RadioRA® 2 Visor Controls allow lights, shades / draperies, and other equipment to be controlled from the car with just a touch of a button on a Visor Control Transmitter or a HomeLink® compatible visor control. Up to ten (10) Transmitters can be used with a Visor Control Receiver. The Receiver provides two (2) Contact Closure Inputs (CCI) for integration with other systems and one (1) CCI for security systems. The CCIs can be configured to accept maintained or momentary contact closures. The security input is always a maintained CCI. The Receiver also has four (4) maintained or momentary Contact Closure Outputs (CCO) to control up to four (4) garage doors or motorized gates.
RR-VCRX-WH Visor Control Receiver
Pre-printed and blank labels are included with the Visor Controls for naming scenes or buttons on both the Receiver and the Transmitter.
Model Numbers RR-VCRX-WH*
Visor Control Receiver
RR-VCRX-WHBA*
Visor Control Receiver for Brazil
LR-3B-H-SW**
Visor Control Transmitter
*Only available in White (WH). **Only available in Snow (SW).
www.lutron.com/radiora2
LR-3B-H-SW Visor Control Transmitter
HomeLink and the HomeLink Compatible logo are registered trademarks of Johnson Controls.
Lutron® | 1
product specifications
369-224e
03.10.12
RadioRA 2 Visor Controls ®
Specifications Model Numbers
RR-VCRX-WH, RR-VCRX-WHBA, LR-3B-H-SW
Power
Receiver: 9 V 300 mA DC adapter: Input: 120 V 60 Hz 6.5 W Output: 9 V 300 mA Transmitter: 6 V 10 mA (2 - CR2032, included – 10 year lifetime)
Typical Power Consumption
1.6 W Test conditions: two LEDs on (two presets active), powered by the 9 V adapter supplied, no CCOs or CCIs active.
Regulatory Approvals
DC adapter: UL Listed for U.S. and Canada, NOM Receiver / Transmitter: FCC, IC, COFETEL, ANATEL
Environment
Receiver: Ambient operating temperature: 32 °F to 140 °F (0 °C to 60 °C), 0% to 90% humidity, non-condensing. Indoor use only. Transmitter: Ambient operating temperature: -40 °F to 235 °F (-40 °C to 113 °C), 0%-90% humidity, non-condensing. Meets the Society of Automotive Engineers (SAE) temperature standards.
Communications
Visor Controls communicate with the system through Radio Frequency (RF). The Receiver must be located within 30 ft (9 m) of a Repeater. The typical operating distance between a Receiver and a Transmitter is 150 ft (46 m). System devices operate on frequencies between 431.0 MHz and 437.0 MHz.
ESD Protection
Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2.
Surge Protection
Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits.
Mounting
Mount Receiver on a wall, ceiling, or level surface using the two #6 (M3) screws provided. Clip Transmitter to a vehicle’s visor.
Connections
2 Contact Closure Inputs, 1 security input, and 4 momentary or maintained Contact Closure Outputs.
Warranty
1 Year Limited Warranty. http://www.lutron.com/resiinfo
Design Features Each output can be controlled locally at the Receiver or remotely by a Transmitter or keypad button.
•
The Receiver ‘Keypad’ or ‘Inputs’ buttons can be programmed to light and shades / draperies.
•
2 | Lutron®
Full or Flash security options.
•
T he Transmitter can remotely control the ‘Keypad’, ‘Security Input’, and ‘Outputs’ buttons on the Receiver.
•
24/7 Technical Support—800.523.9466
product specifications
03.10.12
369-224e
RadioRA 2 Visor Controls ®
Dimensions All dimensions are shown as in (mm) Receiver (Side)
Receiver (Front) 6 1⁄4 (159) Visor Control Receiver Security Input
Inputs
Full Flash
Outputs
Keypad
5 1⁄4 (133)
1/4 (6) Visor Transmitter
2 3⁄4 (70)
Learn
Power
Inputs
9V 1
Outputs Full
2 Flash C
1
C
2
C
3
C
Mounting Holes 3 3⁄4 (95)
4
C
1 1⁄16 (27)
4 1⁄4 (108)
Transmitter (Side)
Transmitter (Front)
1 1⁄2 (38)
3 1⁄4 (81)
www.lutron.com/radiora2
3/4 (19)
Lutron® | 3
product specifications
369-224e
03.10.12
RadioRA 2 Visor Controls ®
Mounting Receiver Vertical
Horizontal Ceiling
Wall
#6 (M3) screw recommended (2 included)
Level Surface
Transmitter
Vehicle Visor
4 | Lutron®
24/7 Technical Support—800.523.9466
product specifications
369-224e
03.10.12
RadioRA 2 Visor Controls ®
Operation Receiver
Visor Control Receiver
Input LEDs Display status of Inputs.
