Technical Data for ADL Power Supplies Seite GS 05 - GS 30
2
GS 60 - GS 150
4
GSW 100 - GSW 300
5
GX 50 - GX 150
9
HX 150 - HX 300
11
GP and GPW-Power Supplies for Melec Pulse Generators
13
ADL-Pulse Generator RD 300
16
Power Supplies for Ion Sources - Accelerator and Beam GG 03, GG03.1, GG12, GG 12.1
17
Power Supplies for Ion Sources - Neutralizer GIP 10 and GIP 10.1
18
Power Supplies for Ion Sources - Discharge GDI
19
Power Supplies for Ion Sources - Cathode GC
20
Power Supplies for Ion Sources - Magnet GM
21
Power Supplies for Plasma Sources - GD
22
D300 Cathode Clamp Diode
23
Maris Remote Control RC 4
24
ADL
ADL Technical Data
Version 09-2009
1
GS 05 - GS 30 Table 1
GS 05/800
GS 10/800
GS 15/800
GS 20/800
GS 30/800
Nominal power
0,5kW
1kW
1,5kW
2kW
3kW
Output voltage
800V
800V
800V
800V
800V
Output current
0,9A
1,7A
3A
3,5A
5,3A
Current, voltage or power controlled
Control
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically 3½- digit display for current, voltage and power
Indications
LpA < 70db (A)
Noise emission Mains connection Power consumption Fusing
230V, +5/-10 %, 50/60Hz, (Option: 200V, L1, L2, PE) 0,6kVA
1,2kVA
1,8kVA
2,4kVA
3,6kVA
6A
6A
6A (10A)
6A (10A)
10A
Forced air, maximum ambiente temperature 40° C
Cooling
½ 19“ slide-in, 3HU (132,5mm), 560mm deep
Size Weight
ADL Technical Data
3 x 400V, +5/-10%, 50/60Hz, (Option: 3 x 200V, only GS 15, GS 20), PE
11kg
12kg
Version 09-2009
2
GS 05/1000
GS 10/1000
GS 15/1000
GS 20/1000
GS 30/1000
GS 12/2000
Nominal power
0,5kW
1kW
1,5kW
2kW
3kW
1,2kW
Output voltage
1000V
1000V
1000V
1000V
1000V
2000V
Output current
0,7A
1,4A
2,4A
2,8A
4,2A
1A
Table 2
Current, voltage or power controlled
Control
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay Time: 6µs up ca. 10ms, automatically 3½- digit display for current, voltage and power
Indications
LpA < 70db (A)
Noise emission Mains connection Power consumption Fusing
230V, +5/-10%, 50/60Hz, (Option: 200V, L1, L2, PE) 0,6kVA
1,2kVA
1,8kVA
2,4kVA
3,6kVA
1,4kVA
6A
6A
6A (10A)
6A (10A)
10A
6A
Forced air, maximum ambiente temperature 40° C
Cooling
½ 19“ slide-in, 3HU (132,5mm), 560mm deep
Size Weight
ADL Technical Data
3 x 400V, +5/-10%, 50/60Hz, (Option: 3 x 200V, nur GS 15, GS 20), PE
11kg
12kg
Version 09-2009
3
GS 60 - GS 150 GS 60/800
GS 80/800
GS 100/800
GS 120/800
GS 150/800
Nominal power
6kW
8kW
10kW
12kW
15kW
Output voltage
800V
800V
800V
800V
800V
Output current
10A
17A
17A
20A
25A
Table 1
Current, voltage or power controlled
Control
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically 3½- digit display for current, voltage and power (Option)
Indications
LpA < 70db (A)
Noise emission
3 x 400V, +5/-10%, 50/60Hz, PE
Mains connection Power consumption Fusing
6,6kVA
9kVA
11kVA
13,2kVA
16,5kVA
16A
16A
20A
25A
25A
