VS5M, VS12M, VS50M & DVS50M
HAZARDOUS DUTY DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, DIRECT OR PILOT OPERATED
NFPA SIZE D05 NFPA SIZE D03
VALVE FEATURES • 24” long lead wires. • Ground terminal located in wiring cavity. • Electrical certification in accordance with CSA STD. C22.2 No. 25-1966 for use in Class II; groups E, F, & G hazardous locations. • May be used in locations as defined in the National Electrical Code Class II; Div. 1 & 2; Groups E, F, & G. Designed in accordance with ANSI/NEMA ICS6110.26 Type 9 standards. (Combustible dust environments, i.e. metallic, coal, grain). • CSA Certified (Canadian Std.Assn.). • Same performance curves and specifications as VS5M, VS12M, VS50M or DVS50M valves unless noted below. • These valves are not field-repairable.
NFPA SIZE D08
DeAccelatrol NFPA SIZE D08 TYPICAL ELECTRICAL & RESPONSE TIME SOLENOID CODE* 50L VOLTAGE & VOLTAGE (110/120V FREQUENCY LIMITS 50/60 Hz) VS5M VS12M VS50M, DVS50M
VOLTS - Hz.
MIN. - MAX.
120 - 60 110 - 50 120 - 60 110 - 50 120 - 60 110 - 50
108 - 126 99 - 116 108 - 126 99 - 116 108 - 126 99 - 116
INRUSH CURRENT (AMPS) MAX. 2.50 5.00 6.20 2.50
* Consult factory on other voltages: — VS5M, CS50M; 240V AC, 60HA, 28 WATT; 12 & 24V DC, 24 WATT. — VS12M; 240V AC, 60 HZ, 45 WATT; 12 & 24VV DC, 44WATT.
66
HOLDING HOLDING CURRENT POWER (AMP)
(WATTS)
.56 .69 .91 1.10 .56 .69
28 31 45 43 28 31
RESPONSE TIME (MILLISECONDS) SOLENOID SPRING 12 14 12 12
15 15 15 15
SEE RESPONSE DATA FOR VS50M OR DVS50M VALVES
VS5M, VS12M, VS50M & DVS50M
HAZARDOUS DUTY DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, DIRECT OR PILOT OPERATED SPOOL DESCRIPTION
CODE
SYMBOL
SPOOL FUNCTION
CENTER POSITION CROSSOVER
A
All ports blocked
All ports blocked
A2
All ports blocked
All ports blocked
B
All ports open
All ports open
E
P & A blocked B to T
All ports blocked
F
P blocked A & B to T
P blocked A or B to T
P blocked A & B restricted to T P to A or B T & A or B blocked
P blocked A or B restricted to T P to A or B T & A or B blocked
H
P to A & T B blocked
All ports open
J
P to B A & T blocked
All ports blocked
K
P to B blocked A to T
All ports blocked
L
P to T A & B blocked
All ports open, restricted
N
P to A B & T blocked
All ports blocked
Q
P to B & T A blocked
All ports open
F1
G*
* VS50M G spool available for quantity orders only. Consult factory for price and delivery. NOTES:
Code G or L available on Codes 3 and 5 valves only. Code F1 available on Codes 1, 3 and 5 valves only. Code B not available on Code 1 with D.C. solenoids.
67
VS5M, VS12M, VS50M & DVS50M
HAZARDOUS DUTY DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, DIRECT OR PILOT OPERATED VS5M VALVES AC SOLENOIDS (SINGLE & DOUBLE)
NFPA D03 SIZE SEE MOUNTING SURFACES SECTION FOR INTERFACE PATTERN
ENCLOSURE FOR CLASS ll GROUPS E, F AND G HAZARDOUS DUTY
(195.6) DOUBLE 7.70 SOLENOID (138.2) SINGLE 5.44 SOLENOID (48.3) GROUND 1.90
(42.2) 1.66 MINIMUM CLEARANCE FOR COIL REMOVAL
SCREW ALL VALVE TYPES
SOLENOID "a"
SOLENOID "b"
DIMENSIONS SHOWN IN: (MILLIMETERS) INCHES
1/2-14 NPT ELECTRICAL CONNECTION
HAND TORQUE ONLY FOR SOLENOID NUT
b
(63.8) (68.1) 2.51 2.68 (2) LEAD WIRES FOR EACH SOLENOID APPROX.
(6.4) .25
(1.5) .06
(88.9) 3.5 (66.3) 2.6
(15.0) .59 (22.9) .90
LONG
(45.5) 1.79 ORIENTATION PIN (3.0) DIA. x (3.0) LONG .12 .12
VS12M VALVES
(23.9) .94 MANUAL OVERIDE PIN EACH SOLENOID
NFPA D05 SIZE SEE MOUNTING SURFACES SECTION FOR INTERFACE PATTERN NOTE: "T" OPTION ENABLES MANIFOLD MOUNTING CONNECTION CENTERED ON NAMEPLATE
HAND TORQUE ONLY FOR SOLENOID NUT
MANUAL OVERIDE PIN, EACH SOLENOID
(90.2) 3.55 STD. (92.5) "T" 3.64 (OPTION)
(237.2) DOUBLE 9.34 SOLENOID (170.7) SINGLE 6.72 SOLENOID 1/2-14NPT ELECTRICAL CONNECTION BOTHSIDES (+ TOP ON " T" OPTION )
(39.9) 1.55
ENCLOSURE FOR CLASS ll GROUPS E, F AND G HAZARDOUS DUTY GROUND SCREW ALL VALVE TYPES MINIMUM CLEARANCE (45.7) FOR COIL 1.8 REMOVAL (68.3) 2.69
P
(35.1) 1.38 (69.9) 2.75
(73.4) 2.89
1.78
(9 3.56
(2) LEAD WIRES FOR EACH SOLENOID APPROX. (609.6) 24.00 LONG
68
(31.8) 1.25 (4) MOUNTING BOLTS TORQUE 10-12 lb.-ft. USE 3/16" HEX WRENCH
VS5M, VS12M, VS50M & DVS50M
HAZARDOUS DUTY DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, DIRECT OR PILOT OPERATED VS50M VALVE
DIMENSIONS SHOWN IN: (MILLIMETERS) INCHES
NFPA D08 SIZE SEE MOUNTING SURFACES SECTION FOR INTERFACE PATTERN (13.5) DIA. MTG. .53 HOLES (6)
(6.4) x (6.4) DIA. LOCATING .25 .25 PINS (2)
EXTERNAL PILOT PORT
A
X
(16.7) .66
B
(92.0) 3.62
T
(7.9) .31
Y
P
(2) LOCATING PINS (6.4) .25 DIA.