Security Input
Inputs
Full Flash
Outputs
Input Buttons Press to test CCI programming.
Keypad
Inputs
Security Input Full
Visor Transmitter
Security Input LEDs Turn on when security mode is activated.
Learn
Flash Power
Inputs
9V 1
2
Outputs Full Flash C
1
C
2
C
3
C
4
C
Outputs
Output LEDs Display which CCOs are active.
Keypad
Keypad Buttons Press to test keypad programming.
Visor Transmitter Learn
Keypad LEDs Display status of lights and shades / draperies programmed to the ‘Keypad’ buttons.
Output Buttons Press to test CCOs. Learn LED Flashes to indicate that the Receiver is in Learn mode.
Security Input Buttons Press and hold to test Security programming.
Learn Button Press and hold for 3 seconds to enter Learn mode.
Labels Place pre-printed or custom labels in depressions to name scenes / buttons.
Transmitter
Labels Place pre-printed or custom labels in depressions to name scenes / buttons
Visor Control Transmitter Buttons Press to activate functions remotely.
www.lutron.com/radiora2
Lutron® | 5
product specifications
369-224e
03.10.12
RadioRA 2 Visor Controls ®
Connections Receiver (Top)
RF range: To repeater 30 ft (9 m) To Transmitter 150 ft (46 m)
Antenna
Receiver (Bottom) Contact Closure Inputs (CCI) Dry contacts only. ON saturation: <1 V at 2 mA OFF leakage: <1 µA at 9 V Minimum pulse time: 40 ms Common - C
Contact Closure Outputs (CCO) Max Voltage / Current: See Relay Contact Ratings below. IEC PELV / NEC® Class 2 Minimum close time: 500 ms 1 - Output 1 C - Common 1 2 - Output 2 C - Common 2 3 - Output 3 C - Common 3 4 - Output 4 C - Common 4
(all inputs)
Security - Full Flash Input 2 - 2 Input 1 - 1
9V
Power Jack (to adapter) IEC PELV / NEC® Class 2
Contact Closure Terminal Blocks Use IEC PELV / NEC® Class 2 cable Maximum 1000 ft (305 m) Each terminal holds up to one 16 AWG (1.0 mm2) or two 18 AWG (0.75 mm2) or smaller wire.
Relay Contact Ratings Voltage Up to 30 V Up to 30 V Up to 60 V 6 | Lutron®
Resistive Load 1A 1A 0.5 A
Inductive Load 0.2 A 0.1 A Do not use. 24/7 Technical Support—800.523.9466
product specifications
369-224e
03.10.12
RadioRA 2 Visor Controls ®
Wiring Diagram Dry Contact Closure Input
C Common Input 2
(e.g. motion sensor)
Security System
O Output 1 C Common 1
Output Device (e.g. garage door)
Security S C Common
www.lutron.com/radiora2
Lutron® | 7
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2 ®
Los controles de visera RadioRA® 2 permiten controlar luces, cortinas y demás equipos desde el automóvil con tan sólo tocar un botón de un transmisor del control de visera o de un control de visera compatible con HomeLink®. Se pueden utilizar hasta diez (10) transmisores con un receptor de control de visera. El receptor cuenta con dos (2) entradas de contacto seco (CCI) para la integración con otros sistemas y una (1) entrada de contacto seco para sistemas de seguridad. Las entradas CCI se pueden configurar para aceptar cierres sostenidos o momentáneos. La entrada de seguridad siempre es sostenida. Además, el receptor tiene cuatro (4) salidas de contacto seco (CCO) sostenidos o momentáneos para controlar hasta cuatro (4) puertas de garaje o portones motorizados.