Forced air, maximum ambiente temperature 40° C
Cooling
19“ slide-in, 3HU (132,5mm) 570mm deep
Size Weight Mains cable
27kg
29kg
29kg
29kg
31kg
4 x 1,5mm²
4 x 1,5mm²
4 x 2,5mm²
4 x 4mm²
4 x 4mm²
RG 213U or Output cable 3 x 1,5mm²
ADL Technical Data
3 x 2,5mm²
3 x 2,5mm²
Version 09-2009
3 x 2,5mm²
3 x 4mm²
4
GSW 100 - GSW 300 GSW 100/500
GSW 100/800
GSW 150/400
GSW 150/500
GSW 150/600
GSW 150/750
Nominal power
10kW
10kW
15kW
15kW
15kW
15kW
Output voltage
500V
800V
400V
500V
600V
750V
Output current
40A
20A
80A
60A
50A
38A
Table 1
Current, voltage or power controlled
Control
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically 3½- digit display for current, voltage and power (Option)
Indications
LpA < 70db (A)
Noise emission
3 x 400V, +/-10%, 50/60Hz, PE (Option: 3 x 440V oder 3 x 480V)
Mains connection Power consumption
11kVA
11kVA
16,5kVA
16,5kVA
16,5kVA
16,5kVA
Fusing
3 x 20A
3 x 20A
3 x 25A
3 x 25A
3 x 25A
3 x 25A
Water, > 3 L/Min, 2 to 8 Bar, < 40° C Forced air, maximum ambiente temperature 40° C
Cooling
Swagelok B-QC 6 …
Water connection Cooling capability of water
500W
500W
680W
680W
680W
680W
Cooling capability of air
80W
80W
80W
80W
80W
80W
19“ slide-in, 3HU x 700mm deep (without plug)
Size 42kg
42kg
44kg
44kg
44kg
44kg
Mains cable
4 x 2,5mm²
4 x 2,5mm²
4 x 4mm²
4 x 4mm²
4 x 4mm²
4 x 4mm²
Output cable
3 x 10mm²
3 x 2,5mm²
3 x 25mm²
3 x 16mm²
3 x 10mm²
3 x 10mm²
Weight
Mains connection (X2) DC-connection (X1)
ADL Technical Data
Harting Han k4/0 Harting Han 2 MOD
Version 09-2009
5
GSW 150/800
GSW 150/1000
GSW 200/500
GSW 200/750
GSW 200/800
GSW 200/900
Nominal power
15kW
15kW
20kW
20kW
20kW
20kW
Output voltage
800V
1000V
500V
750V
800V
900V
Output current
30A
25A
70A
50A
40A
40A
Table 2
Current, voltage or power controlled
Control
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically 3½- digit display for current, voltage and power (Option)
Indications
LpA < 70db (A)
Noise emission
3 x 400V, +/-10%, 50/60Hz, PE (Option: 3 x 440V oder 3 x 480V)
Mains connection Power consumption
16,5kVA
16,5kVA
22kVA
22kVA
22kVA
22kVA
Fusing
3 x 25A
3 x 25A
3 x 35A
3 x 35A
3 x 35A
3 x 35A
Water, > 3 L/Min, 2 to 8 Bar, < 40° C Forced air, maximum ambiente temperature 40° C
Cooling
Swagelok B-QC 6 …
Water connection Cooling capability of water
680W
680W
950W
900W
900W
900W
Cooling capability of air
80W
80W
150W
100W
100W
100W
19“ slide-in, 3HU x 700mm deep (without plug)
Size Weight
44kg
44kg
49kg
49kg
49kg
49kg
Mains cable
4 x 4mm²
4 x 4mm²
4 x 6mm²
4 x 6mm²
4 x 6mm²
4 x 6mm²
Output cable
3 x 6mm²
3 x 4mm²
3 x 16mm²
3 x 10mm²
3 x 10mm²
3 x 10mm²
Mains connection (X2) DC-connection (X1)
ADL Technical Data
Harting Han k4/0 Harting Han 2 MOD
Version 09-2009
6
GSW 200/1000
GSW 250/750
GSW 250/800
GSW 250/900
GSW 300/500
GSW 300/800
Nominal power
20kW
25kW
25kW
