MA Series Rev. 7.07
C
US
Conforms to EN1088, EN292, EN60204-1 CSA approved
safety interlock switches
G
MA Series
Magnetically Actuated Safety Interlock Switches ■
■
■
Large selection—choose from a large selection of contact configurations housed in plastic to satisfy most application requirements NEMA 6 enclosure enables the MA Series switches to satisfy most application requirements (MA 3, 4, 5 are NEMA 4) Misalignment tolerant—the non-contact actuation of the MA Series switches makes them very tolerant to misalignment of up to 10 mm (0.39 in.)
■
■
Variety of terminations—select from various cable lengths or terminal strip termination for easy installation. Cable connector available on selected models. Long life—the MA Series safety interlock switches are designed for a minimum of one million actuations
A N
G78
Go to the Engineering Guide For in-depth information on safety standards and use.
For More Guarding Products See Section N for safeguarding cutting and turning machines
MA Series
■
Actual Size
G safety interlock switches
■
Applications
Typical applications are on sliding guard doors or swinging guard doors.
G79
MA Series
■
Operation Mounting Examples
Operating Principle
Contact Arrangement mA-1, 5, 6, 9, 10, 11, 12, 13, 14, 16
mA-2, 4, 11, 12, 13, 14, 16
Door Closed, Machine RUN 2mm SLIDING DOOR
mA-3, 11, 13, 16, 20
Door Closed, Machine RUN
safety interlock switches
G
Encapsulated in the MA Series is a unique 2mm high-power industrial reed which is de-rated 2mm by a non-resetable overload protection circuit depending on switch DOOR type. On presenting SLIDING the actuator to the switch, the high intensity magnetic field from the actuator causes the contacts to close. On removing the actuatorMin 50mm 2mm (opening the door), the safety contacts open, isolating the machine. Switch Switch
✘
✔
✘
✔
Actuator
2mm
SLIDING DOOR
2mm Door 2
Door 1
Actuator
✘
✔
Switch Actuator
Door 1
mA-11, 13, 15, 16, 21
Actuator
Min 50mm
Switch
Door Closed, Machine RUN
Min 50mm
Door 2
It is advisable, where possible, to mount the switch and actuator on non-ferrous materials otherwise it may affect the operating distances.
Door Closed, Machine RUN
Switch
Switch
Actuator
Actuator
Door 1
Door 2
Door Open, Machine STOP, Door Covering Switch No access to switch thus preventing attempts to defeat the interlock
2mm SLIDING DOOR
SLIDING DOOR
Wherever possible the units should be mounted so that no access can be obtained to the switch when the guard door is open, thus preventing attempts to defeat the safety system.
Door Closed, Machine RUN
Door Open, Machine STOP, Door Covering Switch
No access to switch thus preventing attempts SLIDING DOOR to defeat the interlock Door Closed, Machine RUN
2mm
DING DOOR
2mm
Mounting Brackets can be used SLIDING DOOR ✎ Universal with this product. See page G241 for details.
G80
A
Go to the Engineering Guide
Door Open, Machine STOP, Door Covering SwitchFor in-depth information on safety standards and use. No access to switch For More Guarding Products thus preventing attempts SLIDING DOOR See Section N for safeguarding to defeat the interlock cutting and turning machines
N
MA Series
■
Specifications
MA-11, 12, 13, 14, 15, 16
(UL and C-UL pending)
Specifications are subject to change without notice. Note: The safety contacts of the Omron STI switches are described as normally closed (N/C)— i.e., with the guard closed, actuator in place, and the machine able to be started.