RR-VCRX-WH Receptor de control de visera
Los controles de visera vienen con etiquetas preimpresas y otras en blanco para identificar escenas o los botones del receptor transmisor.
Números de referencia RR-VCRX-WH*
Receptor de control de visera
RR-VCRX-WHBA*
Receptor de control de visera para Brasil
LR-3B-H-SW**
Transmisor de control de visera
LR-3B-H-SW Transmisor de control de visera
HomeLink y el logotipo HomeLink Compatible son marcas registradas de Johnson Controls.
*Disponible sólo en color blanco (WH). **Disponible sólo en color blanco nieve (SW).
8 | Lutron®
Soporte técnico las 24 horas del día, los 7 días de la semana—800.523.9466
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2 ®
Especificaciones Números de referencia
RR-VCRX-WH, RR-VCRX-WHBA, LR-3B-H-SW
Alimentación
Receptor: 9 V 300 mA Adaptador de CC: Entrada: 120 V 60 Hz 6,5 W Salida: 9 V 300 mA Transmisor: 6 V 10 mA (2 - CR2032, incluidas – vida útil de 10 años)
Consumo típico de potencia
1,6 W Condiciones de prueba: dos indicadores LED encendidos (dos estados predeterminados activos), alimentado por el adaptador de 9 V provisto, sin entradas CCI ni salidas CCO activas.
Certificaciones
Adaptador de CC: listado en UL para EUA y Canadá, NOM Receptor/transmisor: FCC, IC, COFETEL, ANATEL
Condiciones ambientales
Receptor: Temperatura ambiente de operación: 0 °C a 60 °C (32 °F a 140 °F), humedad de 0% a 90%, sin condensación. Sólo para uso en interiores. Transmisor: Temperatura ambiente de operación: -40 °C a 113 °C (-40 °F a 235 °F), humedad de 0% - 90%, sin condensación. Cumple con las normas de temperatura de Society of Automotive Engineers (SAE).
Comunicaciones
Los controles de visera se comunican con el sistema a través de radiofrecuencia (RF). El receptor debe ubicarse a no más de 9 m (30 pies) de un repetidor. La distancia típica de operación entre receptor y transmisor es de 46 m (150 pies). Los dispositivos del sistema funcionan en frecuencias que oscilan entre los 431,0 MHz y 437,0 MHz.
Protección contra descargas electrostáticas (ESD)
Las botoneras se prueban según IEC 61000-4-2 por resistencia a descargas electrostáticas sin daño ni pérdida de memoria.
Protección contra sobrevoltajes
Las botoneras se prueban según IEEE C62,41-1991 por resistencia a sobrevoltajes sin daño ni pérdida de operación. Prácticas recomendadas para transitorios de voltaje en circuitos de potencia de corriente alterna de bajo voltaje.
Montaje
Monte el receptor sobre una pared, el cielo raso o una superficie plana con los dos tornillos M3 (No. 6) suministrados. Sujete el transmisor con el clip a una visera del vehículo.
Conexiones
2 entradas de contacto seco, 1 entrada de seguridad y 4 salidas de contacto seco momentáneo o sostenida.
Garantía
Garantía limitada por un año. http://www.lutron.com/resiinfo
Características de diseño • C ada salida se puede controlar en forma local desde el receptor o en forma remota desde un transmisor o un boton de una botonera. • Los botones de la “Keypad” (botonera) o de “Inputs” (entradas) del receptor se pueden programar para controlar luces y cortinas. • Opciones de seguridad de Permanentemente encendido o Parpadeo.
www.lutron.com/radiora2
• E l transmisor puede controlar en forma remota los botones de la “Keypad” (botonera), de “Security Input” (entrada de seguridad) y de “Outputs” (salidas) del receptor.