25kW
30kW
30kW
Output voltage
1000V
750V
800V
900V
500V
800V
Output current
35A
60A
50A
50A
70A
60A
Table 3
Current, voltage or power controlled
Control
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically 3½- digit display for current, voltage and power (Option)
Indications
LpA < 70db (A)
Noise emission
3 x 400V, +/-10%, 50/60Hz, PE (Option: 3 x 440V oder 3 x 480V)
Mains connection Power consumption
22kVA
28kVA
28kVA
28kVA
33kVA
33kVA
Fusing
3 x 35A
3 x 50A
3 x 50A
3 x 50A
3 x 63A
3 x 63A
Water, > 3 L/Min, 2 to 8 Bar, < 40° C Forced air, maximum ambiente temperature 40° C
Cooling
Swagelok B-QC 6 …
Water connection Cooling capability of water
900W
1100W
1100W
1100W
1300W
1300W
Cooling capability of air
100W
110W
110W
110W
150W
150W
19“ slide-in, 3HU x 700mm deep (without plug)
Size Weight
49kg
51kg
51kg
51kg
53kg
53kg
Mains cable
4 x 6mm²
4 x 10mm²
4 x 10mm²
4 x 10mm²
4 x 10mm²
4 x 10mm²
Output cable
3 x 6mm²
3 x 16mm²
3 x 10mm²
3 x 10mm²
3 x 16mm²
3 x 16mm²
Mains connection (X2) DC-connection (X1)
ADL Technical Data
Harting Han k4/0 Harting Han 2 MOD
Version 09-2009
7
Table 4
GSW 300/1000
Nominal power
30kW
Output voltage
1000V
Output current
50A Current, voltage or power controlled
Control
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically 3½- digit display for current, voltage and power (Option)
Indications
LpA < 70db (A)
Noise emission
3 x 400V, +/-10%, 50/60Hz, PE (Option: 3 x 440V oder 3 x 480V)
Mains connection Power consumption Fusing
33kVA 3 x 63A Water, > 3 L/Min, 2 to 8 Bar, < 40° C Forced air, maximum ambiente temperature 40° C
Cooling
Swagelok B-QC 6 …
Water connection Cooling capability of water
1300W
Cooling capability of air
150W 19“ slide-in, 3HU x 700mm deep (without plug)
Size Weight
53kg
Mains cable
4 x 10mm²
Output cable
3 x 10mm²
Mains connection (X2) DC-connection (X1)
ADL Technical Data
Harting Han k4/0 Harting Han 2 MOD
Version 09-2009
8
GX 60 - GX 150 GX 50/800
GX 60/800
GX 80/800
GX 80/1000
GX 100/400
GX 100/600
Nominal power
5kW
6kW
8kW
8kW
10kW
10kW
Output voltage
800V
800V
800V
1000V
400V
600V
Output current
14A
15A
20A
16A
38A
30A
Table 1
Current, voltage or power controlled
Control
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically 3½- digit display for current, voltage and power (Option)
Indications
LpA < 70db (A)
Noise emission
3 x 400V, +/-10%, 50/60Hz
Mains connection Power consumption Fusing
6kVA
6,6kVA
9kVA
9kVA
11kVA
11kVA
3 x 16A
3 x 16A
3 x 20A
3 x 20A
3 x 20A
3 x 20A
Water, > 1,5 L/Min, 2 to 8 Bar, < 40° C Forced air, maximum ambiente temperature 40° C
Cooling
Swagelok B-QC 6 …
Water connection Cooling capability of water
300W
Cooling capability of air
45W
300W
400W
400W
500W
500W
45W
50W
50W
50W
50W
½ 19“ slide-in, 3HU (130mm) 520mm deep (without plug), 590mm (with plug).
