Series 30,000 Rotary Process Valve
!@#$
valves & controls
The outstanding performance of triple offset, metal seated Vanessa Series 30,000 valve is the ideal solution to achieve perfect shutoff in any process.
Features • Torque generated elastic metal seal provides zero leakage performance, as from API 598 and API 6D. • Torque-seating action ensures continuous bi-directional, zero leakage performance. • Quarter turn non-rubbing design is achieved by a unique, triple offset geometry, completely eliminating all seat to seal rubbing throughout the valve's 90 degrees rotation. • Stellite® hardfaced standard integral seat results in broader applications, longer valve life and less maintenance. • Single-piece cast body, with face-toface dimensions in accordance to ISO 5752, ANSI B16.10 and API 609 provides interchangeability with gate, high performance butterfly, plug and other valves for simpler and more flexible installation. • All metal construction and sealing and zero leakage performance translate into and inherently firesafe valve. • Long-length hardened bearings, incorporating a standard reinforced, die-formed, flexible graphite bearing protector ensure additional reliability. • Internally and externally retained, three times blowout proof stem is safer to operate and provides complete compliance with API 609. • Integral position indicators on the stem and the top mounting flange ensure positive disc position indication.
A †@çô INTERNATIONAL LTD. COMPANY
Technical data
General application
Design standards : ANSI B16.34 DIN 3840 Flange Drilling : ANSI B16.5, ANSI B16.47 (Series A & B), DIN PN 10-1625-40-64-100-160. Sizes (mm) : 80 to 2100 (3” to 84”) Face-to-face : ISO 5752, ANSI B16.10, API 609. Temperature range : from -254 °C to + 815°C.
The Vanessa valve is successfully installed in the following industries: Oil and Gas Processing, Offshore Platforms, Refineries, Hydrocarbon Storage and Transportation, Liquid Natural Gas (LNG) Storage and Transportation, Chemical and Petrochemical Plants, Power Plants, District Heating, Pulp and Paper, Steel Mills, Sugar Mills. Furthermore, Vanessa has a long-lasting experience of valves installed on services with the following media: Steam (Saturated and Superheated), Geothermal Steam, Hydrocarbons, Hydrogen, Oxygen, Cryogenic Fluids, Hot Gases, Sulphur (Tail Gas), Chemical Solvents, Chlorinated Solvents, Flare Gas.
Tyco reserves the right to change the contents without notice
VANLT-0001-EN-0001
Vanessa Series 30,000 Rotary Process Valve
2a
2c
2b
DISC
2
1a 1c 3a 3b 9a
9b
BRACKET
9
5
1
3
2
8
7
6 SEAL
3
3a
4b
5d
5c
5a
5b
4a
7a
7c
4a
7a
7d
7e
5a
3
5h 5m
PACKING (Optional)
5
A 7
5n
PACKING
5
4c 4d
SHAFT
3
5e
4a
4a
7b
B
7a
6c
SEAL (Optional)
6a
BOTTOM
6
7c
8b
C
THRUST BEARING
Tyco reserves the right to change the contents without notice
6b
8
8a
BUSHING
page 3
Vanessa Series 30,000 Rotary Process Valve
Material selection
Item
Note
Description
Body in Carbon Steel
Body in Stainless Steel
Body Body Seat Disc Retainer Flange Screw Seal Ring Disc Spiral Wound Gasket Shaft Disc Key Pin Pin Retainer Packing Spacer Packing Bushing Stud Nut Stud Bolts Bottom Flange Screw Bottom Spiral Wound Gasket Thrust Bearing Thrust Bearing Washer Key Screw Unloosening Washer Bearing Bracket Screw
ASTM A216 WCB Stellite® gr.21 Weld Overlay ASTM A216 WCB or ASTM A105 ASTM A516 ISO 3506 A4 (AISI 316) UNS S31803 (Duplex) + Graphite AISI 316 + Graphite ASTM A182 F6a AISI 410 AISI 410 AISI 316 Graphite AISI 316 AISI 316 ISO 3506 A2 (AISI 304) ISO 3506 A2 (AISI 304) ASTM A516 ISO 3506 A2 (AISI 304) AISI 316 + Graphite AISI 316 or AISI 410 AISI 316 AISI 316 ISO 3506 A4 (AISI 316) AISI 410 AISI 304 Hard Faced Carbon Steel Alloy Steel
ASTM A351 gr. CF8M Stellite® gr.21 Weld Overlay ASTM A351 gr.CF8M or ASTM A182 Type F316 AISI 316 ISO 3506 A4 (AISI 316) UNS S31803 (Duplex) + Graphite AISI 316 + Graphite ASTM A479 Type XM19 (UNS S20910) UNS S20910 UNS S20910 AISI 316 Graphite AISI 316 AISI 316 ISO 3506 A2 (AISI 304) ISO 3506 A2 (AISI 304) ASTM A240 Type 316 ISO 3506 A2 (AISI 304) AISI 316 + Graphite UNS S20910 AISI 316 AISI 316 ISO 3506 A4 (AISI 316) AISI 316 AISI 316 Hard Faced Carbon Steel Alloy Steel
8b Bearing Protector Bearing and Packing Flushing
Reinforced Graphite
Reinforced Graphite
5h Lantern Ring 5m Plug Live Loaded Packing
AISI 316 AISI 316
AISI 316 AISI 316
5n Seal Ring
Belleville Spring
Alloy Steel
Alloy Steel
Seal Ring
UNS S17400
UNS S20910 or UNS S21800
1a 1b 2a 2b 2c 3a 3b 4a 4b 4c 4d 5a 5b 5c 5d 5e 6a 6b 6c 7a 7b 7c 7d 7e 8a 9a 9b
❑
● ●
●
●
Options (available upon request) Bearing Protector
3a
●
Notes ❑ The selection between cast or forged material depends on valve size. ● Suggested spare parts. 1. The Vanessa Series 30,000 can be manufactured as standard in the following materials: WCB, CF8M, LCB, WC6, CF3M, Nickel Aluminium Bronze, Duplex, 250 SMO. Additionally, the Vanessa Series 30,000 can be manufactured also in the following materials: Monel, Incoloy, Hastelloy, Superduplex, Inconel, Titanium, Alloy 20. 2. Contents may change without notice.
