LM-79 Test Report
NVLAP Lab Code: 100398-0 Test Request Number 0980098
Lamp specifics: Luminaire Used: Luminaire Lamp Type: Lamp Test Requester New Product: Sample Size Requester: Date of Tests Curent Burn Time Sample Size: RatedofLumens Date Tests:
none none LPL-W18-120C-930 / 78875 LPL-W18-120C-930 E.Z. Cola 1 1 E.Z. Cola 10/06/2009 0 hr 10/06/2009 300 Lumens 300 Lumens
RatedWatts Voltage: / RatedOrientation CCT: Rated Voltage Orientation: Beam Angle Current burnBeam time: Center CCT
6.75 Watts VBD 12 V DC approx. 120 deg na 3000 K
Test Purpose: Electrical and Photometric tests as required by IESNA LM-79 test standard
Standards used: IESNA LM-16-1995 Practical Guide to Colorimetry of Light Sources IESNA LM-20-1994 Photometric testing of reflector type lamps IESNA LM-58- 1994 Spectroradiometric Measurements IESNA LM-79-2008 Approved method for the Electrical and Photometric Measurements of Solid-State Lighting Products CIE Pub. 13.3-1995 Method of measuring and Specifying Color Rendering of Light Sources CIE Pub. 15-2004 Method of measuring and Specifying Color Rendering of Light Sources ANSI C82.2-2002 Ballast for Fluorescent Lamps-Methods for Measurement ANSI C82.77-2002 Harmonic Emission Limits- Related Power Quality Requirements for Lighting Equipment
Disclaimers: This report contains data that are not covered by the NVLAP accreditation. The measurement laboratory is currently accredited by NVLAP to all the standards under the Standards used section except LM-79. The accreditation to LM-79 is currently in progress. This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government. The laboratory that conducted the testing detailed in this report had been Qualified, Verified, and Recognized for LM-79 Testing for ENERGY STAR for SSL by US DOE's CALiPER program. http://www1.eere.energy.gov/buildings/ssl/test_labs.html Report was checked and issued by Mihaly Kotrebai Ph.D. Senior Scientist
Measurements performed by one or more of the following authorized operators: Mike Wise Bob Schall Phil Ellis Yan Chu e-mail: phone: Page 1 of 9
[email protected] 216-266-8958
LM-79 Test Report
112
NVLAP Lab Code: 100398-0
Test Request Number 0980098
Instrumentation Goniometry instrumentation: LSI High Speed Moving Mirror goniophotometer – 25’ Test distance Yokogawa 2010 Digital power meter or equivalent California Instrument Model 4500 AC power source Calibrated mercury thermometer Lambda Gen 1 1500W DC power source Keithley Digital multimeter Calibrated Shunt resistor NIST 300W A-line luminous Flux and Spectral Flux Standard omni-directional source (NIST certificate #: 844/274170-07) Sphere Spectroradiometry instrumentation: OL 770 Spectroradiometer, 50 micron slit, FWHM = 2nm Yokogawa 2010 Digital power meter or equivalent Pacific AT series AC power source or equivalent Calibrated mercury thermometer Sorensen DLM 150-4 DC power source Agilent 34970 Data Acquisition unit Calibrated Shunt resistor 1.5-2 meter sphere with high reflectance coating NIST 300W A-line luminous Flux and Spectral Flux Standard omni-directional source (NIST certificate #: 844/274170-07/2)