Size 21kg
21kg
23kg
23kg
23kg
23kg
Mains cable
4 x 1,5mm²
4 x 1,5mm²
4 x 2,5mm²
4 x 2,5mm²
4 x 2,5mm²
4 x 2,5mm²
Output cable
3 x 1,5mm²
3 x 1,5mm²
3 x 2,5mm²
3 x 2,5mm²
3 x 6mm²
3 x 6mm²
Weight
Mains connection (X2)
Harting Han-Modular Compact
DC-connection (X1)
Harting Han-Modular Compact
ADL Technical Data
Version 09-2009
9
GX 100/800
GX 100/1000
GX 120/800
GX 150/800
GX 150/1000
Nominal power
10kW
10kW
12kW
15kW
15kW
Output voltage
800V
1000V
800V
800V
1000V
Output current
25A
20A
30A
38A
30A
Table 2
Current, voltage or power controlled
Control
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically 3½- digit display for current, voltage and power (Option)
Indications
LpA < 70db (A)
Noise emission
3 x 400V, +/-10%, 50/60Hz
Mains connection Power consumption
11kVA
11kVA
13,2kVA
16,5kVA
16,5kVA
Fusing
3 x 20A
3 x 20A
3,25A
3 x 25A
3 x 25A
Water, > 1,5 L/Min, 2 to 8 Bar, < 40° C Forced air, maximum ambiente temperature 40° C
Cooling
Swagelok B-QC 6 …
Water connection Cooling capability of water
500W
500W
600W
750W
750W
Cooling capability of air
50W
50W
60W
60W
60W
½ 19“ slide-in, 3HU (130mm) 520mm deep (without plug), 590mm (with plug).
Size Weight
23kg
23kg
23kg
25kg
25kg
Mains cable
4 x 2,5mm²
4 x 2,5mm²
4 x 4mm²
4 x 4mm²
4 x 4mm²
Output cable
3 x 4mm²
3 x 4mm²
3 x 6mm²
3 x 6mm²
3 x 6mm²
Mains connection (X2)
Harting Han-Modular Compact
DC-connection (X1)
Harting Han-Modular Compact
ADL Technical Data
Version 09-2009
10
HX 150 - HX 300 HX 150/400
HX 150/500
HX 150/600
HX 150/800
HX 150/1000
HX 200/500
Nominal power
15kW
15kW
15kW
15kW
15kW
20kW
Output voltage
400V
500V
600V
800V
1000V
500V
Output current
80A
60A
50A
30A
25A
70A
Table 1
Current, voltage or power controlled
Control
External via A/D interface AS 4, AS 4 F or Profibus
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically 3½- digit display for current, voltage and power (Option)
Indications
LpA < 70db (A)
Noise emission
3 x 400V, +/-10 %, 50/60Hz (Option: 3 x 440V or 3 x 480V)
Mains connection Power consumption
16,5kVA
16,5kVA
16,5kVA
16,5kVA
16,5kVA
22kVA
Fusing
3 x 25A
3 x 25A
3 x 25A
3 x 25A
3 x 25A
3 x 35A
Water, > 3 L/Min, 2 to 8 Bar, < 40° C Forced air, maximum ambiente temperature 40° C SMC KQ2 10mm (Option: Swagelok B QC-6)
Cooling Water connection Cooling capability of water
680W
680W
680W
680W
680W
950W
Cooling capability of air
80W
80W
80W
80W
80W
150W
Width: 218mm, Hight: 222mm, Length (without plug): 645mm
Size Weight
35kg
35kg
35kg
32kg
32kg
37kg
Mains cable
4 x 4mm²
4 x 4mm²
4 x 4mm²
4 x 4 mm²
4 x 4mm²
4 x 6mm²
Output cable
3 x 25mm²
3 x 16mm²
3 x 10mm²
3 x 6mm²
3 x 4mm²
3 x 16mm²
Mains connection (X2) DC-connection (X1)
ADL Technical Data
Harting Han k4/0 Harting Han 2 MOD
Version 09-2009
11
HX 200/800
HX 200/1000
HX 250/800
HX 250/1000
HX 300/800
HX 300/1000
Nominal power
20kW
20kW
25kW
25kW
30kW
30kW
Output voltage
800V
1000V
800V
1000V
800V
1000V
Output current
40A
35A
50A
40A
60A
50A
Table 2
Current, voltage or power controlled
Control
External via A/D interface AS 4, AS 4 F or Profibus
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically 3½- digit display for current, voltage and power (Option)
Indications
LpA < 70db (A)
Noise emission
3 x 400V, +/-10 %, 50/60Hz (Option: 3 x 440V or 3 x 480V)
Mains connection Power consumption
22kVA
22kVA
28kVA
28kVA
33kVA
33kVA
Fusing
3 x 35A
3 x 35A
3 x 50A
3 x 50A
3 x 63A
3 x 63A
