ASME PTC 12.2 – 2010 Steam Surface Condensers Performance Test Codes AN AMERICAN NATIONAL STANDARD Three Park Avenue † New York, NY † 10016 USA
A.3 Water Induction Monitoring. 22. A.4 Condition Monitoring. 23. B. Operations, Maintenance, and Training Infrastructure. 24. B.1 Operations. 24. B.2 Maintenance Management. 25. B.3 Training .... rows of stationary and rotating blading which convert
iii Last updated 11/3/2015 Contents Virtual keyboard keeps popping up on Acrobat 11.0.06
Download Troubleshooting Failed QC. Dr Douglas Chesher. Clinical Biochemistry, NSW Health Pathology, Royal. North Shore Hospital. Northern Clinical, School University of Sydney ...
Online lcd tv repair tips - training manual & repair guide Hard To Find LCD TV Repair Info? NOW All LCD Television Repair Info Is Here! #####~Find Out
Sep 1, 2013 ... interrogate the vehicle ECUs, using fault codes to examine the live data,” states Paul Sinderberry,. European product manager ... engines. “I've had a look at the [ Mercedes-Benz]. Actros Euro 6 engine and I've seen a Scania unit, but
Office 365 Troubleshooting Guide ... My Office 365 account is not showing my Yale mail. Be sure to check that you are in the correct account. You likely also have a
Download SURFACE PHENOMENA. Narsimhan, Ganesan. Biochemical and Food Process Engineering, Department of Agricultural and Biological. Engineering, Purdue ...
Trouble-Shooting Checklist for Stairlift. 1. What kind of stairlift ... Does the stairlift make a “beep” when the arm switch is pressed? o Is there ... Remotes. • Point infrared or radio frequency remotes at the unit. Be sure not to cover the top of
Aug 14, 2013 ... the packet. Management traffic. This local traffic is delivered to the FortiGate unit TCP/IP stack and includes communication with the web-based manager, the CLI, the FortiGuard network, log messages sent to ... If the packet is tran
Download Troubleshooting Failed QC. Dr Douglas Chesher. Clinical Biochemistry, NSW Health Pathology, Royal. North Shore Hospital. Northern Clinical, School University of Sydney ...
Download This section focuses on the second major step: problem isolation. (For a more general reference on troubleshooting techniques, refer to Chapter 3, “ Troubleshooting LAN Switching.”) Isolating IP Routing Problems Related to Hosts . The tr
Procure TO. FREE NUMBER 1800 419 4632 at Home Services Legal Quick Links Department Resources 2355 Support About Us Brief Tender ID 256700 Contact Us
Download SURFACE PHENOMENA. Narsimhan, Ganesan. Biochemical and Food Process Engineering, Department of Agricultural and Biological. Engineering, Purdue ...
Their Components To Minimize Oxygen Induced. Corrosion”, EPRI NP-2294. [8]. “Steam Suace Condensers: Performance Test Codes”,. ASME PTC 12.2-2010 Revision of ASME PTC 12.2 -. 1998 (R2007). [9]. Richard E. Putman and Dr. Joseph W. Harpster, “The. Meas
1. mesin pembakaran luar seperti: mesin uap dan turbin. 2. suplai tekanan rendah bagi kerja proses di industri seperti industri pemintalan, pabrik gula dsb
Science Guidelines for STEAM Fair ... Have you ever wanted to build your own simple machine? A Rube Goldberg machine is a ... squeeze oranges for orange juice
Micro-Tsunami Quick Start Guide Page 1 All Aboard! Overview Congratulations on the purchase of your SoundTraxx® Micro-Tsunami® Digital Sound Decoder™
INTERMITTENT CONCERN TROUBLESHOOTING . Vibration Method • If a malfunction occurs or becomes worse while driving on a rough road or when the engine is vibrating,
RECTIFIER COMPONENTS • Cabinet - protects the rectifier components from the elements • Circuit Breaker - serves as an on - off switch and overload protection
Prior to this she was a software engineer and engineering manager of PBX Call Center products at Nortel. Networks. Her earlier ... has been focusing on PBX/ Enterprise communication systems. He spent more ...... appendix provides a cheat sheet that s
Chrysler Communications Problems 708 Appendix B • Loss of power to the PCM —Use the scan tool Read IGN(+) at DLC test to verify battery voltage is supplied to the
ABSTRACT This project was aimed at developing a program through which the steam system headers within Caltex’s Lytton Refinery, Brisbane, could be quantified
