TIA Portal V11 – Exercises - infoPLC - Robotica

SIMATIC Systems Support I IA AS CS 2 FA TIA Portal V11 Seite / page 3 Task: Start TIA Portal and create a new project What to do: 1. Select the option...

7 downloads 383 Views 6MB Size
TIA Portal V11 – Exercises Micro Automation

For internal use only / © Siemens AG 2010. All Rights Reserved.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 1

TIA Portal V11 – Exercises

ƒ Basics: PLC exercise ƒ Basics: HMI exercise ƒ Exercise: Hardware Configuration ƒ IECPL-Exercise: Programming

For internal use only / © Siemens AG 2010. All Rights Reserved.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 2

Exercise: First program with TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Page 3

Task:

1

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Start TIA Portal and create a new project

What to do: 1. Select the option “Create new project” and name it “my_first_project”. Create the project with the button “Create”.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 3

Exercise: First program with TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

2

Page 4

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Create a new program.

What to do: 2. Under “First steps” choose the option “Write a PLC program” -> You now have to specify a PLC. Select a S7-317PN/DP (E.g.: 6ES7317-2EK13-0AB0). The block “Main” is the shown. 3. With double-click on the program block “Main”, the program block editor on the project view is opened. The program block “Main” is directly opened.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 4

Exercise: First program with TIA Portal Hands-on Basics: PLC exercise

4

Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Page 5

6

Exercises for TIA Portal V11 (Micro Automation)

Task:

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Programming in the program block “Main”.

What to do: 4. Create a program in network 1, like the one shown above. The instructions from the favorite list, like contacts for example, can be used in the program via Drag & Drop or double click Provide the symbolic names to the instructions: “START_1“, “STOP“ and “Drive_1“. 5. Save your project 6. Select the network. Using the “Define Option” on the context menu an address to each variable in the network can be defined. 7. Change the zoom in your network to 120% using the zoom function.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 5

Exercise: First program with TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

7

8

Page 6

Task:

Exercises for TIA Portal V11 (Micro Automation)

7

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Defining a variable in the variable table

What to do: 8. On the project tree, open the “Default tag table” from the “PLC_tags”. Using the auto fill function, add the variables “START_2” to “START_8.” The tags should be added, not overwritten.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 6

Exercise: First program with TIA Portal Hands-on

9

Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

13

12

Page 7

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Copy network 1 to network 2 using Drag & Drop

What to do: 9. Select the code in network 1 using the lasso-function. 10. Copy the code using the context menu 11. Select the circuit ( the horizontal line) in network 2 and paste the copied network. 12. In network 2, rename “START_1” to “START_2”. 13. In network 2, rename “Drive_1” to “Drive_2”. 14. Save your project.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 7

Exercise: First program with TIA Portal Hands-on Basics: PLC exercise

17

Basics: HMI exercise Exercise: Hardware Configuration

16 15

IECPL-Exercise: Programming

Page 8

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Add elements to favorite list in TIA Portal

What to do: 15. Select the Block title and change the programming language from LAD to FBD in the properties of the inspector window. 16. Using Drag & Drop, add an “On-Delay Timer” from the task card “Simple instructions” to the favorite list. 17. Close the task menu “Instructions” using the button “Collapse automatically”. Note: the task cards is then normally minimized and is shown when the user click on it. 18. Add an On-Delay timer in network 2, so that Drive_2 is activated 2 seconds after the request. 19. Confirm the menu pressing “OK”. An Instance DB is automatically created.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 8

Exercise: First program with TIA Portal Hands-on

23 Basics: PLC exercise

22

25

Basics: HMI exercise

21

Exercise: Hardware Configuration

20

IECPL-Exercise: Programming

24

Page 9

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Assign an absolute address to „Drive_2“ using Drag & Drop.