Lutron® | 9
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2 ®
Dimensiones Todas las dimensiones se muestran en mm (pulg) Receptor (vista lateral)
Receptor (vista frontal) 159 (6 1/4) Visor Control Receiver Security Input
Inputs
Full Flash
Outputs
Keypad
133 (5 1/4)
6 (1/4) Visor Transmitter
70 (2 3/4)
Learn
Power
Inputs
9V 1
Outputs Full
2 Flash C
1
C
2
C
3
C
4
Orificios de montaje 95 (3 3/4)
C
27 (1 1⁄16)
108 (4 1/4)
Transmisor (vista lateral)
Transmisor (vista frontal)
38 (1 1/2)
81 (3 1/4)
10 | Lutron®
19 (3/4)
Soporte técnico las 24 horas del día, los 7 días de la semana—800.523.9466
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2 ®
Montaje Receptor Vertical
Horizontal Cielo raso
Pared
Se recomienda utilizar tornillos M3 (No. 6) (se incluyen 2)
Superficie plana
Transmisor
Visera del vehículo
www.lutron.com/radiora2
Lutron® | 11
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2 ®
Operación Receptor
Visor Control Receiver Security Input
Inputs
Full
Indicadores LED de entrada Muestran el estado Botones de entrada de las entradas. Presione para comprobar la programación de las entradas de contacto seco.
Flash
Outputs
Keypad
Inputs
Security Input Full
Visor Transmitter Learn
Flash Power
Inputs
9V 1
2
Outputs Full Flash C
1
C
2
C
3
C
Indicadores LED de salida Muestran qué las salidas de contacto seco están activas.
4
C
Outputs
Keypad
Visor Transmitter
Indicadores LED de la botonera Muestran el estado de las luces y cortinas programadas para los botones de la “botonera”.
Botones de salida Presione para comprobar las salidas de contacto seco.
Transmisor
Botones de entrada de seguridad Mantenga presionado para comprobar la programación de seguridad.
Botones de la botonera Presione para comprobar la programación de la botonera.
Learn
Indicador LED de memorización Parpadea para indicar que el receptor está en modo de memorización.
Indicadores LED de entrada de seguridad Se encienden cuando se activa el modo de seguridad.
Botón de memorización Mantenga presionado durante 3 segundos para ingresar al modo de memorización.
Etiquetas Coloque las etiquetas preimpresas o personalizadas en las cavidades para identificar las escenas o los botones.
Etiquetas Coloque las etiquetas preimpresas o personalizadas en las cavidades para identificar las escenas o los botones.
Botones del transmisor de control de visera Presione para activar las funciones en forma remota.
12 | Lutron®
Soporte técnico las 24 horas del día, los 7 días de la semana—800.523.9466
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2 ®
Conexiones Receptor (vista superior)
Alcance de RF: 9 m (30 pies) al repetidor 46 m (150 pies) al transmisor
Antenna
Receptor (vista inferior) Entradas de contacto seco (CCI) Sólo contactos secos. Saturación en estado activo: <1 V a 2 mA Fuga en estado inactivo: <1 µA a 9 V Duración mínima del pulso: 40 ms
Salidas de contacto seco (CCO) Corriente/voltaje máximo: Consulte las especificaciones de los contactos de relé que figuran a continuación. IEC PELV / NEC® Class 2 Duración mínima de cierre: 500 ms
Común - C
(todas las entradas)
Seguridad - Completo Parpadeo Entrada 2 - 2 Entrada 1 - 1
1 - Salida 1 C - Común 1 2 - Salida 2 C - Común 2 3 - Salida 3 C - Común 3 4 - Salida 4 C - Común 4
9V
Enchufe de alimentación (al adaptador) IEC PELV / NEC® Class 2
Conectores de contacto seco Utilice un cable IEC PELV / NEC® Class 2 Máximo: 305 m (1 000 pies) Cada terminal admite hasta un cable de 1,0 mm2 (16 AWG), dos cables de 0,75 mm2 (18 AWG) o cables más pequeños.
Especificaciones de los contactos de relé Voltaje Hasta 30 V Hasta 30 V Hasta 60 V
Carga resistiva 1A 1A 0,5 A
www.lutron.com/radiora2
Carga inductiva 0,2 A 0,1 A No utilizar. Lutron® | 13
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2 ®
Diagrama de cableado Entrada de cierre de Común contacto Entrada 2 seco (por ejemplo: sensor de movimiento)
Sistema de seguridad
14 | Lutron®
Salida 1 Común 1
Dispositivo de salida (por ejemplo: puerta de garaje)
Seguridad Común