Distillation Column Flooding Predictor - TexasIOF Home

-What is the Distillation Column Flooding Predictor ... TEST PLAN -Project Scheduling ... condenser reboiler bottoms pump accumulator...

7 downloads 401 Views 9MB Size
Distillation Column Flooding Predictor STS-AIChE Energy Forum March 3, 2005 J. Christopher Lewis, UT Austin George E. Dzyacky, 2ndpoint L.L.C. © 3/05

J. Christopher Lewis Distillation Column Flooding Predictor

INTRODUCTION ¾ ¾ ¾ ¾ ¾

Background Technology Results Conclusions Acknowledgements

J. Christopher Lewis Distillation Column Flooding Predictor

BACKGROUND -The Inventor ¾

George Dzyacky ¾ ¾

25 yrs experience in petrochemical industry Obtained patent in July 1998 ¾

¾

U.S. Patent number: 5,784,538

Technology has operated on FCC, FCC main fractionators, stripper columns, and H2S scrubber columns

J. Christopher Lewis Distillation Column Flooding Predictor

TECHNOLOGY

-What is the Distillation Column Flooding Predictor (DCFP)? ¾

¾

¾

Control strategy that uses pattern recognition of process variables to prevent the column from flooding Non-intrusive signal processing technology A means of increasing throughput, reducing bottlenecks, and in some cases improving efficiency

J. Christopher Lewis Distillation Column Flooding Predictor

TECHNOLOGY

-What are the applications? ¾

Approximately 40,000 distillation columns in the U.S. alone ¾

¾

¾ ¾

10% of these columns experience periodic flooding Many of these towers are chronic flooders

Tray Towers Packed Towers

J. Christopher Lewis Distillation Column Flooding Predictor

TECHNOLOGY -Is it proven? ¾

¾

DCFP utilized in two closed loop FCC absorber columns DCFP used as an advisory system on three other columns ¾ ¾

¾

Two FCC Main Fractionator Columns H2S Amine Stripper

DCFP implemented at the University of Texas on a tray tower and on a packed tower

J. Christopher Lewis Distillation Column Flooding Predictor

TECHNOLOGY

-Why is the DOE interested in this technology? ¾

DOE 2020 Strategy ¾

¾ ¾

DCFP could reduce energy consumption in the US by 9.4 Trillion BTU by 2020

Industrial/Academic partnership Viable technology

J. Christopher Lewis Distillation Column Flooding Predictor

TECHNOLOGY

-Why should I be interested in this technology? ¾

¾

¾ ¾ ¾

Reduces downtime associated with column flooding Increases capacity and in some cases efficiency Effective on a variety of process Low capital and maintenance costs BOTTOM LINE: $$$$

J. Christopher Lewis Distillation Column Flooding Predictor

Tray Column

entrainment

efficiency

flooding weeping

0

0.2

0.4

0.6

fraction of flood

0.8

1

J. Christopher Lewis Distillation Column Flooding Predictor

HETP, in

Packed Column

FLOOD POINT

F-Factor, (ft/s)(lb/ft3)0.5

J. Christopher Lewis Distillation Column Flooding Predictor

TECHNOLOGY -How does it work? ¾

¾

¾

¾

DCFP uses existing DCS to calculate the derivatives of process variables DCFP compares derivative values to criterion entered by control engineers on site DCFP relaxes column severity by lowering the reboiler duty or another control mechanism DCFP enables the column to operate more efficiently and with more stability

J. Christopher Lewis Distillation Column Flooding Predictor

TECHNOLOGY -What is the key? ¾

“Critical Constants” ¾

¾

Discreet derivative values that are determined empirically Comparison of current derivative values to the critical constants ¾ ¾

Simultaneous occurrence Values exceed user entered criteria

J. Christopher Lewis Distillation Column Flooding Predictor

TECHNOLOGY -example

Temporary change in Overhead Flow 40 MSQFD 0 MSQFD

Numerous changes in tower variables, and all within normal alarm limits.

1 Hr.

0 Hr.

Temporary change in Delta Pressure 100 psig 0 psig 1 Hr.

0 Hr.

Temporary change in Bottom Temperature 400 deg 0 deg 1 Hr.