Tyco reserves the right to change the contents without notice
page 2
Vanessa Series 30,000 Rotary Process Valve dimensions and weights
Notes 1. Suggested orientation is with the valve shaft horizontal or inclined from vertical. 2. For service above 200°C (392°F) valve body should be insulated to limit body-totrim differential temperature to 100°C (212°F). 3. All dimensions are in mm and weight is in kilos. 4. Please consult Vanessa for other sizes. 5. Trim A: ∆p max. 10 bar. Trim B: ∆p max. 25 bar. Trim C: ∆p max. 50 bar. Trim D: ∆p max. 110 bar. Trim E: ∆p max. 160 bar.
HIGH PRESSURE SIDE
FACE TO FACE
Double flanged - face to face ISO 5752 table 1 col.13 - body drilling ANSI B16.5 Cl.150 - trim B Size mm
inch
80 100 150 200 250 300 350 400 450 500 600
3 4 6 8 10 12 14 16 18 20 24
Valve Dimensions
Gear Dimensions
A
B
E
L
327 357 397 475 515 592 627 665 700 820 870
125 141 165 214 243 286 312 350 383 407 484
260 290 330 385 425 490 525 545 580 640 690
114 127 140 152 165 178 190 216 222 229 267
FT 24 24 25.5 28.5 30 32 35 36.5 40 43 47.5
Weight
Gear Type
C
I
X
ØV
Valve
M 10 M 10 M 10 OV 50 OV 50 OV 100 OV 100 OV 200 OV 200 MAGA 200-S MAGA 200-C
295 325 365 424 464 539 574 600 635 722 772
52 52 52 67 67 86 86 119 119 80 80
162 162 162 220 220 340 340 370 370 315 315
125 125 125 300 300 500 500 600 600 300 300
22 28 40 61 83 127 166 198 229 308 433
Total
ØV
Valve
Total
767 990 1165 1495 2035 2155 3045 4300 4530 5740
922 1145 1320 1760 2300 2420 3665 4920 5150 6525
27 33 45 72 94 140 179 228 259 350 475
Double flanged - face to face ISO 5752 table 1 col.13 - body drilling ANSI B16.47 series A Cl. 150 - trim B Size mm
inch
700 750 800 900 1000 1050 1200 1350 1400 1500
28 30 32 36 40 42 48 54 56 60
Valve Dimensions A 1049 1118 1143 1305 1315 1357 1652 1765 1820 1892
B 525 615 640 672 741 755 866 985 1050 1132
Gear Dimensions E 794 863 888 1005 1015 1057 1267 1380 1435 1500
L
FT
Gear Type
C
I
292 318 318 330 410 410 470 530 530 600
71.5 75 81 90 90.5 97 108 121 124 132
MAGA 1000-RC MAGA 1000-RC MAGA 1000-RC MAGA 2000-RC MAGA 2000-RC MAGA 2000-RC MAGA 14KR MAGA 14KR MAGA 14KR MAGA 18KR
975 1044 1069 1231 1241 1283 1460 1573 1628 1693
200 200 200 263 263 263 200 200 200 230
Weight X 500 500 500 670 670 670 1055 1055 1055 1200
450 450 450 700 700 700 1400 1400 1400 1400
Double flanged - face to face ISO 5752 table 1 col.13 - body drilling ANSI B16.5 Cl.300 - trim C Size mm
inch
80 100 150 200 250 300 350 400 450 500 600
3 4 6 8 10 12 14 16 18 20 24
Valve Dimensions
Gear Dimensions
A
B
E
L
327 357 440 517 557 610 725 755 870 910 995
125 141 189 236 272 310 335 389 422 461 531
260 290 350 415 455 490 545 575 660 700 785
114 127 140 152 165 178 190 216 222 229 267
FT 28.5 32 36.5 41.5 47.5 51 54 57 60.5 63.5 70
Tyco reserves the right to change the contents without notice
Weight
Gear Type
C
I
X
ØV
Valve
M 10 M 10 OV 50 OV 100 OV 100 OV 200 MAGA 200-S MAGA 200-C MAGA 400-S MAGA 400-S MAGA 400-C
295 325 389 464 504 545 627 657 757 797 882
52 52 67 86 86 119 80 80 100 100 100
162 162 220 340 340 370 315 315 350 350 350
125 125 300 500 500 600 300 300 450 450 450
22 33 61 86 100 175 284 340 487 529 834
page 4
Total 27 38 72 99 113 205 326 382 557 599 904
Vanessa Series 30,000 Rotary Process Valve dimensions and weights
HIGH PRESSURE SIDE
FACE TO FACE
Double flanged - face to face ISO 5752 table 1 col.14 - body drilling ANSI B16.5 Cl.600 - trim D Size mm
inch
80 100 150 200 250 300 350 400 450 500 600
3 4 6 8 10 12 14 16 18 20 24