G81
G safety interlock switches
Electrical All Models Unless Indicated Safety Contacts: AC models MA-1 thru 6, 10, 11, 12, 13, 16 — 1 N/C MA-11, 13, 16, 21 — 2 N/C DC models MA-9, 11, 12, 13, 14, 16 — 1 N/C MA-11, 13, 15, 16, 20, 21 — 2 N/C Safety Contact Operating Distance: Make 7-12 mm (0.28-0.47in.); Break 12-25 mm (0.47-0.98 in.) Auxiliary Contacts: MA-2, 4, 11, 12, 13, 14, 15, 16, 21 1 N/O MA-3 1 N/C Aux. Contact Operating Distance: MA-2, 4, 16, 21 Make 8-13 mm (0.39-0.51 in.); Break 8-10 mm (0.31-0.39 in.) MA-3 Make 21 mm (0.83 in.); Break 24 mm (0.94 in.) Safety Rated Voltage: AC models: All except MA-10 230 VAC AC model: MA-10 110 VAC DC models 30 VDC Safety Rated Current: AC models: All except MA-3 2 A, fuse externally 1.6 A quick acting AC model: MA-3 3 A, fuse externally 2.5 A quick acting DC models: All except MA-15 1 A, fuse externally 800 mA quick acting DC model: MA-15 0.3 A max., fuse externally 0.2 A quick acting Internal Fuse AC models 2 A fast acting DC models 1 A fast acting External Fuse (Customer Supplied) AC models 1.6 A fast acting DC models: All except MA-15 0.8 A fast acting Electrical Life: 1 x 106 Mechanical—Special Safety Reed Safety Aux. Closing Time: 3.0 mS 0.5 mS Drop-Out Time: 2.1 mS 0.3 mS Bounce Time: 0.7 mS 0.7 mS Shock: 10 G 10 G Vibration: 10 G, 50 to 100 Hz Mechanical Mounting: Any position Case Material: Molded ABS Actuator Material: Molded ABS Wiring Connection: Various lengths or male M12 micro connector Weight: 384 g (14 oz.) Color: Red Mechanical Life: 10 x 106 Environmental Protection: MA-3, 4, 5 IP65 (NEMA 4) All models except MA-3, 4, 5 IP67 (NEMA 6) Operating Temperature: MA-11, 12, 13, 14, 15, 16 -10 to 55°C (14 to 131°F) All models except: MA-11, 12, 13, 14, 15 -10 to 65°C (14 to 149°F) Compliance Standards: EN1088, EN292, EN60204-1 Approvals/Listings: CE marked for all applicable directives MA-1, 2, 3, 4, 5, 6, 9, 10, 20, 21 cCSAus (UL and C-UL pending)
MA Series
■
Application Diagram
Typical Application of MA Series with a Safety Monitoring Relay 24 VAC/DC, 110 VAC or 230 VAC K1 (AUX) START
MOMENTARY PUSH BUTTON
L1 L2 L3
K2 (AUX)
L1 L2 L3
STOP
BLUE
S11
S21
13
23
relay control and fault monitoring
Power supply (S11 = 24 V)
FUSE
GUARD CLOSED
safety interlock switches
+
K1
K2
MA SERIES INTERLOCK SWITCH
+
K2
K1
BROWN
CONTACT PROTECTION e.g. THERMAL CUT OUT
G
A1
Sr101A
EB SERIES
A2
LATCHING E-STOP BUTTON
14
FUSE
24
FUSE K1
K2
M
CONTACT PROTECTION e.g. THERMAL CUT OUT
MOMENTARY PUSH BUTTON
M
a full explanation of the circuit operating principle and fault detection, see ✎ For “Common Circuit Examples” in the Engineering Section of this catalog. Pin Assignments with Connector Option MA-2 N/C Safety
Pin 3 same as Blue lead
N/C Safety
Pin 2 same as Green lead
N/O Auxiliary
Pin 4 same as Yellow lead
N/O Auxiliary
MA-6 and MA-9
N/C Safety
Pin 1 same as Brown lead
N/C Safety
Pin 3 same as Red lead
N/C Safety
Pin 3 same as Blue lead
N/C Safety
Pin 2 same as Red/Black lead
N/C Safety
Pin 2 same as White lead
N/C Safety
Pin 4 same as Red/White lead N/C Safety
Pin 4 same as Black lead
N/C Safety
Pin 1 same as Red/Blue lead
Pin 5 same as Red/Yellow lead N/O Auxiliary
Pin 1 same as Brown lead
N/C Safety
Pin 3 same as Blue lead
N/C Safety
Pins 2 & 4 not used
MA-20
MA-15, 21
Pin 1 same as Red lead
Pin 6 same as Green lead
N/O Auxiliary
A N
G82
Go to the Engineering Guide For in-depth information on safety standards and use.