Steam Trap Management System provides software, hardware and service that can solve problems in your steam system. From initial preparations and inspection route
Troubleshooting Steam Surface Condensers
Troubleshooting Steam Surface Condensers HTS Forum 12 September 2012
Steam Condenser Troubleshooting What is a steam surface condenser? Troubleshooting tools Is there a problem? Fault diagnosis Locating air leaks Condenser monitoring
Condenser Vacuum Pumps Condensers are provided with vacuum pumps/ejectors The condenser creates the vacuum, NOT the vacuum pump Vacuum pumps are there to extract air and pump it up to atmospheric pressure A startup ejector (“hogger”) is provided to create a rough vacuum in order to start the turbine
Is There a Problem? Plant operator is typically concerned about turbine exhaust pressure First task is to establish whether the exhaust pressure is higher than expected Two issues: – The plant measurement may not be accurate – The turbine exhaust pressure will naturally vary with plant load and CW temperature
Identifying Faults Three most common causes of condenser performance problems: – Air accumulation in condenser – Cooling water fouling – Reduced cooling water flow
Unfortunately, all have the same effect on condenser performance: – Increase in turbine exhaust pressure
Condenser Temperature Profile Temperature, °C
Temperature approach
Tsat CW out
∆T
CW in
Condenser duty
Duty, kW
What is the response to the three most common faults?
No air Air “blanket” Steam condenses easily Steam must diffuse Minimal sub-cooling Sub-cooling The presence of air reduces the heat transfer rate
Fault Diagnosis To differentiate between the various causes of high turbine exhaust pressure, examine temperatures, not pressure: – CW flow reduction is indicated by increase in CW temperature rise – Fouling is indicated by increase in temperature approach (Tsat – CW out) – Air accumulation is indicated by increase in temperature approach and increased ∆T between Tsat and condensate temperature
Confirming and Fixing Faults Reduction in cooling water flow is caused by fouling or a pump fault Fouling can be confirmed by inspection (most condensers have divided waterboxes) Air accumulation is a more complex issue For air to accumulate: – Vent rate too low (vacuum pump fault) – Ingress rate too high (air leak)
Vacuum Pump Faults Generally rare, although original specification may be deficient For LRVPs check seal water temperature For steam ejectors check motive steam pressure (too high or too low) Detailed troubleshooting outside scope of this presentation
Air Leaks Some in-leakage is expected (hence the vacuum pump) Vacuum pump is usually over-specified (especially if to HEI Standard) Once excess capacity is used, any additional in-leakage will cause turbine exhaust pressure to rise Vacuum boundary must be maintained
Air Leakage Points Turbine burst disc Expansion joint
Tracer Gas Testing - Tips Always check the detector is working before you start Avoid false indications: – Helium: work from top to bottom – Halogen: work from bottom to top – Time the response
Consider testing under low load conditions: – The vacuum boundary is more extensive at low loads
Case Study 200MW electrical generation unit in Ireland High turbine exhaust pressure on startup after outage, close to turbine trip point Outage scope had included: – Condenser cleaning – LP turbine rotor removal
Heat balance indicates full CW flow Hotwell temperature inconclusive
Case Study - Actions Evidence suggests air leak High probability of leak at turbine shaft seals Helium testing ordered to confirm diagnosis: – – – –
Warranty issue Shutdown required to repair Which shaft seal is leaking? Other leaks?
Case Study - Results Leakage at both turbine shaft seals confirmed Additional leakage also found at: – Turbine bursting disc – Cracked weld on pipe – Plugged connection on condenser shell
Resolution of non-shaft leaks moved turbine pressure away from trip point without shutdown
Condenser Monitoring Critical situations can be avoided by regular monitoring Monitoring pressure not very useful Monitor key temperature differences: – (CW out – CW in) – (Tsat – CW out) – (Tsat – Thotwell)
Perform vacuum decay testing – Isolate vacuum pump and measure rate of pressure increase