COOPER LIGHTING - METALUX

Specifications and dimensions subject to change without notice. ABI Cooper Lighting recommends the following lamp operation when 4...

8 downloads 703 Views 130KB Size
COOPER LIGHTING - METALUX

®

DESCRIPTION

The Arctic Bay Series is designed as a high efficiency solution to sub-zero ambient environments found in cold storage and refrigerated facilities. The Arctic Bay has been optimized to provide maximum performance with lamp and ballast systems that tolerate colder ambient temperatures. Primary applications include cold storage, refrigerated facilities and environments with ambient temperatures as low as -20°F.

Type

Catalog # Project

Date

Comments Prepared by

S P E C I F I C AT I O N F E AT U R E S

Application The Arctic Bay Series high lumen package allows for the benefits of fluorescent lighting to be applied at high mounting heights that were traditionally exclusive to H.I.D. These benefits include exceptional color rendering, high system efficacy, 95% lumen maintenance, long lamp life, instant on, optional dimming, and uniform brightness control.

E l e c t ri c a l * Class P ballast, rated for -29°C to 90°C operation, wired to rotor locked sockets. Optional passive infra-red motion sensor is rated for high humidity, low temperature application. Sensor provides 1400 sq. ft. of coverage in mounting heights up to 40'. See control chart options at ambient temperatures below 32˚F. UL/CUL listed and suitable for damp location.

C o n s t ru c t i o n Housing, end plates and socket tracks are die formed cold rolled steel. Die formed internal reflectors are available in either a high reflectance specular material or a painted white polyester powder coat finish. A sealed and gasketed door frame in a clear or prismatic A12 pattern lens provide for a thermal environment for optimal lamp operation.

Finish Electrostatically applied baked white polyester powder coat finish is preceded by a multistage cleaning cycle, iron phosphate coating with rust inhibitor.

Optics Die formed, segmented optical design optimizes performance across three distributions. Optical choices include a narrow distribution for aisles, medium distribution for assembly and loading areas, or wide distribution for general, open area lighting. Mounting The fixture is suited for surface and suspension mounting with optional wire hook and chain set, HB-SPM or cable mounting.

ARCTIC BAY SERIES 17" X 48" 4, 5 AND 6 LAMP

Cold Storage High-Bay Industrial Luminaire

4-5/16" [109mm]

E N E R G Y D ATA 16-3/4" [427mm]

L A M P C O N F I G U R AT I O N S

Input Watts (@ 277V): EB Ballast 454=229W 554=300W 654=346W

D I M E N S I O N TO P V I E W

Luminaire Efficacy Rating LER = FI-54 Catalog Number: ABI-654T5-UNVEBT2-U Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $5.08

7/8" [23mm] K.O. 1/2" [13mm] K.O.

4 LAMP 4-5/16" [109mm] X=3-1/2" [89mm]

X X X 16-3/4" [427mm]

7/8" [23mm] K.O. 1/2" [13mm] K.O

5 LAMP

48-1/8" [1222mm]

4-5/16" [109mm] X=2-13/32" [61mm]

16-3/4" [427mm]

X

Y

Y

*Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. ** Consult Pre Sales Technical Support.

X

16-3/4" [427mm]

Y=2-25/32" [70mm]

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS 7/8" [23mm] K.O. 1/2" [13mm] K.O

6 LAMP 4-5/16" [109mm] X=1-1/8" [28mm]

Safe and convenient means of disconnecting power. Y

Y X Y

Y

16-3/4" [427mm]

Y=2-13/32" [61mm]

Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes.