Valve Dimensions
Gear Dimensions
Weight
A
B
E
L
FT
Gear Type
C
I
X
ØV
Valve
304 388 457 525 665 748 820 935 938 1095 1185
136 185 238 263 328 365 390 438 460 526 623
234 298 355 405 485 538 610 680 683 795 885
180 190 210 230 250 270 290 310 330 350 390
31.5 38 47.5 55.5 63.5 66.5 70 76 82.5 89 101.5
M 10 OV 50-A OV 100-C OV 200-C MAGA 200-C MAGA 400-C MAGA 400-C MAGA 1000-R MAGA 1000-R MAGA 2000-R MAGA 2000-R
266 337 404 460 567 635 707 861 864 1021 1111
60 67 86 119 80 100 100 200 200 263 263
180 220 340 370 315 350 350 500 500 670 670
150 300 500 600 300 450 450 450 450 700 700
30 45 104 120 252 333 476 694 750 1000 1355
Total 35 56 117 150 294 403 546 849 905 1265 1620
Double flanged - face to face ISO 5752 table 1 col.8 - body drilling ANSI B16.5 Cl.900 - trim E Size mm
inch
150 200 250 300 350 400 450 500
6 8 10 12 14 16 18 20
Valve Dimensions
Gear Dimensions
Weight
A
B
E
L
FT
Gear Type
C
I
X
ØV
Valve
457 586 730 988 938 985 1070 1170
238 293 345 480 456 492 510 590
355 466 520 733 683 730 770 870
225 275 325 375 425 475 500 575
55.5 63.5 70 79.5 85.5 89 101.5 108
OV 100-C MAGA 200-C MAGA 400-C MAGA 1000-R MAGA 1000-R MAGA 1000-R MAGA 2000-R MAGA 2000-R
404 521 617 914 864 911 996 1096
86 119 100 200 200 200 263 263
340 370 350 500 500 500 670 670
500 600 450 450 450 450 700 700
167 297 385 588 795 1228 1442 1928
Total 180 327 455 743 950 1383 1707 2193
Notes
1. Suggested orientation is with the valve shaft horizontal or inclined from vertical. 2. For service above 200°C (392°F) valve body should be insulated to limit body-totrim differential temperature to 100°C (212°F). 3. All dimensions are in mm and weight is in kilos. 4. Please consult Vanessa for other sizes. 5. Trim A: ∆p max. 10 bar. Trim B: ∆p max. 25 bar. Trim C: ∆p max. 50 bar. Trim D: ∆p max. 110 bar. Trim E: ∆p max. 160 bar.
Tyco reserves the right to change the contents without notice
page 5
Vanessa Series 30,000 Rotary Process Valve dimensions and weights
HIGH PRESSURE SIDE
FACE TO FACE
Double flanged - face to face ANSI B16.10 table 1 Col. 9 - body drilling ANSI B16.5 Cl. 150 - trim B Size mm inch 80 100 150 200 250 300 350 400 450 500 600
3 4 6 8 10 12 14 16 18 20 24
Valve Dimensions L 203 229 267 292 330 356 381 406 432 457 508
N 124 89 102 105 130 153 175 195 216 228 230
FT 24 24 25.5 28.5 30 32 35 36.5 40 43 47.5
Double flanged - face to face ANSI B16.10 table 2 Col. 11 - body drilling ANSI B16.5 Cl. 300 - trim C
Weight
Size
Valve
Total
mm inch
22 30 43 70 98 139 189 224 272 354 499
27 35 48 81 109 152 202 254 302 396 541
80 100 150 200 250 300 350 400 450
3 4 6 8 10 12 14 16 18
Tyco reserves the right to change the contents without notice
Valve Dimensions L 283 305 404 419 457 502 762 838 914
N 198 95 109 128 140 153 572 618 664
FT 28.5 32 36.5 41.5 47.5 51 54 57 60.5
Weight Valve
Total
28 42 80 124 173 247 312 343 522
33 47 91 137 186 277 354 385 592
page 6
Notes 1. For the dimensions A, B, E, and for Gear Selection and dimensions, please refer to the relevant figures in the previous Double Flanged tables. 2. Suggested orientation is with the valve shaft horizontal or inclined from vertical. 3. For service above 200°C (392°F), valve body should be insulated to limit body-totrim differential temperature to 100°C (212°F). 4. All dimensions are in mm and weight is in kilos. 5. Please consult Vanessa for other sizes. 6. Trim A: ∆p max 10 bar. Trim B: ∆p max 25 bar. Trim C: ∆p max 50 bar. Trim D: ∆p max 110 bar. Trim E: ∆p max 160 bar.