What to do: 20. Open the “Device view” with a double click in “Device configuration” 21. Add an DI8/DO8 module from the hardware catalogue. e.g.: 6ES7 323-1BH01-0AA0 22. Change the zoom to 300% 23. Divide the working area, as seen in the figure. 24. Assign the absolute output address Q 0.2 to “Drive_2” via Drag & Drop. 25. Close the block “Main”.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 9

Exercise: First program with TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise

26

Exercise: Hardware Configuration

27

IECPL-Exercise: Programming

28

Page 10

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Configure a PROFINET network

What to do: 26. Change the view to “Network view” 27. From the hardware catalog, add an ET200S-Profinet station. e.g.: 6ES7 151-3BA230AB0 It can be found on “Distributed I/O” Æ ”ET200S” Æ ”Headmodule” Æ”PROFINET”. 28. Link the ET200S station with the PLC. Result:

The PROFINET connection and the related PN protocol are configured with a single mouse click.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 10

Exercise: First program with TIA Portal Hands-on Basics: PLC exercise

29

Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

30

Page 11

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Establishing a hardware configuration

What to do: 29. Change the view to “Device view” 30. From the hardware catalog, add one power module (e.g.: 6ES7 138-4CA01-0AA0), one digital input module (e.g.: 6ES7 138-4BD01-0AA0), and one digital output module (e.g.: 6ES7 132-4BD32-0AA0)

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 11

Exercise: First program with TIA Portal Hands-on

32

Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

31 33

Page 12

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Start the simulation

What to do: 31. Select the PLC on the project navigation. 32. Start the simulation. 33. Add the output byte QB0 in the simulation Note: The components that are downloaded in the PLC when a simulation is started can be configured in “Options” Æ ”Settings”.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 12

Exercise: First program with TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise

34

Exercise: Hardware Configuration

Note: Choose for the actual increment of the software: MPI for the connection with PLCSIM

IECPL-Exercise: Programming

Page 13

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Download in PLCSIM

What to do: 34. After the start of the simulation the dialogue “Extended Loading” is opened automatically. Select the interface to PLCSIM and load your configuration into the PLC.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 13

Exercise: First program with TIA Portal Hands-on

36

Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration

35

IECPL-Exercise: Programming

Page 14

37

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: 35. Select the Program container in the project navigation. 36. By using the button “Load” your program could be loaded to PLCSIM. Note: this task is only necessary when the program is not loaded to the PLC with starting PLCSIM. This behavior is depending on your settings for the simulation. 37. In the Load preview you can select how the blocks should be loaded to the PLC. Select “Load all” or “Consistent download” and load your program to the PLC. 38. Close the dialogue. 39. Start your PLC in PLCSIM (select RUN-P)

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 14

Exercise: First program with TIA Portal Hands-on

41

42

Page 15

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Monitoring a program

What to do: 40. Open the program block “Main” 41. Press the button “Monitoring on/off” to monitor the actual state of the block in the editor. 42. Activate the memory tag “START_1” using the context menu “Modify” Æ ”Modify to 1”.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 15

Exercise: First program with TIA Portal Hands-on

44

45

43

Page 16

Exercises for TIA Portal V11 (Micro Automation)

Task:

47

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Adding a variable

What to do: 43. Create a new watch table using “Add new watch table” in the project tree. 44. Detach the watch table window using the button “Float”. 45. Using the lasso function, select the elements in network 1 and using Drag & Drop inserts them in the watch table. 46. The values for “START_1” and “STOP” can be given in the column “Modify value”. These values are sent to the controller using the “Modify the selected values once and now”. 47. Go “offline”.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 16

TIA Portal V11 – Exercises

ƒ Basics: PLC exercise ƒ Basics: HMI exercise ƒ Exercise: Hardware Configuration ƒ IECPL-Exercise: Programming

For internal use only / © Siemens AG 2010. All Rights Reserved.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 17

Exercise: First HMI project in TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

1

3 2

4

Page 18

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Configuring a new panel

What to do: 1. In the portal view, on the “Device and network” menu, select “Add new device”. 2. Select HMI as device to be added. 3. Select the TP700 Comfort panel 4. Start the “Device wizard”.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 18

Exercise: First HMI project in TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

5

Page 19

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: 5. Establish a connection to the controller.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 19

Exercise: First HMI project in TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

6

Page 20

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: 6. Activate the “Page header” for the panel.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 20

Exercise: First HMI project in TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Page 21

7

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: 7. Configure the alarms as shown in the slide.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 21

Exercise: First HMI project in TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

6

Page 22

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: 8. Define the screen navigation as shown in the slide. Name the screens as shown (i.e.: Drives, PID and Communication).

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 22

Exercise: First HMI project in TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

9

Page 23

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: 9. Activate the system screens.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 23

Exercise: First HMI project in TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

10

11

Page 24

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: 10. Arrange the system buttons as seen in the slide. 11. Close the wizard pressing “Finish”.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 24

Exercise: First HMI project in TIA Portal Hands-on

15 13 12

14

Page 25

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Showing the state of “Drive_1”.

