals
probability is the CDF of R evaluated at −5. Since R is normally distributed, we can ... (20 100+380 50) = 52.5. ... Massachusetts Institute of Technology
department of state commonwealth of pennsylvania tom wolf governor pedroa. cortés secretary of the commonwealth
portion of these released tests for non-commercial educational purposes without requesting permission. All others should .... statement best explains the difference in the mouse populations on Island A and Island B at the end of the 20 .... This food
Title: Examination for Certificate of Fitness for Construction Site Fire Safety Manager (CSFSM) (S- 56)
This session contains fourteen multiple-choice questions, four short-answer questions, and
FY ’2012 UFR Audit & Preparation Manual 1 UFR AUDIT & PREPARATION MANUAL UNDER 808 CMR 1.00 Commonwealth of Massachusetts Executive Office for Administration & Finance
DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service ... NobelClinician ®, DTX Studio ... general controls provisions of the Act include requirements for
California Department of Social Services (CDSS) Foster Care Rates Bureau (FCRB) Overview of the Group Home Rate Classification Levels (RCLs) (Does not include
Rev. 11/13/2017 State of Connecticut, Department of Developmental Services Application Checklist Application packets received with Name
revised 12-2-14 fire department city of new york study material for the certificate of fitness examination f-02 fire guard for shelters (citywide)
revised 12/03/2015 . fire department city of new york. study material for the. consolidated examination f-60 for. fire guard for torch operations
revised 12/2/2014 fire department city of new york study material for the certificate of fitness examination for f-03 indoor place of assembly safety personnel
revised 11-15-13 3 4.1 pre- fire plan for construction site ..... 65 4.2 cda checklist
The Commonwealth of Massachusetts
Department of Fire Services 527 CMR 1.00 Section 1.12.8.2.1 Form 1
FP-056 (Rev. 1.26.2015)
Application for Permit, Permit, and Certificate of Completion for the Installation or Alteration of Fuel Oil Burning Equipment and the Storage of Fuel Oil
_______________________________________ (City or Town)
Net Stack Temp.: __________________________ Breech Draft:
________________________
Efficiency Rating %:
___________________
I, the undersigned certify that the installation of fuel burning equipment has been made in accordance with M.G.L. Chapter 148 and 527 CMR 1.00 currently in effect. Furthermore, this installation has been tested in accordance with such requirements, is now in proper operating condition and complete instructions as to its use and maintenance have been furnished to the person or whom the installation (or alteration) was made.
Installer: ____________________________________________________________________________________________________ Print Name
Cert of C#
Signature (no Stamp)
Address: _________________________________________________________________ City: ____________________________________________ Once signed by the fire department, this is a PERMIT for the storage of fuel oil and use of the oil burning equipment. Approved by: ___________________________________________________________________
Date: __________________________________
Keep original as application. Issue duplicate as permit. This form may be photocopied.
All applications must be on Form 1 Over 10,000 gallons on site requires License & Permit from local community Certificate of Competency required, no other license acceptable, plumbing, electrical, etc. Verify emergency shut-off is outside burner room Verify separate circuit for oil burner Verify presence of overhead thermal switch Verify presence of service switch within 3' of burner Verify presence of high limit controller Primary control has safety shutoff within 15 secs. Stack type primary may be easily removed Steam boiler equipped with low-water cut-off Clear access to clean out and services panels No oil leaks present at burner Installation instructions present on site Combustion test results on Form 1 Three metal screws at each joint in chimney Thimble present at chimney connection IF POWER VENTER IS USED: Check air pressure switch, post purge control and secondary control. Installation instructions present. Draft regulator is present unless exempted Adequate air is present for combustion Adequate clearances per manufacturers listing Thermal valves at burner and tanks Listed flexible hose may be used. No Teflon tape on oil line or on oil line fittings No compression fittings are permitted Solder joints made with 500 degree F solder or greater All oil supply and return lines must be protected from injury. All new lines must be continuously sleeved with non metallic tubing. Oil safety valves may be used on existing lines not exposed to freezing. Overhead lines require no sleeve and are permitted Oil supply lines and return lines to tanks exposed to freezing temperatures must come off the top of tanks Lines for kerosene, and range oil (#1) are exempt No oil leaks present at tank Listed oil filter is present Tank is UL80 or (DIB+) PV-VI 321 (under 660 gal) or UL 142 (over 600 gal) Shutoff valve located at bottom of tank Size of vent as per manufacturer Oil tank gauge must be present to determine oil level Inside tanks have audible fill device (vent alarm) Outlet cross connection at bottom of tanks must be 3/8" pipe or tubing. Non-combustible tank supports, tank secure.
Note To Installer: Inspections will be conducted using this checklist as a guideline. Current regulations will apply. UNENCLOSED TANKS
Single tanks shall not be larger than 660 gallons Maximum aggregate capacity of unenclosed multiple tanks is 1320 gallons Unenclosed tanks shall be at least five feet from an internal or external flame Unenclosed tanks shall not obstruct service meters, service panels and shutoff valves Bottom outlet tanks pitched to the opening Tanks exposed to vehicles will be protected by barriers ENCLOSED TANKS
Over 660 gallon tanks enclosed by two hour fire resistive assembly Tank enclosures provided with 6" high tight sills or ramps Tank is 4" above floor supported by 12" thick masonry saddles spaced not more than eight feet on centers and 15" from top and walls of enclosure All oil must be transferred by pump, and connections must be at the top of the tank ALL TANKS
Two tanks may be cross-connected as shown in Fig. 8.9.1 NFPA 31 2011 edition Return lines must enter the top of tanks Vent pipes must be two feet from building openings Vent pipes must terminate 3 ft. above grade min. Vent pipes must have weatherproof caps Fill pipes must be two feet from building openings Fill pipes must have tamper proof identifying caps IF POWER VENTER IS USED: All outside connections sealed Vent terminal must be three feet above all air inlets within 10ft. Burner air intake is exempted Vent terminal must be four feet from doors and windows. Vent must be one foot above finished grade. Three foot clearance from inside corners. Not above or within three feet of an oil tank. Seven feet above a public walkway.
OUTSIDE TANKS
All UST's and tanks over 660 gallons must be installed as per NFPA 31 2011 edition Tank protected from physical damage Tanks exterior coated with organic alkyd resin or asphalt paint Damaged protective coatings must be recovered Tank does not block means of egress Tank mounted on continuous 4" thick slab that extends 8" beyond tank perimeter Tank is supported by rigid non-combustible supports