Vanessa Series 30,000 Rotary Process Valve dimensions and weights
HIGH PRESSURE SIDE
FACE TO FACE
Notes 1. For the dimensions A, B, E, and for Gear Selection and dimensions, please refer to the relevant figures in the previous Double Flanged tables. 2 Suggested orientation is with the valve shaft horizontal or inclined from vertical. 3. For service above 200°C (392°F),valve body should be insulated to limit body-totrim differential temperature to 100°C (212°F). 4. All dimensions are in mm and weight is in kilos. 5. Please consult Vanessa for other sizes. 6. Trim A: ∆p max. 10 bar. Trim B: ∆p max. 25 bar. Trim C: ∆p max. 50 bar. Trim D: ∆p max. 110 bar. Trim E: ∆p max. 160 bar.
Lugged - face to face API 609 CL.150 body drilling ANSI B16.5 Cl. 150 - trim B Size
Valve Dimensions
mm inch 80 100 150 200 250 300 350 400 450 500 600
3 4 6 8 10 12 14 16 18 20 24
L
N
48 54 57 64 71 81 92 102 114 127 154
20 24 26 28 32 38 44 49 55 63 78
Weight Valve
Total
13 17 23 36 49 83 117 160 194 270 387
18 22 28 47 60 96 130 190 224 312 429
Lugged - face to face API 609 CL. 300 body drilling ANSI B16.5 CI. 300 - trim C Valve Dimensions
Weight
L
N
Valve
Total
48 54 59 73 83 92 117 133 149 159 181
20 24 26 32 37 39 60 65 63 72 82
18 22 41 56 77 119 254 300 455 499 788
23 27 52 69 90 149 296 342 525 569 858
HIGH PRESSURE SIDE
FACE TO FACE
Wafer- face to face API 609 CL. 150 body drilling ANSI B16.5 CI.150 - trim B Size
Valve Dimensions
mm inch 80 100 150 200 250 300 350 400 450 500 600
3 4 6 8 10 12 14 16 18 20 24
L
N
48 54 57 64 71 81 92 102 114 127 154
20 24 26 28 32 38 44 49 55 63 78
Weight Valve
Total
14 15 20 34 45 73 97 123 164 220 324
19 20 25 45 56 86 110 153 194 262 366
Wafer - face to face API 609 CL. 300 body drilling ANSI B16.5 CI. 300 - trim C Valve Dimensions
Weight
L
N
Valve
Total
48 54 59 73 83 92 117 133 149 159 181
20 24 26 32 37 39 60 65 63 72 82
14 15 29 50 75 109 164 228 285 343 513
19 20 40 63 88 139 206 270 355 413 583
Tyco reserves the right to change the contents without notice
page 7
Vanessa Series 30,000 Rotary Process Valve dimensions, torques and flow data Topworks with bracket - dimensions Not machined
K
= Number of Key
K5 = Key Size (bxhxl)
øD = Bolt Circle Diameter N
= Number of Holes
F
= Holes Size
ISO = ISO 5211 Reference
Trim B
Notes
Size
Shaft Dimension
mm
inch
ØE
80 100 150 200 250 300 350 400 450 500 600
3 4 6 8 10 12 14 16 18 20 24
18 18 28 28 28 35 35 45 45 50 55
Coupling Flange Dimension
H
K
KS (bxhxl)
ISO
A
C
S
ØD
N
F
ØL
36 36 40 40 40 56 56 80 80 80 140
1 1 2 2 2 2 2 2 2 2 2
6x6x36 6x6x36 8x7x40 8x7x40 8x7x40 10x8x56 10x8x56 14x9x80 14x9x80 14x9x80 16x10x140
F10 F10 F14 F14 F14 F16 F16 F16 F16 F25 F25
120 120 175 175 175 200 200 200 200 300 300
140 140 175 175 175 240 250 250 260 340 340
6 6 8 8 8 10 12 12 15 15 15
102 102 140 140 140 165 165 165 165 254 254
4 4 4 4 4 4 4 4 4 8 8
12 12 18 18 18 22 22 22 22 18 18
72 72 103 103 103 133 133 133 133 204 204
Trim C Size
Shaft Dimension
mm
inch
ØE
80 100 150 200 250 300 350 400 450 500 600
3 4 6 8 10 12 14 16 18 20 24
18 18 28 35 35 45 50 55 65 65 75
Coupling Flange Dimension
H
K
KS (bxhxl)
ISO
A
C
S
ØD
N
F
ØL
36 36 40 56 56 80 80 140 140 140 160
1 1 2 2 2 2 2 2 2 2 2
6x6x36 6x6x36 8x7x40 10x8x56 10x8x56 14x9x80 14x9x80 16x10x140 18x11x140 18x11x140 20x12x160
F10 F10 F14 F16 F16 F16 F25 F25 F30 F30 F30
120 120 175 200 200 200 300 300 350 350 350
140 140 175 240 250 260 340 340 400 400 410
6 6 8 10 12 15 15 15 20 20 20
102 102 140 165 165 165 254 254 298 298 298
4 4 4 4 4 4 8 8 8 8 8