ADF071257 2012-01-31 13:20:58

ABI

P H OTO M E T R I C S ABI-654T5-UNV-EBTL2-U

Electronic Ballasts (6) F54W T5HO lamps 26400 lumens Spacing criterion: (II) 1.1 x mounting height, (⊥) 1.2 x mounting height Efficiency 65.1% Test Report: 2AB-654T5-UNVEBT2.IES LER =FL59 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.06

Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

Along II 9670 9568 9513 9020 8661 7923 6907 6251 5582 5059 4194 3551 2901 2245 1665 1116 605 233 31

Across ⊥ 9670 9524 9324 8718 8137 7197 5917 5059 4188 3538 2863 2384 1968 1545 1192 845 504 233 63

45° 9670 9543 9400 8844 8377 7588 6497 5809 5071 4466 3614 2952 2352 1778 1305 864 473 195 50

C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

78 69 61 54 48 44 40 36 33 31 29

78 66 57 49 43 38 34 31 28 26 24

78 64 53 45 39 34 30 27 24 22 20

76 70 64 59 54 50 47 43 41 38 36

76 67 59 53 48 43 39 36 33 30 28

Candela

Electronic Ballasts (6) F54W T5HO lamps 26400 lumens Spacing criterion: (II) 1.1 x mounting height, (⊥) 1.2 x mounting height Efficiency 69.5% Test Report: 2AB-654T5-CL.IES LER =FL63 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.81

Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

Along II 8130 8092 7982 7798 7538 7204 6794 6317 5776 5168 4500 3783 3030 2261 1517 848 335 66 0

Across ⊥ 8130 8289 8398 8179 7685 6844 5568 4145 3469 3096 2708 2344 2089 1928 1760 1077 501 106 0

45° 8130 8204 8279 8200 7895 7423 6751 5832 4601 3415 2812 2371 1925 1545 1251 1031 487 108 0

C o e f fi c i e n t s o f U t i l i z a t i o n

Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 78 71 66 60 56 51 48 45 42 39 37

ABI-654T5-CL-UNVEBTL2-U

76 65 56 48 43 38 34 31 28 25 23

76 63 53 45 39 34 30 27 24 22 20

20% 50% 50 30 10

30% 50 30 10

50

72 64 57 51 46 42 38 35 32 30 28

69 62 55 49 44 40 37 34 31 29 27

66 60 53 48 43 39 36 33 30 28 26

72 63 54 47 42 37 33 30 27 25 23

72 61 51 44 38 34 30 27 24 22 20

69 60 52 46 41 36 33 30 27 25 23

69 59 50 43 38 33 30 27 24 22 20

Zonal Lumen Summary

Luminance Data

Zone 0-30 0-40 0-60 0-90 0-180

Angle in Deg 45 55 65 75 85

Lumens

%Lamp

%Fixture

6856 10426 16414 19532 19532

22.9 34.8 54.7 65.1 65.1

35.1 53.4 84.0 100.0 100.0

Average 0-Deg cd/sm 11513 9962 8548 6939 4302

Average 45-Deg cd/sm 10163 8282 6770 5372 3600

ABI-454T5-CL-UNVEBTL1-U

Candela

(2) Electronic Ballasts (4) F54W T5HO lamps 26400 lumens Spacing criterion: (II) 1.1 x mounting height, (⊥) 1.0 x mounting height Efficiency 62.8% Test Report: AB-454T5-CL.IES

Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

LER =FL58 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.13

Along II 5741 5782 5778 5547 5531 5186 4798 4329 3989 3099 3120 2560 1999 1461 949 495 178 32 0

10% 30 10 66 58 51 45 40 36 32 29 27 25 23

0% 0

66 57 49 42 37 33 29 26 24 22 20

65 56 48 41 36 32 28 25 23 21 19

Average 90-Deg cd/sm 8051 6688 5883 5254 4302

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 83 76 70 64 59 55 51 47 44 42 39