Water, > 3 L/Min, 2 to 8 Bar, < 40° C Forced air, maximum ambiente temperature 40° C SMC KQ2 10mm (Option: Swagelok B QC-6)
Cooling Water connection Cooling capability of water
900W
900W
1100W
1100W
1300W
1300W
Cooling capability of air
100W
100W
110W
110W
150W
150W
Width: 218mm, Hight: 222mm, Length (without plug): 645mm
Size Weight
37kg
37kg
39kg
39kg
41kg
41kg
Mains cable
4 x 6mm²
4 x 6mm²
4 x 10mm²
4 x 10mm²
4 x 10mm²
4 x 10mm²
Output cable
3 x 10mm²
3 x 6mm²
3 x 10mm²
3 x 10mm²
3 x 16mm²
3 x 10mm²
Mains connection (X2) DC-connection (X1)
ADL Technical Data
Harting Han k4/0 Harting Han 2 MOD
Version 09-2009
12
Power Supplies for Melec-Pulse Generator GP 10/800
GP 15/800
GP 20/800
GP 30/800
GP 30/1000
Nominal power
1kW
1,5kW
2kW
3kW
3kW
Output voltage
800V
800V
800V
800V
1000V
Output current
1,7A
3A
3,5A
5,3A
4,2A
Table 1
Current, voltage or power controlled
Control
External via A/D interface AS 6
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically 3½- digit display for current, voltage and power
Indications
LpA < 70db (A)
Noise emission
Mains connection
Power consumption Fusing
230V, +5/-10%, 50/60Hz, (Option: 200V, L1, L2, PE) 1,2kVA
1,8kVA
2,4kVA
3,6kVA
3,6kVA
6A
6A (10A)
6A (10A)
10A
10A
Forced air, maximum ambiente temperature 40° C
Cooling
½ 19“ slide-in, 3HU (132,5mm), 560mm deep
Seize Weight
ADL Technical Data
3 x 400V, +5/-10%, 50/60Hz, (Option: 3 x 200V, nur GP 15, GP 20), PE
12kg
11kg
Version 09-2009
13
GP 60/800
GP 100/800
GP 120/800
GP 150/800
Nominal power
6kW
10kW
12kW
15kW
Output current
800V
800V
800V
800V
Output voltage
10A
17A
20A
25A
Table 2
Current, voltage or power controlled
Control
External via A/D interface AS 6
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically
Noise emission
3½- digit display for current, voltage and power 3 x 400V, +/-10%, 50/60Hz, PE
Mains connection Power consumption Fusing
6,6kVA
11kVA
13,2kVA
16,5kVA
16A
20A
25A
25A
Forced air, maximum ambiente temperature 40° C
Cooling
½ 19“ slide-in, 3HU (132,5mm), 560mm deep
Seize Weight Mains cable
27kg
29kg
29kg
31kg
4 x 1,5mm²
4 x 2,5mm²
4 x 4mm²
4 x 4mm²
RG 213U or Output cable 3 x 1,5mm²
ADL Technical Data
3 x 2,5mm²
3 x 2,5mm²
Version 09-2009
3 x 4mm²
14
GPW 150/800
GPW 200/800
GPW 250/800
GPW 300/800
GPW 300/1000
Nominal power
15kW
20kW
25kW
30kW
30kW
Output voltage
800V
800V
800V
800V
1000V
Output current
30A
40A
50A
60A
50A
Table 3
Current, voltage or power controlled
Control
External via A/D interface AS 6
Modes of operation
0 …100 % of nominal current, voltage or power
Set point Output accuracy
+/- 1 % of nominal value for current, voltage or power
Arc suppression
Quenching time: 6µs up to 3ms, automatically Delay time: 6µs up ca. 10ms, automatically
Noise emission
3½- digit display for current, voltage and power 3 x 400V, +/-10%, 50/60Hz
Mains connection Power consumption
16,5kVA
22kVA
28kVA
33kVA
33kVA
Fusing
3 x 25A
3 x 35A
3 x 50A
3 x 63A
3 x 63A
Water, > 3 L/Min, 2 to 8 Bar, < 40° C Forced air, maximum ambiente temperature 40° C
Cooling
Swagelok B-QC 6 …
Water connection Cooling capability of water
680W
900W
1100W
1300W
1300W
Cooling capability of air
80W
100W
110W
150W
150W
19“ slide-in, 3HU x 700mm deep (without plug)
Seize Weight
44kg
49kg
51kg
53kg
53kg
Mains cable
4 x 4mm²
4 x 6mm²
4 x 10mm²
4 x 10mm²
4 x 10mm²
Output cable
3 x 6mm²
3 x 10mm²
3 x 10mm²
3 x 16mm²
3 x 10mm²
Mains connection (X2) DC-Connection (X1)