12 12 18 22 22 22 18 18 22 22 22
72 72 103 133 133 133 204 204 234 234 234
Trim D Size
Shaft Dimension
mm
inch
80 100 150 200 250 300 350 400 450 500 600
3 4 6 8 10 12 14 16 18 20 24
ØE 20 30 40 45 55 60 70 75 90 100 120
Coupling Flange Dimension
H
K
KS (bxhxl)
ISO
A
C
S
ØD
N
F
ØL
40 40 65 80 110 140 140 160 160 200 220
1 2 2 2 2 2 2 2 2 2 2
6x6x40 8x7x40 12x8x63 14x9x80 16x10x110 18x11x140 20x12x140 20x12x160 25x14x160 28x16x200 32x18x220
F10 F14 F16 F16 F25 F30 F30 F35 F35 F40 F40
120 160 160 160 300 350 350 415 415 475 475
180 250 260 270 330 380 400 470 470 580 580
10 10 10 15 15 18 20 20 20 30 30
102 140 165 165 254 298 298 356 356 406 406
4 4 4 4 8 8 8 8 8 8 8
12 18 22 22 18 22 22 32 32 39 39
77 105 132 135 203 234 234 265 265 305 305
Tyco reserves the right to change the contents without notice
page 8
1. Directional arrow represents the direction of the higher pressure side of the valve. 2. The rectangular shaft keys are according to ISO 773 and are shown with valve in closed position. 3. When only one key is foreseen, please consider the one indicated with (*) in the drawing. 4. It is possible to assemble the bracket rotated of 90° in respect of the above configuration. 5. All dimensions are in mm. 6. Trim A: ∆p max. 10 bar. Trim B: ∆p max. 25 bar. Trim C: ∆p max. 50 bar. Trim D: ∆p max. 110 bar. Trim E: ∆p max. 160 bar.
Vanessa Series 30,000 Rotary Process Valve dimensions, torques and flow data
Flow data Rated CV - KV - ζ Shaft side
Trim A
DN
ND
(mm)
(in)
Cv
Kv
75 100 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 1050 1200
3 4 6 8 10 12 14 16 18 20 24 28 30 32 36 40 42 48
29570 34470 40060 52130 64500 71440 96130
25327 29524 34311 44649 55244 61188 82335
Trim B ζ 0,59 0,57 0,55 0,52 0,51 0,51 0,48
Cv 94 210 790 1530 2589 3923 5195 6940 9116 11590 17590 28000 31500 36000 45000 56000 61700 81000
Kv 81 180 677 1310 2217 3360 4450 5944 7808 9927 15066 23982 26980 30834 38543 47964 52846 69377
Trim C ζ 7,65 4,85 1,73 1,46 1,25 1,12 1,19 1,14 1,05 0,99 0,90 0,65 0,68 0,68 0,69 0,68 0,68 0,68
Cv
Kv
94 210 630 1250 2383 3579 4627 6251 8237 10440 16180 23400 30000 33300 42500 51800 53350 73970
81 180 540 1071 2041 3065 3963 5354 7055 8942 13858 20042 25695 28521 36401 44367 45694 63355
Trim D ζ 7,65 4,85 2,73 2,19 1,47 1,35 1,50 1,40 1,29 1,23 1,06 0,94 0,75 0,79 0,78 0,80 0,91 0,81
Cv
Kv
150 250 600 1080 1700 2520 4068 5380 7470 9820 14940 23850 32650 -
128 214 514 925 1456 2158 3484 4608 6398 8411 12796 20428 27965 -
Trim E ζ 3,01 3,42 3,01 2,93 2,89 2,73 1,94 1,89 1,57 1,39 1,24 1,19 1,32 -
Cv
Kv
500 930 1450 2150 3140 4358 5670 7499 10400 -
428 797 1242 1841 2689 3733 4856 6423 8908 -
ζ 4,33 3,95 3,97 3,75 3,25 2,88 2,73 2,38 2,56 -
Percent of rated Cv
Cv curve
Percent of rated travel
FL-XT-XF values Opening angle (°) 10 20 30 40 50 60 70 80 90
Cv value calculation FL
XT
0.85 0.84 0.82 0.79 0.75 0.70 0.65 0.58 0.60
0.53 0.52 0.50 0.48 0.44 0.40 0.36 0.32 0.28
XFz 0.58 0.56 0.54 0.50 0.45 0.39 0.34 0.26 0.29
Notes 1. Flow direction from shaft side (fluid flow helps closing operation). 2. Rated Cv: Cv value at max. position angle. 3. ζ = flow resistance coefficient. 4. FL: pressure recovery factor for liquid. 5. XT: differential pressure ratio for gas. 6. XFz: characteristic pressure ratio according to IEC 534-8-3. 7. Trim A: ∆p max. 10 bar. Trim B: ∆p max. 25 bar. Trim C: ∆p max. 50 bar. Trim D: ∆p max. 110 bar. Trim E: ∆p max. 160 bar. 8. The values in the graph are typical and may vary depending on size and trim.