What to do: 12. Open the screen “Drives” with a double click. 13. Select the “PLC tags” Æ ”Default tag table” in the project tree. All variables are now shown in the detail view. 14. Drag the variable “Drive_1” to the screen “Drives”. 15. Insert a text field and write in it: “Drive_1”

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 25

Exercise: First HMI project in TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

16

Page 26

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Adding a button to start the output “Drive_1”.

What to do: 16. Add a button from the “Toolbox”. Give it the label “START_1”.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 26

Exercise: First HMI project in TIA Portal Hands-on

19 18

17 20

21

Page 27

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: 17. Select the button “START_1“. 18. Open the task card “Properties” in the inspector window. 19. Select the task card “Events”. 20. With “Press” the function “SetBit” should run. 21. Select the PLC tag “START_1“for the function. .

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 27

Exercise: First HMI project in TIA Portal Hands-on

22

23

Page 28

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: 22. Select in the task card “Events” the event “Release”. 23. With “Release” the function “ResetBit” should run. Select for the function the PLC tag “START_1“.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 28

Exercise: First HMI project in TIA Portal Hands-on

25 26 27

Page 29

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Create a button to stop the Output “Drive_1“.

What to do: 24. Copy the button “START_1“ and rename it to “STOP“. 25. Select the button and select in the inspector window the task card “Properties”. 26. Select the task card “Events”. 27. Attach the PLC tag “STOP” to the event “Press”.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 29

Exercise: First HMI project in TIA Portal Hands-on

28

Page 30

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: 28. Attach the PLC tag “STOP” to the event “Release”.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 30

Exercise: First HMI project in TIA Portal Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration

29

IECPL-Exercise: Programming

30 31

Page 31

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Showing the cross-reference in TIA Portal

What to do: 29. Choose in your screen the I/O field for the variable “Drive_1”. 30. Select the task card “Info” in the inspector window. 31. Choose the “Cross-reference” task card. Result:

All locations for the selected variable are then shown.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 31

Exercise: First HMI project in TIA Portal Hands-on Basics: PLC exercise

33

Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

32

Page 32

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Start the HMI simulation

What to do: 32. Choose the screen “Drives” in the project tree. 33. Start the simulation using the button “Start simulation”.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 32

TIA Portal V11 – Exercises

ƒ Basics: PLC exercise ƒ Basics: HMI exercise ƒ Exercise: Hardware Configuration ƒ IECPL-Exercise: Programming

For internal use only / © Siemens AG 2010. All Rights Reserved.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 33

Hardware- and Network Editor Exercise with S7-1200: Create New Project Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Hands-on

Page 34

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: „ Create a new project with the Project > New menu „ Name the project “S7-1200_Hands-on“ „ Select “Add new device”

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 34

Hardware- and Network Editor Exercise with S7-1200: Insertion of Unspecified CPU and HW Detection Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Hands-on

Page 35

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: 1. Insert a PLC > SIMATIC S7-1200 > CPU > Unspecified CPU 1200 > 6ES7 2XXXXXX-XXXX 2. Upload the hardware configuration from the connected S7-1200 3. Select the S7-1200 from the list of accessible devices 4. Double-check the transferred hardware configuration with that of your S7-1200 demo case 5. Select the CPU and change the PLC name under the properties 6. Select the SM1234 and in the properties set the following: 1. Analog Inputs > Channel0 – Measurement Type to +/- 5V 2. Analog Outputs > Channel0 – Analog Output Type to Current 7. Change to the Network view

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 35

Hardware- and Network Editor Exercise with S7-1200: Engineering an ET200S Station Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Hands-on

Page 36

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: „ Distributed I/O > ET200S > Interfacemodule > PROFINET > IM151-3 PN > 6ES7 1513BA23-0AB0 with FW Version 6.1 „ Distributed I/O > ET200S > Interfacemodule > PROFINET > IM151-3 PN > 6ES7 1513BA23-0AB0 with FW Version 6.1 „ Select the ET200S and change the name under properties „ Connect the PLC and ET200s with a PROFINET IO-SYSTEM „ Change to the device view for the ET200s „ Insert PM > PM-E DC24V > 6ES7 138-4CA01-0AA0 in Slot 1 „ Insert DI > 4DI x DC24V HF > 6ES7 131-4BD01-0AB0 in Slot 2 „ Insert DI > 4DI x DC24V HF > 6ES7 131-4BD01-0AB0 in Slot 3 „