0 Hr.

Temporary change in Level or Bottom Flow 100% 0% 1 Hr.

0 Hr.

J. Christopher Lewis Distillation Column Flooding Predictor

TECHNOLOGY

-pre-flood oscillations within normal alarm limits Temporary change in Overhead Flow 40 MSQFD 0 MSQFD 1 Hr.

0 Hr.

Temporary change in Delta Pressure 100 psig 0 psig 1 Hr.

0 Hr.

Temporary change in Bottom Temperature 400 deg 0 deg 1 Hr.

0 Hr.

Temporary change in Level or Bottom Flow 100% 0% 1 Hr.

0 Hr.

J. Christopher Lewis Distillation Column Flooding Predictor

TECHNOLOGY

-DCFP Column Variables

12:15 12:40 13:10 13:30

J. Christopher Lewis Distillation Column Flooding Predictor

TECHNOLOGY

-DCFP Derivative Values

J. Christopher Lewis Distillation Column Flooding Predictor

PHASE 1 – Exploratory Work -UT Austin SRP Pilot Plant

J. Christopher Lewis Distillation Column Flooding Predictor

PHASE 1 – Exploratory Work -UT Austin SRP Pilot Plant ¾

Experimental Work ¾ ¾ ¾ ¾ ¾

Total reflux system Cyclohexane/n-Heptane mixture 24 psia Trays Structured Packing

J. Christopher Lewis Distillation Column Flooding Predictor

PHASE 1 – Exploratory Work -UT Austin SRP Pilot Plant – CONCLUSIONS ¾

DCFP validated by exploratory experimental work at SRP ¾

Operated at 99% of measured flood ¾

¾ ¾ ¾

Trays and structured packing

Maintained efficiency Further optimization necessary Easy implementation on SRP’s FisherRosemount Delta V DCS

J. Christopher Lewis Distillation Column Flooding Predictor

PHASE 2 – DOE Grant - Description of DOE Proposal ¾

$934,000 funding (50% DOE – 50% industrial sponsors) ¾

¾ ¾ ¾

¾ ¾

UT Austin, Center for Energy and Environmental Resources Shell Global Solutions (US) Motiva Enterprises, LLC Emerson Process Management/Fisher-Rosemount Systems, Inc. CDTech 2ndpoint

J. Christopher Lewis Distillation Column Flooding Predictor

PHASE 2 – TEST PLAN -Project Scheduling ¾ ¾

2 year funding period Goals and Objectives ¾ ¾ ¾

¾

Pilot Plant Demonstration—UT Austin Dynamic Model Development—UT Austin Commercial Scale Validation—Motiva Refinery, Norco, LA Commercialization

J. Christopher Lewis Distillation Column Flooding Predictor

PHASE 2 – Pilot Plant Test Work -UT Austin SRP Pilot Plant ¾

Dynamic holdup tests using 18” PVC Air/Water column ¾

¾

Column modifications

Finite reflux tests using 18” distillation column ¾ ¾ ¾

Significant equipment modification/upgrade Trays Packing

J. Christopher Lewis Distillation Column Flooding Predictor

PHASE 2 – Pilot Plant Test Work -

The SeparationsResearch Program UTAustin 08/21/2001

-Dynamic Holdup Experimentation

Chris Lewis

AIR OUTLET

DRW#03082120011

Optional Demister

Distributor (3C for flows up to 15 gpm/ft2, 4C for flows over 15 gpm/ft2)

PressureDrop Transmittercalibrated from 0-30 in H2O DPC packedheight

AIR BYPASS

Packing Support Rod

AirBlower

AIR INLET

VSD

LiquidRecycle Variable Speed Drive (VSD) for motor speed

Liquid Tank

Liquid Pump

VSD

J. Christopher Lewis Distillation Column Flooding Predictor

DISTILLATION COLUMN 18" TRAY SPACING

FC203

condenser

T20710

accumulator LT203

T2073 PDT251

T2071

reboiler

Condensate

LT204

bottoms pump

reflux pump

J. Christopher Lewis Distillation Column Flooding Predictor

DISTILLATION COLUMN 18" TRAY SPACING

FC203

condenser

T20710

accumulator FC200

LT203

T2073 PDT251

feed tank FC204

FC201 T2071

reboiler

Condensate

LT204

reflux pump

bottoms pump feed pump

LT600

J. Christopher Lewis Distillation Column Flooding Predictor

Phase 2 – Control Methodology ¾

¾

¾ ¾ ¾ ¾ ¾ ¾

Temperature control (top tray/top packing) – Reflux Flow Temperature control (bottom tray/bottom packing) – Steam Flow to Reboiler Feed Flow Rate Feed Temperature Bottoms Level Bottoms Temperature Accumulator Level Column Pressure