The following factors have to be considered when performing a Cv value calculation: flow value, characteristic, choked and critical flow, and regulation ratio. Cv or Kv flow value Kv is the flow of water at 15°C in m3/h and at a pressure drop of 1 bar at constant conditions within the valve. Cv is the flow of water in gpm at 60°F and at a pressure drop of 1 psi at constant conditions within the valve. Cv: 1.1675 Kv Characteristic according to IEC 534-2/ISA S75.01 and S75.02. Cv/Rated Cv values The flow characteristic represents the flow in relation to the opening position of the valve at constant pressure drop. Choked and critical flow The choked and critical flow is the max. possible flow of compressible and incompressible media through the valve at operating conditions. Regulation ratio Cv min/Rated Cv The regulation ratio is the ratio of max. and min. flow (Cv or Kv) adjustable without any practical variation. A calculation program according to IEC 534 is available to calculate the Cv value. The characteristic values and the Cv values may differ slightly depending on the flow direction. This will be allowed for in the calculation program. The noise level is calculated according to VDMA 24422 (liquid) and IEC 534-8-3 (gas).
Tyco reserves the right to change the contents without notice
page 9
Vanessa Series 30,000 Rotary Process Valve dimensions, torques and flow data
Torque data Trim B
Trim C Operating Differential Pressure 6.25 bar 12.5 bar 25 bar
DN
DN
RUNNING Flow
(mm)
(in)
(Nm)
direction
80
3
41
100
4
51
150
6
51
200
8
100
250
10
153
300
12
209
350
14
273
400
16
345
450
18
426
500
20
426
600
24
614
650
26
765
700
28
1.393
750
30
1.726
800
32
1.726
900
36
2.099
1000
40
2.981
1050
42
2.981
1200
48
5.433
Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional
end to
start to
end to
start to
end to
start to
CLOSE
OPEN
CLOSE
OPEN
CLOSE
OPEN
(Nm)
(Nm)
(Nm)
(Nm)
(Nm)
(Nm)
79 79 108 108 187 187 256 256 475 475 676 676 818 818 1.078 1.078 1.371 1.371 1.490 1.490 2.162 2.162 3.754 3.754 5.458 5.458 6.259 6.738 7.219 7.231 10.632 10.632 13.159 13.159 14.611 15.469 22.853 22.853
79 95 108 129 187 224 256 308 475 570 676 811 818 981 1.078 1.293 1.371 1.645 1.490 1.787 2.162 2.594 3.754 4.505 5.458 6.550 6.975 8.085 7.372 8.677 10.632 12.759 13.159 15.791 15.499 18.563 22.853 27.423
79 79 108 108 187 187 256 256 475 475 676 676 818 860 1.078 1.179 1.371 1.559 1.490 1.830 2.162 3.007 3.754 5.756 5.458 9.938 6.259 13.476 7.219 14.462 10.632 19.761 13.159 24.231 14.611 30.938 22.853 38.533
79 95 108 129 187 224 256 308 475 570 676 811 832 1.032 1.136 1.415 1.498 1.871 1.745 2.196 2.881 3.608 5.387 6.907 9.543 11.926 13.087 16.171 13.882 17.355 18.684 23.714 23.090 29.077 29.507 37.126 36.679 46.240
79 100 108 149 187 285 256 475 475 864 676 1.288 818 1.719 1.078 2.358 1.371 3.119 1.490 3.659 2.162 6.014 3.754 11.512 5.458 19.876 6.259 26.951 7.219 28.925 10.632 39.523 13.159 48.462 14.611 61.877 22.853 77.066
89 120 132 179 236 343 423 570 750 1.036 1.122 1.546 1.529 2.063 2.099 2.829 2.783 3.742 3.277 4.391 5.456 7.217 10.392 13.814 18.389 23.852 25.311 32.341 26.900 34.710 36.319 47.427 44.689 58.154 57.523 74.252 70.641 92.479
Operating Differential Pressure 12,5 bar 25 bar 50 bar RUNNING Flow (Nm)
direction
64 79 154 321 420 531 656 944 1.108 1.285 1.679
3.279 3.864 4.609 6.315 8.375 11.373
end to
start to
end to
start to
end to
start to
CLOSE
OPEN
CLOSE
OPEN
CLOSE
OPEN
(Nm)
(Nm)
(Nm)
(Nm)
(Nm)
(Nm)
Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional
134 134
134 161
134 134
134 161
134 176
154 212
188 188 358 358 525 525 969 969 1.371 1.371 1.655 1.655 2.186 2.186 2.770 2.770 2.999 2.999 4.324 4.324
188 226 358 429 525 630 969 1.163 1.371 1.646 1.655 1.986 2.186 2.623 2.770 3.324 2.999 3.599 4.324 5.189
188 188 358 358 525 551 969 969 1.371 1.410 1.655 1.809 2.186 3.008 2.770 3.480 2.999 4.442 4.324 6.855
188 226 358 429 607 661 969 1.163 1.401 1.692 1.806 2.170 3.043 3.609 3.480 4.175 4.485 5.330 6.830 8.227