ADL Technical Data
Harting Han k4/0 Harting Han 2 MOD
Version 09-2009
15
ADL-Pulse Generator RD 300 RD 300
Table 1 Nominal voltage
800V (DC Output voltage of power supply)
Nominal power
30kW (DC Output power of power supply)
Pulse frequency
2kHz, fixed
Pulse on time
480µS bis 490µS
Pulse off time
10µS bis 20µS
Principle of operation
ZVS (Zero Voltage Switch) Resonance converter
Maximum cable length
5m (between Pulse Generator and Cathode)
Indications Auxiliary voltage Cooling Seize
Status LEDs 24V DC +/- 10%, 0,6A Forced air, maximum ambiente temperature 40° C 157mm width, 118mm height, 430mm length 8 kg
Weight Compatible with the following power supplies:
ADL Technical Data
Power supplies of the series GS and GSW with a maximum nominal power of 30kW
Version 09-2009
16
Accelerator and Beam GG 03, GG 03.1, GG 12, GG 12.1 Table 1
GG 03
GG 03.1
GG 12
GG 12.1
Nominal power
300W
30W
1,2kW
200W
Output voltage
Negative, max. 1000V
Output current
300mA
Negative, Positive, max. Positive, max. max. 1000V 2000V 2000V 30mA
100mA
Voltage or current controlled
Control Modes of operation
1A
Manual via frontpanel or external via A/D Interface AS 4 or Profibus
Set point
0 ...100 % of nominal voltage or current
Indications
3 ½ digit displays for voltage and current LpA < 70 db(A)
Noise emission
230V, +5/-10%, 50/60Hz, PE Mains connections 500VA Cooling Seize
100VA
1500VA
Forced air, maximum ambiente temperature 40° C ½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug) 11kg
Weight
ADL Technical Data
250VA
Version 09-2009
17
Neutralizer GIP 10 and GIP 10.1 GIP 10.1 Cathode Emission
Cathode
GIP 10 Discharge
Emission
Nominal power
990W
25W
25W
990W
2,5W
Output voltage
33V
25V
25V
33V
25V
Output current
30A
1A
1A
30A
0,1A
Table 1
Control Modes of operation
Emission or filament current controlled Manual via frontpanel or external via A/D Interface AS 4 or Profibus
Set point
0 ...100 % of nominal emission or filament current
Indications
3 ½ digit displays for emission and filament current
Noise emission Mains connection Cooling Seize
LpA < 70db(A) 230V, +5/-10%, 50/60Hz, PE , 1200VA Forced air, maximum ambiente temperature 40° C ½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug) 11kg
Weight
ADL Technical Data
Version 09-2009
18
Discharge GDI Table 1
GDI 09
Nominal power
900W
Output voltage
150V, floating up to 2kV
Output current
6A
Control Modes of operation
Voltage or current controlled. Manual via frontpanel or external via A/D Interface AS 4 or Profibus
Set point
0 ...100 % of nominal voltage or current
Indications
3 ½ digit displays for voltage and current
Noise emission Mains connection Cooling Seize
LpA < 70db(A) 230V, +5/-10%, 50/60Hz, PE, 1200VA Forced air, maximum ambiente temperature 40° C ½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug) 11kg
Weight
ADL Technical Data
Version 09-2009
19
Cathode GC 10
Table 1 Nominal power
1kW
Output voltage
35V, floating up to 2kV
Output current
30A
Control Modes of operation
Voltage or current controlled Manual via frontpanel or external via A/D Interface AS 4 or Profibus
Set point
0 ...100 % of nominal voltage or current
Indications
3 ½ digit displays for voltage and current
Noise emission Mains connection Cooling Seize
LpA < 70db(A) 230V, +5/-10%, 50/60Hz, PE, 1200VA Forced air, maximum ambiente temperature 40° C ½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug) 11kg