83 73 65 58 52 47 42 39 35 33 30

83 71 60 52 46 41 36 33 30 27 25

83 68 57 48 42 36 32 29 26 24 22

81 75 68 63 58 53 50 46 43 41 38

81 72 64 57 51 46 42 38 35 32 30

81 81 69 67 60 56 52 48 45 41 40 36 36 32 33 29 30 26 27 24 25 21

20% 50% 50 30 10

30% 50 30 10

50

77 69 61 55 49 44 40 37 34 31 29

74 66 59 53 47 43 39 36 33 31 29

71 64 57 51 46 42 38 35 32 30 28

77 67 58 50 44 39 35 32 29 27 25

77 65 55 47 41 36 32 28 26 23 21

74 65 56 49 43 39 35 32 29 26 24

74 63 54 46 40 35 32 28 26 23 21

Zonal Lumen Summary

Luminance Data

Zone 0-30 0-40 0-60 0-90 0-180

Angle in Deg 45 55 65 75 85

Lumens

%Lamp

%Fixture

6390 9871 15445 18344 18344

24.2 37.4 58.5 69.5 69.5

34.8 53.8 84.2 100.0 100.0

Average 0-Deg cd/sm 11454 10336 8384 5135 1187

Average 45-Deg cd/sm 7569 6478 5729 6243 1942

10% 30 10 71 62 55 48 43 38 34 31 28 26 24

71 61 52 45 40 35 31 28 25 23 21

0% 0 69 60 51 44 38 34 30 27 24 22 20

Average 90-Deg cd/sm 6862 6404 7149 6521 1906

Across ⊥ 5741 5670 5407 8718 5110 4312 3272 2463 1973 1466 1487 1309 1256 1148 792 463 102 21 0

45° 5741 5745 5649 5390 5385 4959 4301 3428 2711 1720 1595 1282 1035 851 733 452 183 26 0

C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 75 70 65 60 56 51 48 44 41 38 36

75 67 61 55 49 44 40 37 33 30 28

75 65 57 50 45 39 35 32 28 25 23

75 63 54 47 41 36 32 28 25 22 20

73 68 63 59 54 50 47 43 40 37 35

73 66 59 54 48 44 40 36 33 30 27

73 64 56 50 44 39 35 32 28 25 23

73 62 53 46 41 35 32 28 25 22 20

20% 50% 50 30 10

30% 50 30 10

50

70 63 57 52 47 42 39 35 32 29 27

67 61 55 50 46 41 38 34 31 29 26

64 59 53 49 44 40 37 34 31 29 26

70 62 55 48 43 38 34 31 28 25 23

70 60 52 46 40 35 31 28 25 22 20

67 60 53 47 42 38 34 31 28 25 22

67 59 51 45 40 35 31 28 25 22 20

Zonal Lumen Summary

Luminance Data

Zone 0-30 0-40 0-60 0-90 0-180

Angle in Deg 45 55 65 75 85

Lumens

%Lamp

%Fixture

4324 6484 9542 11049 11049

24.6 36.8 54.2 62.8 62.8

39.1 58.7 86.4 100.0 100.0

Average 0-Deg cd/sm 11064 11265 8725 4832 917

Average 45-Deg cd/sm 6138 5642 5082 4411 765

10% 30 10 64 58 52 46 41 37 33 30 27 24 22

64 57 50 44 39 34 31 28 25 22 20

0% 0 63 56 49 43 38 33 30 26 23 21 19

Average 90-Deg cd/sm 5233 5762 6854 4514 612

Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801

ADF071257 2012-01-31 13:20:58

ABI

Thermal Performance Cooper Lighting thermally tested each configuration to determine the optimal luminaire operating temperature range. When specifying luminaires use the lowest temperature the luminaire will be exposed to during operating hours. Facility temperatures fluctuate and luminaires exposed to temperatures less than stated are not recommended. Freezer Temperature Ranges To maximize energy efficiency, some facilities will operate chillers only during off-peak 40 ft. hours. In this case the facility will chill the space to temperatures as low as -40°F (-40°C) to maintain the targeted temperature during operating hours. Fluorescent luminaires 35 ft. @ -40°F (-40°C) exposed to -40°F (-40°C) temperatures are not recommended. Energy efficient HID 30 ft. sources may be a better alternative. 20 ft.

10 ft.