188 272 358 599 525 1.102 969 1.901 1.371 2.820 1.655 3.617 2.186 6.016 2.770 6.959 2.999 8.884 4.324 13.711
236 326 533 719 1.053 1.323 1.724 2.282 2.537 3.384 3.283 4.341 5.613 7.219 6.405 8.351 8.327 10.661 12.821 16.453
Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional
8.076 8.076 14.910 14.910 14.910 14.910 24.726 24.726 30.554 30.554 29.396 33.060
8.076 9.691 14.910 17.892 14.910 17.892 24.726 29.671 30.554 36.664 35.807 39.672
8.076 12.739 14.910 23.468 14.910 24.176 24.726 38.236 30.554 44.160 29.396 66.120
12.764 15.287 22.418 28.162 23.498 29.011 36.449 45.883 42.237 52.992 65.927 79.344
8.076 25.479 14.910 46.936 14.910 48.352 24.726 76.472 30.554 88.321 29.396 132.240
23.888 30.575 42.904 56.323 44.692 58.022 69.739 91.766 80.287 105.985 126.168 158.688
Torque data Trim D
Trim A
Operating Differential Pressure 27,5 bar 55 bar 110 bar
Operating Differential Pressure 2,5 bar 5 bar 10 bar DN
DN
RUNNING Flow
(mm)
(in)
(Nm)
direction
700
28
608
750
30
765
800
32
765
900
36
765
1000
40
1.393
1050
42
1.393
1200
48
1.726
Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional
end to
start to
end to
start to
end to
start to
CLOSE
OPEN
CLOSE
OPEN
CLOSE
OPEN
(Nm)
(Nm)
(Nm)
(Nm)
(Nm)
(Nm)
1.872 1.872 2.146 2.475 2.476 2.636 4.051 4.051 5.014 5.014 5.567 5.766 7.465 7.465
1.942 2.247 2.643 2.970 2.771 3.163 4.051 4.862 5.014 6.016 5.906 6.920 7.465 8.958
1.872 3.650 2.146 4.950 2.476 5.272 4.051 7.182 5.014 8.932 5.567 11.533 7.465 13.331
3.579 4.380 4.903 5.940 5.159 6.327 6.754 8.618 8.626 10.719 11.116 13.839 12.701 15.998
1.872 7.300 2.146 9.900 2.476 10.544 4.051 14.363 5.014 17.864 5.567 23.066 7.465 26.663
6.855 8.760 9.424 11.879 9.936 12.653 13.125 17.236 16.555 21.437 21.535 27.679 24.539 31.995
end to start to end to start to end to start to DN DN RUNNING Flow (mm) (in)
(Nm)
80
3
59
100
4
196
150
6
353
200
8
608
250
10
745
300
12 1.079
350
14 1.337
400
16 1.687
450
18 4.550
500
20 5.609
600
24 9.434
700
28 9.358
750
30 12.847
Notes Trim A: ∆p max 10 bar. Trim B: ∆p max 25 bar. Trim C: ∆p max 50 bar. Trim D: ∆p max 110 bar. Trim E: ∆p max 160 bar.
Tyco reserves the right to change the contents without notice
page 10
direction Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional Shaft Side Bidirectional
CLOSE (Nm) 214 214 382 382 700 700 1.666 1.666 2.678 2.678 3.469 3.469 4.528 4.528 4.988 4.988 7.924 7.924 10.560 10.560 11.164 11.164 19.986 20.344 29.676 29.676
OPEN CLOSE OPEN (Nm) 214 256 382 458 700 840 1.666 1.999 2.678 3.214 3.469 4.163 4.528 5.433 4.988 5.986 7.924 9.509 10.560 12.672 14.420 14.420 23.024 24.412 29.676 35.611
(Nm) 214 214 382 387 700 898 1.666 1.723 2.678 2.996 3.469 4.280 4.528 5.178 4.988 7.278 7.924 12.538 10.560 16.349 11.164 21.638 19.986 40.687 29.676 51.973
(Nm)
CLOSE OPEN (Nm)
(Nm)
214 214 324 256 380 456 409 382 719 464 774 929 934 700 1.691 1.077 1.795 2.154 1.694 1.666 3.084 2.068 3.447 4.136 2.833 2.678 5.293 3.595 5.991 7.190 4.125 3.469 7.711 5.136 8.559 10.271 4.941 4.528 9.214 6.214 10.356 12.428 7.124 4.988 13.405 8.734 14.556 17.468 13.228 7.924 24.182 15.046 25.076 30.091 17.042 10.560 31.279 19.619 32.699 39.238 24.122 11.164 43.527 25.966 43.276 51.931 41.369 19.986 78.059 48.825 81.375 97.650 52.461 29.676 98.500 62.368 103.947 124.736
Vanessa Series 30,000 Rotary Process Valve dimensions, torques and flow data
Maximum allowable torque Trim B
Trim C
Trim A
Body Material Max allowable
DN
temperature
(mm)
(in)
(Nm)
80
3
100
4
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
650
26
700
28
750
30
800
32
900
36
1000
40
1050
42
1200
48
to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to
CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN
Body Material
Max allowable
torque at ambient DN
Body Material Max allowable
torque at ambient A 216 WCB
A351 gr.CF8M
torque at ambient
temperature
A 216 WCB
A351 gr.CF8M
(Nm) 330 495 357 666 357 615 1086 1708 1234 2000 1930 3147 2627 4767 4151 6737 5582 9185 5197 8744 8949 15077 18697 30667 34554 55237 44659 76788 44659 74912 60793 98557 78131 127158 75334 124362 119844 197698