Weight
ADL Technical Data
Version 09-2009
20
Magnet GM 10 Table 1
GM 10
Nominal power
960W
Output voltage
160V, floating
Output current
6A
Control Modes of operation
Voltage or current controlled Manual via frontpanel or external via A/D Interface AS 4 or Profibus
Set point
0 ...100 % of nominal voltage or current
Indications
3 ½ digit displays for voltage and current
Noise emission Mains connection Cooling Seize
LpA < 70db(A) 230V, +5/-10%, 50/60Hz, PE, 1200VA Forced air, maximum ambiente temperature 40° C ½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug) 11kg
Weight
ADL Technical Data
Version 09-2009
21
Plasma Sources GD 20/400
GD 20/600
GD 20/800
GD 30/400
GD 30/600
GD 30/800
Nominal power
2kW
2kW
2kW
3kW
3kW
3kW
Output voltage
400V
600V
800V
400V
600V
800V
Output current
7A
4,5A
3,5A
10A
6,5A
5,3A
Table 1
Control Modes of operation
Voltage or current controlled Manual via front panel or external via A/D interface AS 4 or Profibus
Set point
0 ...100 % of nominal voltage or current
Indications
3 ½ digit displays for voltage and current
Noise emission Mains connection Cooling Seize
LpA < 70 db(A) 3 x 400V, +5/-10%, 50/60Hz, PE (Option: 3 x 200V, only GD 20) Forced air, maximum ambiente temperature 40° C ½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug) 11kg
Weight
ADL Technical Data
Version 09-2009
22
D300 Cathode Clamp Diode D300
HV-Diode, Table 1 Nominal voltage
1000V DC Output voltage of power supply)
Nominal current
70A DC (Output cuurent of power supply)
Forward Voltage
3,5V
Connection
Coaxial cable RG 213 U, PE 3m
Maximum cable length Housing
Aluminum B 125 mm x L 127 m x H 60 mm IP 56
Protection Weight Compatible with the following power supplies:
ADL Technical Data
ca. 0,9 kg (without cable) Power Supplies of the series GS, GSW and GX with a maximum nominal voltage of 30kW
Version 09-2009
23
Remote Control RC 4
Table 1 Interface compatibility Control connection Operation voltage Indication Modes of operation Control Set value setting Seize Weight
ADL Technical Data
AS 3, AS 4, AS 4F (with Adapter)-cable 25-pol. Sub.-D 24V DC, internal voltage suppy via interface 3½-digit LCD, switchable to actual value power, actual value current and actual value voltage, set point, reference voltage Switchable: Operation via remote control or via front panel Switchable: Current, power or voltage control Potentiometer with 10-turn-dial mechanism 280mm x 140mm x 110mm Ca. 0,7kg (without cable)
Version 09-2009
24
ADL Technical Data
Version 09-2009
25
ADL Technical Data
Version 09-2009
26
ADL Technical Data
Version 09-2009
27
ADL Technical Data
Version 09-2009
28
ADL Technical Data
Version 09-2009
29
ADL Technical Data
Version 09-2009
30
ADL Technical Data
Version 09-2009
31
ADL Technical Data
Version 09-2009
32
ADL Technical Data
Version 09-2009
33
ADL Technical Data
Version 09-2009
34
ADL Technical Data
Version 09-2009
35
ADL Technical Data
Version 09-2009
36
ADL Technical Data
Version 09-2009
37
ADL Technical Data
Version 09-2009
38
ADL Technical Data
Version 09-2009
39
ADL Technical Data
Version 09-2009
40
ADL Technical Data
Version 09-2009
41
ADL Technical Data
Version 09-2009
42
ADL Technical Data
Version 09-2009
43
ADL Technical Data
Version 09-2009
44
ADL Technical Data
Version 09-2009
45
ADL Technical Data
Version 09-2009
46
ADL Technical Data
Version 09-2009
47
ADL Technical Data
Version 09-2009
48