Insert DO > 4DO x DC24V / 0,5A ST > 6ES7 132-4BD02-0AA0 in Slot 4

„

Insert DO > 4DO x DC24V / 0,5A ST > 6ES7 132-4BD02-0AA0 in Slot 5

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 36

Hardware- and Network Editor Exercise with S7-1200: Load the HW-Configuration Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Hands-on

Page 37

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: „ Change to network view, select the PLC and activate the context menu with the right mouse button „ Select Compile > Hardware configuration „ Select Download to device > Hardware configuration „ Configure your PG/PC-interface in the “Extended download to device” dialog „ Check “Show all accessible devices”, if the CPU cannot be reached „ Select the S7-1200 CPU „ Click “Load” „ Click “Load” in the “Load preview” dialog „ In the “Load results” dialog, select “Start All” and click “Finish”

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 37

Hardware- and Network Editor Exercise with S7-1200: Assigning a Device Name Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Hands-on

Page 38

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

What to do: „ Activate the PROFINET Subnet’s context menu by clicking with the right mouse button „ Select “Assign name” „ Configure the PG/PC-interface „ Search for accessible devices in the network „ Choose ET200S from the DropDown list and select the IM151-3 from the list of accessible devices „ Click “Assign name”

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 38

TIA Portal V11 – Exercises

ƒ Basics: PLC exercise ƒ Basics: HMI exercise ƒ Exercise: Hardware Configuration ƒ IECPL-Exercise: Programming

For internal use only / © Siemens AG 2010. All Rights Reserved.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 39

Exercise: Creating Hardware configuration Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Page 40

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Create a new STEP 7 project and add a new device to the project.

What to do: 1. Create a new project. 2. Add a new PLC station. 3. Create the hardware configuration (only for the central rack) 4. Download the hardware configuration

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 40

Exercise: Creating tags Hands-on

Page 41

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Create new tag tables with tags inside.

What to do: 1. Create four new tag tables and move them to the shown folders. 2. Create new tags in the tag tables as shown above.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 41

Exercise: Create a new function block in LAD Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Page 42

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Create a new function block (FB) with the language LAD.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 42

Exercise: Programming the FB in LAD Hands-on

Page 43

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Program the FB as shown above.

What to do: 1. Create the interface of the FB, as shown above. 2. Insert the shown program to the FB.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 43

Exercise: Calling the FBs in OB 1 Hands-on

2x

Page 44

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Call the FB twice in the OB 1 an connect the inputs and outputs as shown above.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 44

Exercise: Downloading the program Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Page 45

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Download the program to the PLC

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 45

Exercise: Block monitoring Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Page 46

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Monitor the FB and change the call environment.

What to do: 1. Open the FB and start monitoring. 2. Change the call environment (switch between instance DBs) 3. IMPORTANT: To change the call environment in this beta version you have to follow these steps: 3.1 If a message occurs, that the block cannot be monitored, close this message. 3.2 Activate the test mode manually via: “Testing” task card Æ Breakpoints Æ test mode 3.3 Start monitoring again.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 46

Exercise: Watch table Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Page 47

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Task: Create a new watch table and insert the content of the instance DBs. What to do: 1. Create a new watch table. 2. Drag and drop the content of the instance DBs for Engine 1 und 2 to the watch table 3. Start monitoring 4. Modify the „Speed“ tags.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 47

Exercise: Forcing inputs and outputs Hands-on Basics: PLC exercise Basics: HMI exercise Exercise: Hardware Configuration IECPL-Exercise: Programming

Page 48

Task:

Exercises for TIA Portal V11 (Micro Automation)

For internal use only / © Siemens AG 2010. All Rights Reserved. I IA AS CS2 FA

Open the forcing table and force I1.0 and Q0.1 to “TRUE”.

What to do: 1. Open the forcing table 2. Insert two new lines for I1.0:P und Q0.1:P an. 3. Set the forcing values to “TRUE” 4. Activate forcing.

SIMATIC Systems Support I IA AS CS 2 FA

TIA Portal V11 Seite / page 48

Thank you for your attention!