315 434 315 582 315 531 1146 1477 1184 1715 2048 2695 2312 4093 4402 5776 4914 7867 5541 7427 8973 12801 19857 26221 36557 47555 39315 66251 39315 64374 64452 84532 82881 108950 80084 106153 127386 168783
to to to to to to to to to to to to to to to to to to to to to to
CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN
311 476 357 628 1061 1684 1997 3214 2627 4632 3825 6410 5412 8959 9464 15593 11654 19446 14135 23867 20044 34570
315 415 315 544 1122 1453 2115 2762 2312 3957 4075 5450 5756 7642 8973 13316 12409 16552 14811 20252 21451 29175
to to to to to to to to to to to to
CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN
41367 69740 54643 92407 54643 92407 87129 149464 105424 183278 202783 342177
44116 59202 58302 78382 58302 78382 93168 126313 112967 154363 216288 290407
Maximum allowable torque
DN
DN
temperature
(mm)
(in)
(Nm)
700
28
750
30
800
32
900
36
1000
40
1050
42
1100
44
1150
46
1200
48
to to to to to to to to to to to to to to to to to to
A 216 WCB
A351 gr.CF8M
17686 27418 21799 33769 21237 33206 20094 32064 36010 56694 35171 55855 35171 55855 35171 55855 44659 75507
CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN
18498 23803 22752 29324 22396 28761 21254 27618 38014 49012 37175 48173 37175 48173 37175 48173 39315 64969
1,0
§Trim D Max allowable torque at ambient DN
DN
(mm)
(in)
80
3
100
4
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
750
30
temperature
A 216 WCB
A351 gr.CF8M
(Nm) to to to to to to to to to to to to to to to to to to to to to to to to to to
CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN
247 412 1057 1680 1822 3039 3897 6482 6985 11706 8276 14404 13276 23007 15586 27555 28672 49355 39407 67779 68553 117580 110600 188454 100864 178718
263 351 1118 1449 1940 2587 4147 5522 7443 9953 8870 12128 14218 19393 16745 23110 30676 41673 42156 57242 73303 99372 118143 159539 108407 149803
Ratio between max. allowable Torque and Max. allowable Torque at ambient temperature
A216 WCB
Body Material
0,9
A351 gr.CF8M
0,8
0,7
0,6
0,5
0,4 0
100
200
300
400
500
600
700
Temperature (°C)
Notes 1. Unidirectional – Bi-directional installation. Shaft side installation is the preferred direction as the fluid pressure helps seat the seal ring. Disc side installation requires a higher end to close torque, as the fluid action is opposite. 2. End to close – Start to open torques. End to close is the torque required at 0° disc position angle to properly seat the seal ring and to reach the desired tightness performances. All safety factors are already included in the published torque values both for test and for operating conditions. Start to open is the torque required at 0° disc position angle to properly unseat the seal ring. Within the first degrees of disc movement the seal ring is totally unseated and the torque values drastically lower during the rest of the travel. 3. Running torque and Dynamic torque. Running torque is the torque required to operate the valve from 0° to 90° degrees of opening (and closing). Dynamic torque shows its effects with high fluid pipe velocities. Only above 3 m/s (10 ft/s) for liquid medium and 50 m/s (164 ft/s) for gaseous medium dynamic torque cannot be neglected. Tyco reserves the right to change the contents without notice
page 11
Vanessa Series 30,000 Rotary Process Valve
Pressure/temperature ratings in barg/psig (ANSI B16.34)
Notes
PRESSURE
All Vanessa valves are rated fully in accordance with ANSI B16.34. The table here represented indicates the pressure/temperature rating values as per ANSI B16.34, 1996.
TEMPERATURE
Weight comparison - ANSI class 150
Gate Valve Ball Valve
WEIGHT (in kilos)
Vanessa Series 30,000 - Double Flanged Configuration
SIZE (in inches)
Weight comparison - ANSI class 300
Gate Valve Ball Valve
WEIGHT (in kilos)
Vanessa Series 30,000 - Double Flanged Configuration
SIZE (in inches) Tyco reserves the right to change the contents without notice
page 12