For More Guarding Products See Section N for safeguarding cutting and turning machines
MA Series
■
Dimensions — mm/in.
mA-1, 2, 20, 21
4 0.16
mA-11 15-19 0.6-0.75
5 0.20
30 1.18
=
5 0.2
= 8 0.31 = =
= =
30 1.18
60 2.36
=
ActUAtOr
69 2.72
SWitch
38 1.5
6 0.25
25 0.98
30 1.18
36 1.42
80 3.15
30 1.18
57 2.24
45 1.77
7 0.28
= 19.5 0.77
G
18 0.71
=
8 0.31 =
17 0.67
42 1.65
2 0.08
76 2.99
60 2.36
80 3.15
5 0.2
=
24 0.94
27 1.06
15 0.6
5 0.2
4 0.16
57 2.24
38.5 1.52
=
ActUAtOr
4.5 0.18
mA-13
18 0.71
=
36 1.42
=
78 3.07
24 0.94
24 0.94
SWitch
30 1.18
=
87 3.43
ActUAtOr
SWitch
ActUAtOr
SWitch
ActUAtOr
mA-14 / mA-15 mA-6, 9, 10, 16 7 0.28 54 2.13
84 3.31 46 1.81 6 0.24 19 0.75
12 0.47 46 0.81
7 0.28
SWitch
4 0.16
52 2.05
19 0.75
19 0.75
7 0.28
4.5 0.18
4.5 0.18
22 0.87
28 1.10
= 73 2.87
4 11 0.16 0.43 19 0.75
82 3.23
73 2.87
=
4.5 0.18
ActUAtOr
6.4 0.25
Ø4.2 0.165 Ø8.1 0.32
= = 4.5 0.18
3 0.12
14 0.55 SiDe VieW
G83
safety interlock switches
mA-3, 4, & 5 6 0.25
5 0.2
4.5 0.18
16.5 0.65
7 0.28
4 = 0.16
19.5 0.77
SWitch
50 1.97
4 0.16
=
mA-12
2 hOleS 4 thrU
16 0.63
63 2.48
2 0.08
76 2.99
8 0.31
15 0.6
19.5 0.77
5 0.2
=
2 0.08
76 2.99
60 2.36
7.5 0.29
15 0.6
=
= 5 0.2
17 0.67
MA Series
Part No. 44507-0390 44507-0380 44507-0370 44507-0650 44507-0100 44507-0200 44507-0320 44507-0220 44507-0620 44507-1110 44507-1120 44507-1130 44507-1131 44507-1140 44507-1210 44507-1220 44507-1310 44507-1320 44507-1330 44507-1340 44507-1341 44507-1410 44507-1420 44507-1540 44507-1541 44507-1549 44507-1610 44507-1611 44507-1620 44507-1621 44507-1630 44507-1631 44507-1640 44507-1641 44507-0340 44507-0630 44507-0270 44507-0280 44507-0290 44507-0350 44507-0360 44507-0670 44507-0700 44507-0710 44507-0711 44507-0712 44507-0713 44507-0714 44507-0715 44507-0716
G safety interlock switches
Model Contacts Wiring Entry DC ONLY 1 N/C + 1 N/O 4 m cable, pre-wired MA-2DPC4 MA-2DPC10 1 N/C + 1 N/O 10 m cable, pre-wired 1 N/C + 1 N/O 15 m cable, pre-wired MA-2DPC15 MA-2DPCC 1 N/C + 1 N/O Connector, Brad Harrison 1 N/C 2 m cable, pre-wired MA-9DPC2 (24 VDC only) MA-9DPC4 (24 VDC only) 1 N/C 4 m cable, pre-wired MA-9DPC6 (24 VDC only) 1 N/C 6 m cable, pre-wired MA-9DPC10 (24 VDC only) 1 N/C 10 m cable, pre-wired MA-9DPCC (24 VDC only) 1 N/C Connector, Brad Harrison