J. Christopher Lewis Distillation Column Flooding Predictor

Phase 2 – Results COMPOSITION (C6) RUN

PREDICTOR

FLOOD

FEED RATE PRESS DRP REFLUX RATIO (gpm)

(in H2O)

FEED

TOP

BOT

(%)

(%)

(%)

1

no

no

7.02

28.00

0.96

23.12

53.87

14.49

2

no

no

7.03

26.50

0.68

25.06

53.22

14.29

3

no

no

7.00

27.55

0.76

25.42

53.53

13.48

4

no

yes

7.11

60.40

0.72

24.68

49.75

13.55

5

yes

no

7.11

34.10

0.92

22.79

53.97

14.87

6

yes

no

7.25

36.58

0.89

21.27

54.25

15.59

7

yes

no

7.24

38.26

0.85

21.75

53.39

15.16

8

yes

no

7.25

29.62

0.77

23.68

53.00

14.72

9

yes

no

7.35

38.83

0.78

22.77

53.06

14.93

10

yes

no

7.44

40.34

0.89

21.94

52.79

14.66

11

yes

yes

7.55

49.10

0.96

20.35

51.55

15.73

J. Christopher Lewis Distillation Column Flooding Predictor

RUN 1

Distillation Column Overview for 7.03gpm feed rate (maximum controllable loading with the Flooding Predictor in STANDBY). Curve 3 represents the pressure drop for this trend.

J. Christopher Lewis Distillation Column Flooding Predictor

RUN 4

Distillation Column Overview for 7.11gpm feed rate (flood point with Flooding Predictor in STANDBY). Curve 3 represents the pressure drop for this trend.

J. Christopher Lewis Distillation Column Flooding Predictor

RUN 9

Distillation Column Overview for 7.35gpm feed rate (Flooding Predictor in ACTIVE). Curve 3 represents the pressure drop for this trend. The dips in the pressure drop represent Flooding Predictor control.

J. Christopher Lewis Distillation Column Flooding Predictor

RUN 9

Distillation Column Flooding Predictor for 7.35gpm feed rate (Flooding Predictor in ACTIVE). Curves 5 and 6 represent the Flooding Predictor response.

J. Christopher Lewis Distillation Column Flooding Predictor

RUN 11

Distillation Column Overview for 7.55gpm feed rate (Flooding Predictor in ACTIVE). Curve3 represents the pressure drop.

J. Christopher Lewis Distillation Column Flooding Predictor

Phase 2 – DCFP Conclusions ¾

¾

¾

Prevented tower flooding in both trays and structured packing Residence time affects critical constant values 6% increase in tray capacity while maintaining overhead and bottom compositions

J. Christopher Lewis Distillation Column Flooding Predictor

ACKNOWLEDGEMENTS -DCFP Project ¾ ¾ ¾ ¾ ¾ ¾ ¾

U.S. Department of Energy Motiva, LLC Fisher-Rosemount Shell Global Solutions CDTech 2ndpoint CEER, UT Austin

J. Christopher Lewis Distillation Column Flooding Predictor

BACKGROUND

-What is a column flood? ¾

Entrainment (Jet) Flooding ¾

¾

Downcomer Backup Flooding ¾

¾

Occurs when the upward vapor velocity is high enough to suspend a liquid droplet

Occurs when the backup of aerated liquid in the downcomer exceeds the tray spacing

Mass Transfer Flooding ¾

Occurs when the liquid and vapor are not properly distributed (packed tower)

J. Christopher Lewis Distillation Column Flooding Predictor

BACKGROUND

-What does a flood look like?

Kister, Henry Z., Distillation Design, McGraw-Hill, Inc., New York, 1992, p. 268