Temperature Control Capability

20 ft. @ -20°F (-29°C)

10 ft. @ -10°F (-23°C)

Cooper Lighting recommends the following lamp operation when implementing a control system in colder ambient environments. Arctic Bay (ABI) Series -20°F (-29°C) – 0°F (-18°C)

Motion Sensor Options (# of Lamps Controlled)

Fixture

# Lamps

Lamp Type

ABI-454T5

4 Lamp

T5HO

Not Recommended

2

ABI-554T5

5 Lamp

T5HO

Not Recommended

2

ABI-654T5

6 Lamp

T5HO

Not Recommended

2

0°F (-18°C) – 32°F (0°C)

Routine Use

Occasional Use (3)

Motion Sensor Options (# of Lamps Controlled)

Fixture

# Lamps

Lamp Type

Routine Use (1)

Occasional Use (2)

ABI-454T5

4 Lamp

T5HO

2

ALL

ABI-554T5

5 Lamp

T5HO

2

2

ABI-654T5

6 Lamp

T5HO

2

4

32°F (0°C) – 50°F (10°C)

Motion Sensor Options (# of Lamps Controlled)

Fixture

# Lamps

Lamp Type

Routine Use (1)

Occasional Use (2)

ABI-454T5

4 Lamp

T5HO

2

ALL

ABI-554T5

5 Lamp

T5HO

2

3

ABI-654T5

6 Lamp

T5HO

2

4

NOTES: (1) Luminaire achieves 40% or greater of relative light output at the indicated temperature in under 60 seconds. (2) Luminaire achieves 40% to 80% of relative light output at the indicated temperature in under 7 minutes. (3) Greater than 20 min. lamp options.

Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801

ADF071257 2012-01-31 13:20:58

ABI

O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : ABI-654T5-UNV-EBT2-MS/OB-U

Series ABI=Arctic Bay No. of Lamps 4=4 Lamps 5=5 Lamps 6=6 Lamps Lamp Type 49T5=49W T5HO Lamps (48") 51T5=51W T5HO Lamps (48") 54T5=54W T5HO Lamps (48") Distribution N=Narrow Beam (Standard) M=Medium Beam W=Wide Beam

Includes V Hangers for rapid installation

Shielding Blank=Prismatic Acrylic Lens w/Gasketed Door Frame CL=Clear Acrylic Lens w/Gasketed Door Frame

Ballast Type EBTL =T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% Minimum Start Temp. -20°F (-29°C) No. of Ballast 1, 2 or 3

Voltage (1) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt

Options C3=3' White Cord Fixture Attached C6=6' White Cord Fixture Attached MS/OB=360° or 180° Motion Sensor Installed, Inner 2 Lamps Constant On (4L, 5L) (2) Inner 4 Lamps Constant On (6L) (2) MS/IB=360° or 180° Motion Sensor Installed, Outside Lamps Constant On (2) PC3-Voltage=3' Cord/Plug Fixture Attached(1) PC6-Voltage=6' Cord/Plug Fixture Attached(1)

Options Lamps Installed L5830=T5 Lamp, 85CRI 3000K L5835=T5 Lamp, 85CRI 3500K L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency installed (1)

Packaging U=Unit Pack PAL=Job Pack Out of Carton PALC=Job Pack In Carton Accessories (order separately) HBAYC-CHAIN/SET/U=(2) V-Hook Hanger, 36" Chain Sets w/S-Hooks HB-SPM=Single Monopoint Hanger w/Hub RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop Y-TOGGLE=Y Mounting Toggle, #2 Cable (Specify 10' or 30')

NOTES: (1) Voltage must be specified when ordered with plugs or emergency ballasts. ballast as UNV (120V-277V), 347V or 480V.

(2) Specify

voltage of

Accessories (order separately) HBAYC-CHAIN/SET/U=(2) V-Hook Hanger, 36" Chain Sets w/S-Hooks HB-SPM=Single Monopoint Hanger w/Hub RH-1=Retrofit Hanger FH-1=Fixture Hook =Fixture Loop Y-TOGGLE=Y Mounting Toggle, #2 Cable (Specify 10' or 30')

S H I P P I N G DATA Catalog No. ABI-454 ABI-554 ABI-654

Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801

Wt. 25 lbs. 25 lbs. 27 lbs.

ADF071257 2012-01-31 13:20:58