Test objective: Goniometric measurement: Measure distribution photometry and input electrical parameters and report candela distribution, calculated lumen output, voltage (V), current (A) and power (W) Sphere spectroradiometric measurement: Measure sphere photometry and input electrical parameters and report the total flux output (lumens), Correlated Color Temperature (CCT), Color Rendering Index (CRI), Chromaticity Coordinates (x,y), Spectral Power Distribution (SPD), voltage (V), current (A) and power (W)
Page 2 of 9
LM-79 Test Report
NVLAP Lab Code: 100398-0 Test Request Number 0980098
Test Procedures and conditions: Goniometry: Electrical conditions and physical orientation were set as required by the lamp manufacturer or the customer Ambient temperature was controlled at 25+/-1 degree Celsius and measured at the approximate height of the sample mounted on the Goniometer equipment Calibration was based on National Institute of Standards and Technology certified total luminous flux standard and maintained by a set of incandescent reflector working standard laps Lamps were stabilized per LM-79 requirements LSI type C High Speed Mirror Goniometer was used to measure intensity (candela) at each angle of distribution Burn time during testing for each lamp: 1.25 Hours Stabilization time during testing for each lamp: 1.25 Hours Sphere Spectroradiometry: Electrical conditions and physical orientation were set as required by the lamp manufacturer or the customer Ambient temperature was controlled at 25+/-1 degree Celsius and measured inside of the sphere, shielded from direct radiation of the lamp Calibration was based on National Institute of Standards and Technology certified total spectral flux standard and maintained by a set of incandescent working standard lamps. Lamps were stabilized per LM-79 requirements Optronic 770 Spectroradiometer attached to a 1.5 or 2 meter sphere painted with high reflectance paint was used to measure correlated color temperature, chromaticity coordinated, color rendering index, total luminous flux, and spectral power distribution. Sphere measurement was set up in 4π geometry and used continuous self-absorption correction. Burn time during testing for each lamp: 1.25 Hours Stabilization time during testing for each lamp: 1.25 Hours Spatial correction factor applied to lamp measurement: 1
Page 3 of 9
LM-79 Test Report
NVLAP Lab Code: 100398-0 Test Request Number 0980098
Sphere Spectroradiometry Test Data: Lamp Lamp Volts Current 12 0.498
Lamp Watts 6.0
Power Factor Lumens 1.00 300.2
LPW CCX CCY u' v' Duv CCT 50.3 0.4336 0.3989 0.2507 0.5188 0.0016 3014
CRI 93.3
Spectral Power Distribution
0.0070 0.0060
Watts/nm
0.0050 0.0040 0.0030 0.0020 0.0010 0.0000 380
420
460
500
540
580
620
660
700
740
780
nm
nm
Watts/nm
nm
Watts/nm
nm
Watts/nm
nm
Watts/nm
nm
Watts/nm
380
0.00002
465
0.00224
550
0.00394
635
0.00593
720
0.00150
385
0.00004
470
0.00181
555
0.00406
640
0.00586
725
0.00128
390
0.00001
475
0.00146
560
0.00419
645
0.00571
730
0.00114
395
0.00001
480
0.00129
565
0.00435
650
0.00548
735
0.00098
400
0.00004
485
0.00127
570
0.00444
655
0.00523
740
0.00083
405
0.00000
490
0.00141
575
0.00458
660
0.00497
745
0.00074
410
0.00003
495
0.00162
580
0.00473
665
0.00468
750
0.00064
415
0.00006
500
0.00190
585
0.00488
670
0.00439
755
0.00054
420
0.00007
505
0.00221
590
0.00502
675
0.00400
760
0.00044
425
0.00015
510
0.00253
595
0.00518
680
0.00369
765
0.00038
430