(11.0) .44
(130.0) 5.12 EXTERNAL DRAIN PORT
(272.0) 10.72 ACCESS TO MOUNTING BOLTS (6) TORQUE TO 40-50 lbs.-ft. USING A 3/8 HEX WRENCH
DVS50M VALVES NFPA D08 SIZE SEE MOUNTING SURFACES SECTION FOR INTERFACE PATTERN
TOP ELECTRICAL CONNECTOR MAY BE ROTATED 180°
(203.5) 8.01 A.C. (234.2) D.C. 9.22 (126.0) 4.96
(63.8) 2.51 A.C. (79.0) D.C. 3.11
MANUAL OVERIDE PIN WITH OPTIONAL INDICATOR LIGHTS
SOLENOID “ b ” (DIRECTIONAL & LOW SPEED) HIGH SPEED ADJUSTMENT (EACH END)
CONTROL ASSY. A
CONTROL ASSY. B
WITH OPTIONAL INDICATOR LIGHTS
(99.6) 3.92
SOLENOID “ b1 ” (ACCEL. & DECEL. CONTROL)
SOLENOID "a" (DIRECTIONAL & LOW SPEED)
(207.8) 8.18 MAX. (250.2) 9.85 MAX.
MINIMUM CLEARANCE FOR COIL REMOVAL (EACH SIDE)
DECEL. ADJUSTMENT . (EACH END)
(271.0) 10.67 (245.6) 9.67 (192.0) 7.56
ACCEL. ADJUSTMENT (EACH END)
(301.5) 11.87 (276.1) 10.87
(222.5) 8.76 (2) AIR BLEEDS
LOW SPEED ADJUSTMENT (EACH END)
(114.3) 4.50
(654.5) MAX. 25.76
CODES 5 & 8 (13.5) DIA. MTG. .53 HOLES (6)
(6.4) x (6.4) DIA. LOCATING .25 .25 PINS (2)
EXTERNAL PILOT PORT
A
X
T
CONTROL ASSY. "B"
B
(92.0) 3.62 P
Y
(130.0) 5.12 EXTERNAL DRAIN PORT
(11.0) .44
(404.2) MAX. 15.91 (463.3) MAX. 18.24
69
VS5M, VS12M,VS50M & DVS50M
HAZARDOUS DUTY DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, DIRECT OR PILOT OPERATED ORDERING INFORMATION SELECT ONE
SELECT ONE
SELECT ONE
SELECT ONE
M
VS
SELECT ONE
G
SELECT ONE
50L
HD
PILOT - DRAIN LOCATION SIZE CODE
DESCRIPTION
5 12 50
NOMINAL 7 GPM NOMINAL 12 GPM NOMINAL 50 GPM
CODE
OPTION A B
CODE
PILOT PRESSURE
DRAIN
1* 2 3* 4
INTERNAL EXTERNAL INTERNAL EXTERNAL
EXTERNAL EXTERNAL INTERNAL INTERNAL
SPOOLS AVAILABLE CODES VS5M VS12M VS50M
FUNCTION
b
1 P T
A B F
A B F
A A2 B
F F1
A B F
A B F
A A2 B
F F1
A A2 B
F F1 G L
Single actuator • 2 position Spring offset a
A B
b
2 P T
Double actuator • 3 position No spring, detented A B
b
a
ALL SPOOLS
3 P T
Double actuator • 3 position Spring centered A B
5 P T
b Spool Center Position
ALL SPOOLS
Single actuator • 2 position Spring centered A B
6
P T
A B F F1
G K L
A B F F1
G K L
b Spool Center Position
N/A
Single actuator • 2 position Spring offset, energize to center
ORDERING INFORMATION:
70
A B F F1
ELECTRICAL OPTIONS
A A2 B F
F1 G L
CODE
OPTION
OMIT
NONE TOP CONNECTION FOR VS12M
T
MECHANICAL OPTIONS CODE
OPTION
OMIT
NONE SINGLE SOLENOID REVERSE ASS’Y. R SOLENOID “A” SUPPLIED ADJUST JJ* PILOT CHOKES BOTH ENDS ADJUST KK* PILOT CHOKES BOTH ENDS CHECK VALVE 70C*† “P” PORT 70 PSI CRACK PRESSURE * Available on VS50M only. † Check valve may be required on VS50M only to ensure adequate pilot pressure to shift spool on internal pilot valve (Code1 or 3) with open center spools (Codes B and L).
N/A
VS5M-2A-GHD-50L VS12M-5F1-GRHD-50L VS50M-3F1-GKK1HD-50L