MA-11DP10C3 1 N/C 3 m cable, pre-wired 1 N/C + 1 N/O 3 m cable, pre-wired MA-11DP11C3 MA-11DP20C3 2 N/C 3 m cable, pre-wired 2 N/C 5 m cable, pre-wired MA-11DP20C5 MA-11DP21C3 2 N/C + 1 N/O 3 m cable, pre-wired 1 N/C 3 m cable, pre-wired MA-12DP10C3 MA-12DP11C3 1 N/C + 1 N/O 3 m cable, pre-wired 1 N/C 3 m cable, pre-wired MA-13DP10C3 MA-13DP11C3 1 N/C + 1 N/O 3 m cable, pre-wired 2 N/C 3 m cable, pre-wired MA-13DP20C3 MA-13DP21C3 2 N/C + 1 N/O 3 m cable, pre-wired MA-13DP21C10 2 N/C + 1 N/O 10 m cable, pre-wired 1 N/C 3 m cable, pre-wired MA-14DP10C3 MA-14DP11C3 1 N/C + 1 N/O 3 m cable, pre-wired 2 N/C + 1 N/O 3 m cable, pre-wired (300 mA max.) MA-15DP21C3* MA-15DP21C5* 2 N/C + 1 N/O 5 m cable, pre-wired (300 mA max.) 2 N/C + 1 N/O Connector, Brad Harrison MA-15DP21CC* MA-16DP10C3 (DC only) 1 x N/C 3 m cable, pre-wired 1 x N/C 6 m cable, pre-wired MA-16DP10C6 (DC only) MA-16DP11C3 (DC only) 1 x N/C + 1 N/O 3 m cable, pre-wired 1 x N/C + 1 N/O 6 m cable, pre-wired MA-16DP11C6 (DC only) MA-16DP20C3 (DC only) 2 x N/C 3 m cable, pre-wired 2 x N/C 6 m cable, pre-wired MA-16DP20C6 (DC only) MA-16DP21C3 (DC only) 2 N/C + 1 N/O 3 m cable, pre-wired 2 N/C + 1 N/O 6 m cable, pre-wired MA-16DP21C6 (DC only) MA-20DPC4 (24 VDC only) 2 N/C 4 m cable, pre-wired MA-20DPCC (24 VDC only) 2 N/C Connector, Brad Harrison MA-21DPC2 (24 VDC only) 2 N/C + 1 N/O 2 m cable, pre-wired MA-21DPC4 (24 VDC only) 2 N/C + 1 N/O 4 m cable, pre-wired MA-21DPC6 (24 VDC only) 2 N/C + 1 N/O 6 m cable, pre-wired MA-21DPC10 (24 VDC only) 2 N/C + 1 N/O 10 m cable, pre-wired MA-21DPC15 (24 VDC only) 2 N/C + 1 N/O 15 m cable, pre-wired MA-21DPCC 2 N/C + 1 N/O Connector, Brad Harrison Spare Actuator (1–5 & 20, 21), Red ABS Plastic Spare Actuator (6, 9 & 10), Red ABS Plastic Replacement Actuator for MA-11, Red ABS Plastic Replacement Actuator for MA-12, Red ABS Plastic Replacement Actuator for MA-13, Red ABS Plastic Replacement Actuator for MA-14, Red ABS Plastic Replacement Actuator for MA-15, Red ABS Plastic Replacement Actuator for MA-16, Red ABS Plastic Accessories and Cables with Mating Connectors (see page G238)
*MA-15 switches are not compatible with the following Omron STI safety relays: SR203M, SR203AM, SR208AD, SR209AD and all Legacy Relays.
= New product
G85