0.00030
515
0.00279
600
0.00536
685
0.00335
770
0.00035
435
0.00057
520
0.00302
605
0.00551
690
0.00304
775
0.00026
440
0.00104
525
0.00323
610
0.00565
695
0.00273
780
0.00023
445
0.00187
530
0.00341
615
0.00578
700
0.00248
450
0.00319
535
0.00357
620
0.00590
705
0.00216
455
0.00379
540
0.00373
625
0.00597
710
0.00192
460
0.00302
545
0.00384
630
0.00598
715
0.00171
Page 4 of 9
LM-79 Test Report
NVLAP Lab Code: 100398-0 Test Request Number 0980098 CIE 1931 x,y Chromaticity Diagram
0.9
Planckian Locus
0.8
Test lamp
0.7
Illuminant A D65
0.6 0.5
3000 K 5000 K
0.4 10000 K
0.3
2000 K 1000 K
20000 K
0.2 0.1 0.0 -0.1 -0.1
0.0
0.1
0.2
0.3
0.4
Page 5 of 9
0.5
0.6
0.7
0.8
LM-79 Test Report
NVLAP Lab Code: 100398-0 Test Request Number 0980098
Goniometry Test Data: Beam Angle Max 50% of Max 10% of Max
Candela 110.1 55.0 11.0
Half Angle
Full Angle
180.00 124.22 104.03
0.00 111.56 151.94
Volts 12
Amps 0.4990
Watts 5.99
Total Downlight Lumens: Total Uplight Lumens: Total Lumens: Total Lumens/Watt:
Power Factor 1.00 0.60 299.62 300.22
50.1
Polar Plot:
120
180°
165° 150°
96
135°
72
120°
48
105°
24
Average All 0/180 90/270
0
90°
50% Angle
24
75° Candela
48
60°
72
45°
96 120
10% Angle
30° 15°
Page 6 of 9
LM-79 Test Report
NVLAP Lab Code: 100398-0 Test Request Number 0980098 Cartesian Plot: 120.00 100.00
Candela
80.00
Average
60.00 40.00
0/180 AVE
20.00
90/270 AVE
90 99 10 8 11 7 12 6 13 5 14 4 15 3 16 2 17 1 18 0
72 81
54 63
36 45
9 18 27
0
0.00
Angle
Cone Diagram:
Lamp to surface angle
LAMP
0 Degrees
Nominal beam angle degrees =
111.6
LUX at Point
Distance
Circle Diameter (Meters)
445
From lamp
111
0.50 Meters
1.470
49
1.00 Meters
2.941
28
1.50 Meters
4.411
18
2.00 Meters
5.881
12
2.50 Meters
7.351
9
3.00 Meters
8.822
7
3.50 Meters
10.292
5
4.00 Meters
11.762
4
4.50 Meters
13.233
5.00 Meters
14.703
Diameter (Meters) 14.703
Page 7 of 9
LM-79 Test Report
NVLAP Lab Code: 100398-0 Test Request Number 0980098 Candela Distribution
Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180
Average cd 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.8 4.1 13.3 25.2 35.7 46.4 56.6 65.8 74.1 81.6 88.1 93.8 98.6 102.6 105.8 108.0 109.6 110.1
0/180 Average 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 1.0 6.7 15.2 25.6 36.6 47.1 57.1 66.3 74.2 81.5 87.8 94.1 98.8 102.7 105.8 107.9 109.4 110.2
90/270 Average 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.2 0.1 0.2 0.6 1.5 9.3 26.1 36.0 46.2 56.2 65.5 73.8 81.7 88.5 93.7 98.8 102.9 106.1 108.5 109.9 109.3
Zonal Lumens 0.00 0.01 0.01 0.02 0.03 0.04 0.04 0.04 0.04 0.04 0.04 0.03 0.03 0.02 0.02 0.02 0.04 0.06 0.06 0.21 1.12 4.35 10.14 15.39 19.95 23.81 26.64 28.31 28.83 28.36 26.78 24.34 21.11 17.20 12.69 7.78 2.62
Page 8 of 9
Cumulative Lumens 0 0.01 0.02 0.04 0.08 0.11 0.16 0.20 0.24 0.28 0.31 0.35 0.38 0.40 0.42 0.45 0.49 0.55 0.60 0.81 1.93 6.27 16.41 31.80 51.75 75.56 102.21 130.51 159.35 187.70 214.48 238.82 259.94 277.13 289.82 297.60 300.22
% Total 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 1% 2% 5% 11% 17% 25% 34% 43% 53% 63% 71% 80% 87% 92% 97% 99% 100%
LM-79 Test Report
NVLAP Lab Code: 100398-0 Test Request Number 0980098 Individual Lamp Data:
Lamp ID 0980098 - A00120091103 - 141828.spd
Luminous Flux 300.2
Page 9 of 9
Input Voltage Current Power 12.0 0.498 6.0